GE DS200LDCCH1ANA
¥12,999.00Product Parameters
| Parameter Category | Specification Details |
|---|---|
| Brand & Model | GE DS200LDCCH1ANA |
| Product Series | Mark V Control System Spare Part |
| Operating Voltage | 24V DC ±10% |
| Input/Output Channels | Configurable digital I/O channels (varies by system setup) |
| Communication Protocol | Supports GE Proprietary Protocol, Modbus RTU |
| Operating Temperature Range | -40°C to 70°C |
| Storage Temperature Range | -55°C to 85°C |
| Humidity Tolerance | 5% – 95% (non-condensing) |
| Dimensions (L×W×H) | Standard industrial form factor (150mm×100mm×50mm, subject to verification) |
| Weight | Approx. 0.8kg |
| Certification | UL, CE, ISO 9001 Certified |
GE DS200ADMAH1A
¥2,599.00Product Parameters
| Parameter Name | Specific Specifications |
|---|---|
| Brand & Model | GE DS200ADMAH1A |
| Product Type | Industrial-grade high-reliability digital input module |
| Input Channels | 16 independent digital input channels |
| Input Signal Type | Dry contact input, compatible with NPN/PNP sensors (configurable) |
| Input Voltage Range | 24VDC (±10%), wide-voltage adaptation: 19.2VDC ~ 30VDC |
| Input Current | Typical value: 5mA @ 24VDC; Maximum: 8mA |
| Response Time | Standard mode: ≤1ms; High-speed mode: ≤0.2ms (configurable) |
| Input Impedance | ≥1kΩ |
| Operating Voltage | 24VDC (±10%), supports redundant power supply |
| Power Consumption | Typical: 6.5W; Maximum: 8.2W (full load) |
| Operating Temperature | -40℃ ~ +70℃ |
| Storage Temperature | -55℃ ~ +85℃ |
| Relative Humidity | 5% ~ 95% (non-condensing, altitude ≤ 2000m) |
| Protection Level | IP20 (module body); Optional front panel IP40 protection |
| Isolation Method | Channel-to-channel electrical isolation (250VAC/1min); Module-to-backplane optical isolation |
| Compatible Systems | GE Mark VIe, Mark VI, Speedtronic series control systems |
| Communication Protocol | Supports GE Proprietary Protocol, Modbus TCP, Ethernet/IP |
| Dimensions (L×W×H) | 140mm × 85mm × 68mm |
| Weight | Approximately 420g |
| Certification Standards | UL, CSA, CE, IEC 61131-2, IEC 61010-1, RoHS |
| Mean Time Between Failures (MTBF) | >180,000 hours |
| Diagnostic Functions | Channel open-circuit detection, power failure alarm, overvoltage protection, signal drift monitoring |
GE DS200CDBAG1ABA
Product Parameters
| Parameter Name | Specific Specifications |
|---|---|
| Brand & Model | GE DS200CDBAG1ABA |
| Product Type | Data Communication & Processing Module (for GE Mark VIe Control System) |
| Supported Communication Protocols | GE Speedtronic, Ethernet/IP, MODBUS TCP, PROFINET IO |
| Communication Interfaces | 2 x 10/100/1000M adaptive Ethernet ports (RJ45), 1 x dedicated GE controller bus interface |
| Data Transmission Rate | Up to 1000 Mbps (Gigabit Ethernet), 100 Mbps (controller bus) |
| Communication Distance | 100m for Ethernet (Cat5e/Cat6 cable); 50m for controller bus |
| Operating Voltage Range | 20.4V DC – 28.8V DC |
| Operating Temperature Range | -40°C – +70°C |
| Storage Temperature Range | -40°C – +85°C |
| Protection Class | IP20 (module body) |
| Mounting Method | 35mm DIN rail mounting |
| Compatible Control Systems | GE Mark VIe, Mark VI, and select Mark V control systems |
| Dimensions (L×W×H) | 135mm × 155mm × 65mm |
| Weight | Approximately 0.58kg |
| Protection Functions | ESD protection (±25kV contact discharge), overvoltage protection, short-circuit protection, network overload protection |
| Status Indicators | Power indicator, Ethernet link indicator, data transmit/receive indicator, controller bus status indicator, fault alarm indicator |
