In addition, some information indicates that the use of the LYD105A involves automatic voltage regulation with a range of 110-221 and an accuracy of 0.1-1.1, but please note that these parameters may vary depending on the specific model or application scenario.
Full leakage current measurement range (peak) : 0-20mA
System measurement accuracy: ±(reading ‘5% ± 1 word)
AC charging: AC 220V ±10%, 50Hz ±1%
Battery continuous working time: more than 8 hours
Battery charging time: more than 6 hours
specification
Measurement parameters: including arrester leakage current Full current (including harmonics), leakage current resistance component (including harmonics), resistive current peak, full current peak, operating (or test) voltage value (including harmonics) and arrester power consumption
Rated voltage: The specific parameters are not directly given, but according to similar products, it may cover a variety of voltage levels, need to refer to the specific model or data table.
Rated current: Again, specific parameters are not given directly and may vary depending on the model.
Rated frequency: Not given directly, but usually matches the standard frequency of the power system, such as 50Hz or 60Hz.
Operating temperature: In the range of -20°C to +50°C (according to some information), which may vary depending on the model or environmental requirements.
Ac/DC power supply: The input voltage range is usually 12-48VDC (according to some sources) for power supply.
specification
IEC61850 communication protocol support: This is an international standard widely used in substation automation for efficient communication between equipment.
argument
Voltage: 24V (according to some information)
Current: 100-400A (according to some information)
Rated frequency: User can choose 50/60 Hz
specification
Protection functions: including three-phase thermal overload protection, three-phase overcurrent protection, three-phase short-circuit protection, non-directional grounding fault protection, three-phase unbalance protection, reverse phase protection, etc
Communication protocols: Support communication protocols such as SPA bus, IEC 60870-5-103 and Modbus (RTU and ASCII)
Size and weight
Size: The specific size is not directly given, but depending on the type of relay, it is generally more compact and suitable for a variety of installation environments.
Weight: Approx. 2KG (according to some information)
argument
Number of channels: 16 (including digital input, analog input, digital output, analog output)
Safety level: SIL 3
Power supply voltage: 24V DC
Operating temperature: -40℃~85℃
specification
Product type: Secure I/O module
Isolation mode: photoelectric isolation
dimension
Dimensions: 170mm x 100mm x 60mm
argument
Power: Usually associated with the “040” in the model number, which may indicate a rated power or size range.
Rated current: 40A.
DC bus nominal voltage: DC 700V.
Version: The version of the servo drive is 1.
Firmware: Comes with standard firmware.
Speed response frequency: 1000KHz (Note: This parameter may be related to a specific application or configuration and may vary from data to data).
Rated voltage: 24V.
specification
Type: AC servo motor.
Function: Power servo.
REM610 parameters may include electrical parameters such as voltage and current, as well as Settings for protection functions. Specific parameters such as voltage 24V, current range 100-400A (these parameters may vary by product model and configuration).
specification
The REM610 is a multifunctional protective relay based on a microprocessor environment with a self-monitoring system that continuously monitors the operation of the relay.
It provides a series of integrated protection functions, such as three-phase thermal overload protection, three-phase overcurrent protection, three-phase short-circuit protection, etc.
argument
Control mode: PID control, fuzzy control, adaptive control
Input signal: analog (0-10V, 4-20mA), digital (ON/OFF)
Output signal: analog (0-10V, 4-20mA), digital (ON/OFF)
Control accuracy: ±0.1%FS
Communication interface: RS485, Modbus, Profibus
Operating temperature: -10℃~+55℃
Supply voltage: AC220V/DC24V
Voltage range: 0 ~ 5V, 1 ~ 5V (load resistance ≥200KΩ)
specification
Type: Universal controller or servo drive module
Design: Modular design can be flexibly expanded and applied to various industrial control fields
Features: Programmable, high precision, high reliability
argument
Memory capacity: 128 MB reflected memory capacity.
Network transfer rate: The maximum network transfer rate can reach 2.1 GB per second.
Design transmission speed: Fiber optic network design transmission speed of up to 2.12 Gbaud.
Power requirements: 580 mA@3.3VDC and 220 mA@5VDC.
specification
Interface: Requires LC connector.
Compatibility: Compatible with VMIC 5565 series reflective storage devices.
Function: As a node on a reflective memory network or as a dedicated link in a redundant system with hot standby cpus.
Parameters and specifications
Model: PR6423/003-030
Brand: Emerson EPRO (There is also information that the manufacturer may be German EPRO)
Uses: Sensors, especially vibration sensors, used to measure the vibration of machinery
Installation: Simple
Sensitivity: High
Structure: Strong
Operating temperature: up to 200°C
Measuring frequency range: 10… 1000Hz and 4… 1000Hz
Probe length: 55mm (for PR6423/003-030)