Protocol support: Modbus Plus and possibly other industrial communication protocols such as Modbus and Ethernet /IP.
Ports: Supports two logically independent Modbus Plus buses, and provides one or two Modbus Plus electrical ports and one or two 155M optical fiber ports.
Transmission rate: up to 155Mb/s, communication speed up to 1MB.
Protection class: IP30.
Power supply: DC9-36V wide redundant dual power supply, DC1500V power isolation, reverse protection.
Input/output function: The module can receive digital or analog signal input from various sensors or devices, such as temperature, pressure, flow, etc., and control various actuators or devices, such as electric valves, motors, lights, etc.
Data exchange speed: Possible support for high-speed data exchange, ensuring real-time monitoring and control.
Interface: May be equipped with a variety of communication interfaces, such as Ethernet, serial interface, etc., data communication and integration with other devices or control systems.
Programmability: The module may have a certain degree of programmability, and the user can configure the parameters and functions of the input and output channels according to the actual needs.
Function: Suitable for industrial automation, machine control, process control, etc
Communication function: Support a variety of communication protocols and interfaces, such as Ethernet, serial communication (such as RS-232, RS-485), CAN bus, etc
Performance characteristics: not only absorb the traditional DCS “centralized management, decentralized control” design essence, but also retain the traditional PLC inherent flexibility and bit advantages, suitable for discrete control, sequence control and continuous control occasions
Function: RDIO400 is an interface module between serial process bus (SPBus) and digital input or output signals. It provides a cost-effective solution for connecting any number of inputs and outputs to Kongsberg maritime automation systems, regardless of the distance between the remote device and the controller computer.
Input/Output:
Up to 32 independently defined digital input or output channels.
Digital input: The loop voltage is 24 VDC ± 20%, the maximum input voltage is equal to the loop voltage, and the input signal frequency can reach 10 millisecond pulses.
Digital output: The loop voltage is also 24 VDC ± 20%, the loop driver is 1 A, and the short-circuit high voltage side driver (HSD) is protected.
SPBus interface:
Dual serial process bus (SPBus) interface, allowing optional redundancy.
Each SPBus interface ensures electrical isolation from the control system.