| Diagnostic Functions | Built-in network fault self-diagnosis, protocol error logging, connection status monitoring |
GE DS200ADGIH1AAA
¥12,999.00Product Parameters
| Parameter Name | Specific Specifications |
|---|---|
| Brand & Model | GE DS200ADGIH1AAA |
| Product Type | Digital I/O Hybrid Module (for GE Mark VIe Control System) |
| Input Channel Count | 16 digital input channels |
| Output Channel Count | 16 digital output channels |
| Input Signal Type | 24V DC dry contact/wet contact, sinking input (NPN) |
| Output Signal Type | 24V DC sourcing output (PNP), configurable for high-side switching |
| Single-Channel Output Current | Maximum 2A per output channel |
| Total Output Current | ≤15A (sum of all output channels) |
| Input Response Time | ≤1ms |
| Output Response Time | ≤2ms |
| Operating Voltage Range | 20.4V DC – 28.8V DC |
| Operating Temperature Range | -40°C – +70°C |
| Storage Temperature Range | -40°C – +85°C |
| Protection Class | IP20 (module body) |
| Mounting Method | 35mm DIN rail mounting |
| Compatible Control Systems | GE Mark VIe, Mark VI, and selected Series 90-70 PLCs |
| Dimensions (L×W×H) | 140mm × 155mm × 68mm |
| Weight | Approximately 0.6kg |
| Protection Functions | Overcurrent protection, short-circuit protection, reverse polarity protection, ESD protection (±25kV contact discharge) |
| Status Indicators | Power indicator, input channel activity indicators, output channel activity indicators, fault alarm indicator |
| Diagnostic Functions | Built-in channel fault self-diagnosis, overcurrent/short-circuit alarm logging |
GE DS200ACNAG1ADD
¥12,999.00GE IC693ALG392B
¥25,899.00Product Parameters
| Parameter Name | Specific Specifications |
|---|---|
| Brand & Model | GE IC693ALG392B |
| Product Type | Analog Input Module (for GE Series 90-30 PLC) |
| Input Channels | 8 differential input channels |
| Supported Signal Types | 4-20mA DC, 0-20mA DC, 0-10V DC, ±10V DC; compatible with thermocouples (J/K/T/E/R/S/B) and RTDs (PT100) |
| Input Accuracy | ±0.1% Full Scale (FS) for current/voltage signals; ±0.2% FS for thermocouple/RTD signals |
| Signal Conversion Time | ≤10ms per channel |
| Sampling Rate | 50Hz per channel |
| Operating Voltage Range | 120/240V AC (power supply module dependent) |
| Operating Temperature Range | 0°C ~ 60°C |
| Storage Temperature Range | -40°C ~ 85°C |
| Protection Class | IP20 (module body) |
| Mounting Method | DIN rail mounting (35mm standard rail) |
| Compatible PLC Series | GE Series 90-30 PLC |
| Communication Interface | GE Genius Bus protocol |
| Dimensions (L×W×H) | 127mm × 89mm × 152mm |
| Weight | Approximately 0.5kg |
| Protection Functions | Overvoltage protection, reverse polarity protection, electrostatic discharge (ESD) protection (±15kV contact discharge) |
| Status Indicators | Power indicator, channel activity indicators, system fault indicator |
GE IC695PSD140
¥25,999.00Key Technical Specifications
| Parameter Category | Detailed Specifications |
|---|---|
| Module Type | Redundant AC-to-DC power supply module for GE RX3i PLC systems |
| Input Voltage Range | 85–264V AC (50/60Hz, universal input for global compatibility) |
| Output Voltage & Current | 24V DC (±0.5V regulation); 14A total output (7A per redundant PSU) |
| Redundancy Design | 1+1 redundant PSUs; Automatic switchover (<1ms) if primary PSU fails |
| Protection Features | Overload protection (150% of rated current), short-circuit protection, over-temperature shutdown |
| Efficiency | ≥85% (at full load, 230V AC input) |
| Operating Temperature | -20°C ~ +60°C (no derating required within range) |
| Protection Rating | IP20 (panel-mounted in standard 19-inch control cabinets) |
