argument
Measuring range: 0 to 100% RH (relative humidity)
Accuracy: ±2% RH at 25°C (77°F)
Repeatability: ±0.2% RH
Response time: 90% of the final value
Electrical connection: 1/2-14 NPT catheter
specification
Environment class: NEMA 4X, IP66, dust, water and other contaminants
Color: White
Output frequency: 220Hz
I/O count: 2048
specification
Function: Motor Protection series with optional metering function and 12 RTD inputs for protecting and controlling medium-sized motors and supporting motor equipment
Technical features: The use of ground overcurrent protection and start suppression technology to protect the motor and extend the life of the system
dimension
Approximate dimensions: 12 “high x 5” wide x 8 “long
weight
Approximate weight: 4.5 kg
argument
Communication protocol: Profibus DPV1 protocol is supported, and data transmission can be carried out through Class 1 or Class 2 DPV1 services.
Data processing capability: Using high-performance processor and memory, fast data calculation and processing, to meet the needs of complex control algorithms and data processing.
Maximum number of slaves: Up to 125 slave devices can be connected.
Maximum data: up to 1536 bytes of input and 1536 bytes of output data.
specification
Type: Single slot module with one RS485 optical isolation Profibus interface.
Backplane compatibility: Compatible with 1756 backplane.
specification
Shape: Compact, easy to install
Construction: Robust and reliable in harsh environments
Size and weight
Dimensions: Specific dimensions are not provided directly, but based on the general dimensions of industrial automation modules, it is assumed that they will not be too large to be easily inserted into the ControlLogix rack.
Weight: The specific weight is not directly provided, but it can also be inferred that its weight is moderate, easy to install and handle.
argument
Rated current: According to different data, the rated current is different, may be 20A, may also be 100-400A. Please note that this may refer to different configurations or versions.
Rated voltage: 240V AC, but it is also mentioned that the input voltage range is 12-48VDC.
Output voltage: 5VDC (within the input voltage range).
Output current: Max. 10A.
Accuracy: ±0.5%.
Operating temperature range: -25°C to +55°C, or -20°C to +70°C.
Storage temperature range: -40°C to +70°C.
argument
Input range: 0 ~ 4000 psi (about 0 ~ 275.8 bar)
Output range: 4 to 20 mA DC
Power supply mode: 12 VDC ~ 45 VDC (some say 12-48VDC)
Accuracy: +/ -0.1% of the range
Working temperature:
Operating temperature: -40°C to 85°C (also known as -20°C to +50°C)
Storage temperature: -40°C to +70°C
specification
Material: stainless steel (also known as ABS)
Process connection: 1/2 inch NPT
Electrical connection: 1/2 inch NPT catheter
argument
Working voltage: 24V DC
Operating temperature range: -20°C to +60°C
Communication interface: May be equipped with RS485 interface, electrically isolated, can be connected to the network, transmission protocol such as Profibus DP
Digital input channels: 4
Digital output channels: 4
Analog input channels: 1
argument
Payload: between 150 and 500kg (up to 650kg with “no wrist”).
Maximum reach distance: 2.55~3.5m.
Protection Class: The cast Expert is rated IP 67 and can be steam-cleaned, making it ideal for harsh production environments.
Power supply: DC9-36V wide redundant dual power supply, DC1500V power isolation, reverse protection.
Communication rate: Supports a variety of communication rates, including 9.6kBit/s, 19.2 kBit/s, 45.45kBit/s, 93.75kBit/s, 187.5kBit/s, 500kBit/s, 1.5MBit/s, 6MBit/s, and 12MBit/s.
Size: Specific size information is not explicitly mentioned in the search results, but modules are usually designed to be compact to accommodate different installation environments.
Weight: There is talk of 0.1KG, but please note that this is only a rough estimate and the actual weight may vary by production lot and configuration.
specification
High-resolution feedback: 24-bit high-resolution feedback provides precise motor position and motion control.
High performance current loop bandwidth: 3-5 kHz, ensuring fast response and precise control.
Intelligent feedback device: with electronic motor nameplate, no need to set drive parameters and servo loop adjustment, support plug and play debugging.
Communication interface: Support EtherCAT, CANopen, Modbus and other communication protocols, easy to communicate with other devices and control systems.
Size and weight
Dimensions: 2.0 “x 7.0” x 5.0 “(or 5.1 cm x 17.8 cm x 12.7 cm).
Weight: Depending on the source, the weight may vary, there are claims of 0.9kg and 2KG.
argument
Voltage: The voltage range may include +10% to -15%, but the specific operating voltage may vary by model, and it is said to be 24V.
Current: The current range may vary depending on the application, and is said to be 100-400A.
Control period: The high-speed gLink-II interface has a control period of up to 50 microseconds, and the universal gLink-II and EtherCAT interfaces have a control period between 250 microseconds and 4 milliseconds.
CPU speed: A high speed CPU executes each basic instruction in just 0.9 microseconds.
specification
Network interface: Provides high-speed gLink-II, universal gLink-II and EtherCAT three network interfaces.
Multi-axis control: Supports high-performance closed-loop control of 8 axes (high-speed gLink-II) and motion control of up to 256 axes (universal gLink-II/EtherCAT).
Memory: Built-in large capacity program storage, up to 10K steps.
Size and weight
Weight: Some say 2KG, but others say 1KG