argument
Brand: GE
Model: IC754VSI12CTD
Screen size: 12 inches
Resolution: 1024 x 768
Screen type: Color TFT
Operating voltage: 12 or 24V DC
Power consumption: Lower than 48W
Storage capacity: 128 MB
Processor: 1GHz ARM Cortex-A8
Operating system: Microsoft Windows CE 6.0
specification
Communication interface: RS232, RS485, Ethernet
I/O options: Support for a variety of standard ports and expansion buses
Memory type: including SRAM, etc., used to store user data
Firmware updates: Available for download from the support website
Size and weight
Dimensions: 16 x 14 x 8 inches (or 8 x 14 x 16 inches, depending on the source)
Weight: 10 pounds
Parameters and specifications
Brand and Series: The DKC is one of Rexroth’s series of AC servo motors designed to meet the needs of precise motion control.
Power and Performance:
“040” usually refers to the rated power or size range of the motor.
The rated current is 40A.
The nominal voltage of the DC bus is DC 700V.
Version 1 and comes with standard firmware.
Technical specifications: Specific technical specifications, including the torque, speed, voltage, current and other parameters of the motor, are crucial for users to choose the right product. This information can usually be found in the official manual or technical manual of the product.
Rated voltage: It is said to be 24V
Parameters
The specific parameters of the WR-D4004 may vary depending on the manufacturer or application scenario. But in general, it may include:
Output frequency: 60Hz
Voltage: 240VDC for example
Temperature range: e.g. 1000 ° C
Frequency response: 3khz
argument
Model: IC695CPU315-CD
Compatibility: GE Fanuc series 90-30 PLC
Power supply: 24V DC
Communication interface: Ethernet, RS-485, RS-232
Memory: 64KB RAM and 1MB Flash
Processor speed: 100MHz
I/O points: up to 4096
Operating temperature: -40°C to 70°C
LD instruction processor: hard PLC
I/O operation speed: up to 32K times per second
Boolean execution speed: 0.047 milliseconds per 1000 Boolean instructions
argument
Maximum output current: 1.5A/ phase
Power input: DC 15V to 36V, 2.5A MAX; In some configurations, the input voltage ranges from 48 to 57VDC
Excitation current range: (L excitation)0.3 to 1.5A/ phase, (H excitation)0.15 to 0.75A/ phase
Drive system: Chopper Constant current Pentagonal connection (H/L)
Number of splits: Microsteps: 1 to 100 splits
Input and output signals: CW, CCW input, optical coupler input; Pulse width more than 1μs; L=0 ~ 0.5V, H=4 ~ 5V
specification
Power failure alarm: The alarm can be output through the relay
Communication protocol: Compatible with EtherNet/IP, Profinet, EtherCAT, CC-Link IE and DNP 3.0 and other industrial communication protocols
Compliant with IEEE 802.3at standard, power supply up to 30 watts per port, and backward compatible with IEEE 802.3af standard
Size and weight
Dimensions: Approximately 144.3mm (H) x 26.1mm (W) x 94.9mm (D)
Weight: 390g
1. Parameters
Input: Turbine Sensor PR6422/… ~ PR6426/…
Output: The AC voltage signal superimposed on the DC voltage is proportional to the shaft vibration
Output voltage linear range: -4… -20V (supply voltage is -24V); Wide range: -1… -22V; Specific output: -12V (symmetrical measurement range at both ends)
Internal resistance: 100kΩ
Response time: 15
Accuracy: The linear error depends on the connected sensor model, for example, the connected sensor PR6422 ≤1.5%, PR6423 ≤1.0% ≤2%, PR6424 ≤1.5% ≤2%, PR6425 ≤6.0%
Temperature drift: zero 200mV/100K; Sensitivity <2%/100K
Time drift: greater than 0.3%
Error of supply voltage: <0.2%/V
1. Parameters
Type: Fieldbus network multiplexer receiver, security gate and isolator
System capability: strong
System function: strong
Operating system: Simple
Features: Communication module
Bom number: MTL838C
Color: Black
Specification: 121212 (may refer to a certain size, but the specific meaning needs to be further confirmed)
Output frequency: 230 (unit unclear, may refer to some specific output parameter)
2. Specifications
As a multiplexer receiver, the MTL838C has the ability to convert multiple signal sources into a single bus signal and is often used in complex industrial field network environments.
It is often designed with safety and isolation in mind to protect systems and equipment from electrical noise, grounding loops, and other issues.
argument
Rated voltage: 380V±10%, 3 phase 4 line
Ambient temperature: -25℃ to 50℃
Relative humidity: <95%
Altitude: <2000 m
Total compensation: 24-300kvar
Applicable transformer capacity: 80-1000KVA
Control power input: Accept 90 to 300V DC, 70 to 265V AC
1. Parameters
Power supply voltage: up to 80V DC
Maximum driving current: 6.0A per phase
Communication protocols: Support Modbus, IEC 61850, DNP3, IEC 60870-5-103 and other communication protocols
Support standards: IEC61850 communication standards are supported, including redundant HSR and PRP, GOOSE and IEC61850-9-2
Time protocol: Support IEEE 1588 v2 high precision time protocol
2. Specifications
Type: split-phase double-ended line differential protection and control relay
Applications: Suitable for utility and industrial distribution systems, including radial, ring and mesh distribution networks, with or without distributed generation
Communication mode: Communication between substations through fiber optic link or current guide line connection
Communication interface:
With two Ethernet communication ports, support 10/100 Mbps data rate, the physical interface is RJ45.
One RS232 port and one RS485 port.
A station manager port.
Supported Ethernet-based protocols include SRTP, Modbus TCP server and client, and Ethernet Global Data (EGD).
Serial based protocols supported are Modbus RTU slave station, SNP, serial I/O.
1. Parameters
Model: DSQC679 (sometimes also indicated as DSQC679 3HAC028357-001)
Brand: ABB
Operating voltage: 38V (also known as 24V)
Processing speed: 220μs
Output frequency: 24Hz
Data capacity: 20
Program capacity: 20
Ambient temperature: up to 80℃
2. Specifications
Installation mode: Other
Structure: modular
I/O count: 20LD
Instruction processor: hard PLC