Showing 3109–3120 of 3716 results
¥ 6,035.00
Parameters and Specifications :
Input Voltage : 70-265 VAC, 90-300 VDC1
Control Power : 5A phase secondary2
Operating Temperature : -25°C to +55°C3 , also stated as -10°C to 70°C (-40°C to +85°C optional)4
Storage Temperature : -40°C to +70°C4
Humidity : ≤90% (non-condensing)4
Dimensions : 120mm x 90mm x 50mm4 , also stated as 100mm x 150mm x 70mm3
Weight : Not explicitly stated.
Series :
GE Multilin SR 469 Motor Management Relay Series2 5
¥ 4,652.00
Parameters and Specifications :
Type : Motor Management Relay
Manufacturer : General Electric (GE)
Series : 369 Series
Voltage Rating : 220V (or as specified in specifications)
Current Rating : 5A (or as specified in specifications)
Control Power : 110-250V DC, 100-240V AC
Frequency : 50/60 Hz
Protection Functions : Overcurrent, Overload, Undervoltage, etc.
Dimensions and Weight :
Approximate Dimensions (Based on similar models): Height 11.5 inches x Width 5.5 inches x Length 8.5 inches1 or Height 12 inch x Width 5 inch x Length 8 inch2
Weight : Approximate 8 pounds1 or 4.5 kg2
¥ 6,235.00
Parameters and Specifications :
Model : D20-EME
Brand : GE (General Electric)
Type : (Likely a component or device from GE’s industrial or power generation products)
Electrical Rating : Specific ratings would depend on the intended application and configuration.
Environmental Ratings : Likely designed for industrial or power plant environments.
Dimensions and Weight :
Exact Dimensions : Not readily available without a specific datasheet or product manual.
Weight : Similarly, the weight would depend on the specific configuration and materials.
¥ 4,562.00
Parameters and Specifications:
Type: Electronic power board
Application: Used in excitation systems of electric generators
Power Output: Provides the required power voltage and current for the excitation system
Voltage Regulation: Adjusts the output voltage of the electric generator based on need
Overcurrent Protection: Protects the excitation system from damage due to current overload
Communication Interface: May include interfaces for communication and data transmission with generator control or monitoring systems
Operating Temperature: (-22°F to +150°F) or (0-55℃)
Humidity: 95%, non-condensing
Dimensions and Weight:
Exact Dimensions and Weight: Not explicitly provided in the search results.
¥ 4,265.00
Parameters:
Model: GE 8851-LC-MT
Interface Type: LC
Transmission Rate: 10/100/1000Mbps
Operating Wavelength: 1310nm
Transmit Power: -9.5dBm~0dBm
Receive Sensitivity: -20dBm
Maximum Transmission Distance: 10km
Operating Temperature: -40℃~85℃
Specifications:
Size: 57mm x 14.5mm x 13.4mm (another source mentions 265354mm, but this may refer to a different aspect or be a typo)
Material: Aluminum Alloy Shell
Power: 3.3V
Compatibility: IEEE802.3z Standard
¥ 4,026.00
Parameters:
Control Principle: Through stored program periodic operation, single-phase.
Range: -2147483648 to +2147483647.
Temperature Control: With multiple auxiliary functions available.
Specifications:
Brand: GE (General Electric).
Model: DS200NATOG3A.
Size: DS200NATOG3Amm.
Accuracy: Not Specified.
Purpose: Temperature control and monitoring.
¥ 5,264.00
Parameters:
Control Power: 70-265 VAC, 90-300 VDC
Electrical Interface: Support Profibus DP A and B half duplex working modes; standard Profibus DB9 interface; rate: 0 ~ 6m (optional ~ 12m) adaptive
Optical Fiber Interface: Optical fiber wavelength: multimode: 850nm, 1310 nm; single mode: 1310 nm, 1550 nm; transmission distance: multimode 2km; single mode: 10 ~ 60km
Operating Temperature: -25℃ ~ +55℃
Storage Temperature: -40℃ ~ +70℃
Specifications:
Series: GE Multilin 469 Motor management relay series
Size: 100mm x 150mm x 70mm
Weight: Not Specified
Protection Class: IP20
¥ 3,652.00
Parameters:
Processor: Intel Celeron-M microprocessor
Processing Speed: 1 GHz
User Memory: 20 MB (RAM)
Flash Memory: 20 MB
I/O Operations per Second: Up to 32K
Max. Program Blocks: 512
Max. Program Block Size: 128 KB each
Specifications:
Series: GE Fanuc PACSystems RX3i Series
Operating Voltage and Frequency: Not Specified
Programmable Languages: C, Ladder Logic, Structured Text, or Function Block Diagram
Communication Interfaces: Ethernet, RS-232, RS-485
¥ 3,201.00
Parameters and specifications:
Features: The VMIVME-3122 is a high-resolution, 16-bit, 64-channel analog scanning and digital input board for VME bus system applications.
Analog inputs: Support 16, 32 or 64 differential or single-ended analog inputs.
A/D conversion: with 16-bit A/D conversion function.
Scan rate: Optional scan rate from 381 Hz to 100 kHz (high performance option) or optional scan rate from 381 Hz to 50 kHz (standard performance option).
Gain: Programmable gain of x1 or x10.
A/D converter range: ± 2.5V, ± 5V, ± 10V, 0 to + 5V, 0 to + 10V.
Data buffer: 16 to 1,024 word dual-port data buffer.
Operating mode: Continuous and burst operating mode, free running or external/internal triggering.
¥ 6,214.00
Parameters and Specifications :
Model : GE SR750-P5-G5-S5-HI-A20-R
Power Rating : Likely 750kVA or kW, depending on the context
Input Voltage : Specified by the manufacturer, typically 400V, 415V, or 480V AC
Output Voltage : Specified by the manufacturer, typically the same as the input voltage
Frequency : 50/60Hz (configurable or auto-sensing)
Topology : Online double conversion (ODC) or similar
Efficiency : Specified by the manufacturer
Dimensions and Weight :
Exact dimensions and weight are typically provided in the product manual or specification sheet. However, UPS systems are designed for rack mounting or floor standing installation.
¥ 4,120.00
Parameters and Specifications:
Technical Specifications:
Analog Output: 4 to 20 mA
Control Authority: ‘High’
DC Voltage: 90-300 VDC
AC Voltage: 70-265 VAC, 48-62 Hz
Display: Ethernet Enhanced Display (10Base-T)
Environment: For harsh environments (when ‘H’ is added to the part number)
Dimensions and Weight:
Dimensions and Weight are not explicitly mentioned in the search results.
¥ 5,260.00
Parameters and Specifications :
Rated Voltage : Typically 72.5 kV or 145 kV, depending on the equipment configuration and application needs1 .
Rated Current : The rated current will vary based on the equipment model and application scenario. Typically, GIS equipment has a rated current range from several hundred amperes to several thousand amperes1 .
Switch Type : GIS equipment typically includes different types of switching devices such as circuit breakers, disconnectors, grounding switches, etc.1 .