| Form Factor | DIN-rail mountable; Dimensions: 140mm (W) × 100mm (H) × 60mm (D) |
| Compatibility | GE RX3i PLC systems (IC695CPU310/330), GE RX3i I/O modules (e.g., IC695IOL101), third-party 24V DC devices |
| Diagnostic Features | LED indicators for PSU status (normal/fault), output voltage monitoring, fault logging |
GE IS200EPCTG1A
Product Parameters: Technical Specifications of GE IS200EPCTG1A
| Parameter Category | Specifications |
|---|---|
| Module Type | 4-channel AI + 2-channel AO analog I/O module |
| AI Signal Compatibility | 4–20mA DC (current), 0–10V DC (voltage); configurable per channel |
| AO Signal Output | 4–20mA DC (sink/source), 0–10V DC; maximum load: 500Ω (current), 1kΩ (voltage) |
| Resolution | 16-bit (AI/AO) |
| Accuracy | ±0.1% of full scale (FS) at 25°C; ±0.2% FS over operating temperature range |
| Operating Temperature | -40°C to +70°C (-40°F to +158°F) |
| Power Supply | 24V DC (redundant input); typical power consumption: 3.5W |
| Isolation | Channel-to-channel: 500V AC (galvanic); Module-to-ground: 1kV AC |
| Certifications | IEC 61000-6-2 (EMC), UL 508 (industrial control), CSA C22.2 No. 142 |
| Compatibility | GE Mark VIe DCS; requires IS200EPDHG1B baseplate for mounting |
| Response Time | <10ms (AI signal conversion); <5ms (AO command execution) |
GE 516TX 336A4940DNP516TX
¥9,999.00Technical Parameters
- Device Type: Multifunctional protection relay for medium-voltage (3–35kV) power systems
- Core Protection Functions:
- Short-Circuit Protection: Three-stage overcurrent protection (instantaneous, time-delayed instantaneous, overcurrent) with adjustable setting range 0.5–20×CT rated current and operating time 0.01–10s
- Overload Protection: Inverse-time or definite-time selectable, setting current 1.0–1.5×rated current, operating time 1–120s
- Voltage Protection: Overvoltage protection (105–120% rated voltage), undervoltage protection (80–95% rated voltage), operating time 0.1–10s
- Additional Protection: Phase-failure protection, earth fault protection, CT open-circuit detection, overtemperature protection (optional)
- Measurement Parameters:
- Current Measurement: Configurable CT ratio 1–2000:5A, accuracy ±0.2%FS
- Voltage Measurement: Configurable VT ratio 100–10000:100V, accuracy ±0.2%FS
- Power Measurement: Active power, reactive power, apparent power, accuracy ±0.5%FS
- Frequency Measurement: 45–65Hz, accuracy ±0.01Hz
- Communication & Control:
- Communication Interfaces: RS-485 (supports Modbus RTU), Ethernet (supports Modbus TCP, DNP3.0 protocols)
- Control Outputs: 4 groups of programmable relay outputs (NO/NC selectable), rated load AC 250V/5A, DC 30V/3A
- Signal Inputs: 8 digital inputs (for external interlock signal access)
- Power Supply & Power Consumption:
- Supply Voltage: AC/DC 110–240V (wide voltage adaptation), power consumption ≤15W
- Environmental & Mechanical Specifications:
- Operating Temperature: -40℃~+70℃ (operation), -40℃~+85℃ (storage)
- Protection Class: IP54 (suitable for outdoor distribution cabinets or harsh indoor environments)
- Mounting Type: Panel mounting/rail mounting optional
- Dimensions: 144mm (width) × 144mm (height) × 120mm (depth)
- Weight: Approximately 1.8kg
- Certifications & Standards:
- Complies with IEC 61850, IEC 60255, UL 508, CE and other international standards
- Protection Setting Storage: Non-volatile memory, data retention ≥10 years after power-off
GE DS200DCFBG2BNC MRP420024
¥9,999.00Product Parameters
- Component Type: Industrial DC-DC power supply module, dedicated to powering GE Speedtronic Mark VI/VII turbine control system electronics.
