argument
Output voltage:
24VDC (in some cases)
5V DC (in another case, for GE Fanuc 90-70 series)
Maximum output current:
10A (in some cases)
0.5A (in another case, per channel)
Operating temperature range:
-40℃ ~ +85℃ (in some cases)
0 ° C ~ 60 ° C (in another case, for GE Fanuc 90-70 series)
Input channels: 8 (in some cases)
Max I/O points: 384 (in some cases)
Communication protocols: Modbus, Ethernet, OPC (in some cases)
specification
Product Family: GE digital output module, possibly belonging to GE Fanuc 90-70 series
Output type: PNP (in certain cases)
Electrical isolation: Each channel has electrical isolation
Redundancy: Dual power supply and processor (in some cases)
Number of ports: There are usually multiple network ports, including Ethernet ports and fiber ports, and the number of ports is between 8 and 16 ports.
Port speed: Different speeds, such as Gigabit Ethernet (1Gbps) and Fast Ethernet (100Mbps), are supported to meet the connection needs of different devices.
Optical fiber support: Includes optical fiber ports, which can be used for long-distance connections, such as connecting networks between different equipment rooms.
Stack function: Supports the stack function, allowing multiple switches to form a logical unit to simplify management and improve availability.
VLAN support: Supports virtual local area network (VLAN) configuration, allowing network administrators to divide the network into multiple logical networks to enhance network security and performance.
QoS Support: Supports quality of service (QoS) features that allow network administrators to assign bandwidth and priority to different data streams to ensure good performance for critical applications.
specification
Device type: common switch.
Transfer rate: 100Mbps, but Gigabit Ethernet may also be supported.
Transmission mode: full/half duplex adaptive.
Backplane bandwidth: A2H124-24FXGB Number of modular slots 5.
Power supply: Dual power supply redundant input, DC(9-36)V, typical DC24V, power consumption less than 4W, with DC1500V voltage isolation and reverse protection function.
Power fault alarm output: Fiber link fault and power fault alarm output, contact capacity: DC48V/1A.
Operating temperature: -10-70 °C (otherwise known as -10 ~ 60 °C), storage temperature range of -40 ~ 85 °C.
Relative humidity: ≤90% (no condensation).
Output current: Digital output and alarm output current up to 200 mA/ channel.
specification
Communication interfaces and protocols: Support a variety of communication interfaces and protocols for data exchange and communication with other devices or control systems.
Programmability: Some modules may be programmable, allowing users to customize the logic and functionality of the input and output as needed.
I/O storage capacity: up to 32K bits of discrete input and output signals (%I and %Q), and 32K words of analog input and output capacity
Block support: Up to 512 blocks are supported, each block up to 128 KB
Power requirements: 3.3 volts DC, 5 volts DC or 24 volts DC
specification
Communication interface:
Two serial ports (RS-232 and RS-485)
Embedded Ethernet interface, support SRTP protocol, data transfer rate of 10/100 Mbaud
Supports a variety of communication protocols, such as Modbus RTU Slave, SNP, Serial I/O, PROFINET, EGD, Modbus TCP server and client, Genius, Profibus DP, etc
Programming support: Compatible with several IEC languages as well as the C programming language, you can program using ladder, structured text, C or function block diagram programming languages
Scalability: Supports a maximum of eight local racks
argument
System power supply voltage range: 20 to 32V dc
Number of inputs: 40 channels
Input current range: 0-22mA
Input voltage range: 0-6 Vdc
Sample update time: 0.5 ms
Resolution: 3.9 microamps (1/256 mA)
Safety accuracy: +/ -1% of full scale (default threshold, above which 0x70nn series differential fault will occur)
Calibration accuracy: 0.03%
Recommended input channel calibration check interval: 2 years
Circuit type: Fault tolerant, full triple optional line monitoring
Power consumption: 15-18W
Self-check interval: 2 minutes
Operating temperature: -5 ° C to 60 ° C (23 ° F to 140 ° F)
Non-operating temperature: -25 ° C to 70 ° C (-13 ° F to 158 ° F)
Operating humidity: 10-95%RH Non-condensing