Power supply: Wide range of power supply voltage, support 12~40V input voltage.
Output current: The output current can be set, up to 2A, and supports 8-level setting.
Chopper mode: The two-stage constant current chopper mode helps to provide stable current output, reduce fluctuations and noise during motor operation, and improve the stability and accuracy of the system. The chopper frequency is 20KHz.
Subdivision accuracy: Subdivision accuracy up to 16 level Settings, up to 256 subdivisions, meaning that the motor can achieve higher accuracy and smoother rotation during operation.
Protection mechanism: It has the function of power polarity misconnection protection and overcurrent protection to ensure that the motor and drive are protected from damage under abnormal conditions.
Output current range: 0~1A (but note that the CPS-150F control power supply is rated at 150A elsewhere, which may be for different types of power supplies or applications)
Power supply capacity: If referring to a control power supply, its “150” may indicate a rated current of 150A
Rated voltage: The CB801 is rated for 240/415V AC.
Rated current: The CB801 is rated from 0.5A to 63A.
Breaking capacity: The breaking capacity of the CB801 is 10kA.
Pole: CB801 is a single-pole circuit breaker.
Tripping characteristics: CB801 has B, C and D tripping characteristics.
Mounting type: CB801 is designed for DIN rail mounting.
Operating temperature: The CB801 can operate in a temperature range from -25°C to +60°C (although some descriptions mention -40°C to +85°C or -40°C to 70 °C).
Frequency: The frequency range of the CB801 is 50-60Hz.
Input signals: Accepts input signals from approach eddy current sensors, rotary position sensors (RPT), DC linear variable differential converters (DCLVDT), AC linear variable differential converters (AC LVDT) and rotary potentiometers
Measurement types: including axial (lateral) position, differential expansion, standard single bevel differential expansion, non-standard single bevel differential expansion, double bevel differential expansion, compensation differential expansion, shell expansion and valve position
Alarm point setting: The value measured by the monitor can be used as the alarm point, usually can be arbitrarily set in the range of 0 to 100% of the full scale of the respective measurement value
Type: Industrial automation control system PLC module
Features: With the microprocessor as the core, it has many characteristics of the microcomputer, but the working mode is very different from the microcomputer
Workload analysis: In order to evaluate the workload of the operator, a workload analysis is performed for all important functions. The analysis should be based on sequential accumulation of working hours. If the capability of the operator is verified, the working requirements of the hardware can be determined