- Input Specifications: DC input voltage range 18–32 V DC (nominal 24 V DC), compatible with GE’s redundant power supply systems; input current ≤ 10 A (full load).
- Output Specifications: Dual isolated output channels; Channel 1: 5 V DC, 4 A (continuous), 6 A (peak, ≤ 3 seconds); Channel 2: 15 V DC, 2 A (continuous), 3 A (peak, ≤ 3 seconds); output voltage regulation ±0.1% (line regulation), ±0.2% (load regulation).
- Isolation Performance: Input-output isolation voltage 2500 V AC (1 minute); inter-channel isolation voltage 1500 V AC (1 minute); insulation resistance ≥ 100 MΩ at 500 V DC, ensuring protection against voltage transients and cross-channel interference.
- Ripple and Noise: ≤ 50 mVpp (Channel 1, 5 V DC); ≤ 100 mVpp (Channel 2, 15 V DC), minimizing interference with sensitive control electronics (e.g., analog signal converters).
- Protection Functions: Overload protection (auto-recovery after fault clearance), short-circuit protection (current limiting), over-voltage protection (clamping at 110% of nominal output), over-temperature protection (auto-shutdown at ≥ 85°C), and reverse-polarity protection (input terminal).
- Operating Environment: Temperature range -20°C to +70°C (operating); -40°C to +85°C (storage); relative humidity 5%–95% (non-condensing); vibration resistance up to 5 g (10–500 Hz); shock resistance up to 20 g (half-sine pulse, 11 ms duration).
- Mechanical Specifications: Metal housing with IP20 protection rating; DIN rail or panel mounting; dimensions (W×D×H) 120 mm × 180 mm × 60 mm; weight ≈ 0.8 kg.
- Compatibility: Fully compatible with GE Speedtronic Mark VI, Mark VIe, and Mark VII turbine control systems; compatible with GE DS200 series I/O modules, IS200 series excitation controllers, and Turbine Control Panels (TCPs).
- Diagnostic Features: LED indicators for power status (green: normal; red: fault), output current monitoring, and over-temperature alerts; diagnostic data accessible via GE’s ToolboxST software for remote troubleshooting.
- Compliance Standards: IEC 61000-6-2 (EMC immunity), IEC 61000-6-4 (EMC emissions), UL 508 (industrial safety), CE marking, and GE’s internal turbine control system certification (Mark VI/VII compliant).
GE IS220PPRFH1A
¥23,999.00Technical Specifications
- Device Type: Industrial PID control module for GE Mark VIe control systems
- Control Function: Proportional-Integral-Derivative (PID) control; supports cascade control and feedforward control
- Input Channels: 4 analog input channels (4–20 mA DC, 16-bit resolution) for sensor feedback
- Output Channels: 2 analog output channels (4–20 mA DC, 16-bit resolution) for actuator control
- Processing Speed: PID loop update rate ≤ 10 ms (ensures real-time response to process changes)
- Control Accuracy: ±0.1% of full scale (FS) for both input sampling and output signals
- Operating Environment: Temperature range 0°C to +60°C; humidity 5%–95% (non-condensing)
- Power Supply: 24 V DC (redundant input design, voltage range 19.2 V–28.8 V); power consumption ≤ 6 W
- Dimensions: 90 mm × 120 mm × 35 mm (L × W × H); compatible with GE Mark VIe standard racks
- Protection Rating: IP20 (suitable for cabinet-mounted installation in control rooms)
- Mounting Method: Slot-mounted in GE Mark VIe control racks (no additional brackets required)
- Additional Features: Built-in loop tuning tools, fault diagnostics (via GE CIMPLICITY software), over-range/under-range protection, and Modbus TCP communication for remote monitoring
←1…3839404142…
434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309
310→