argument
Input voltage: Usually 24V DC, but may vary according to the application scenario
Working voltage: 24V
Rated voltage: 24V
Power supply voltage: 220V
Rated current: 5A
System memory: 8MB
Memory expansion capacity: 128MB
Display color: 99.9% (may refer to the color depth or number of colors on the display)
Working temperature: The working environment temperature is -40 to 100℃
Communication interface: Support HDMI interface
Processor speed: 1 GHz
User memory: 20 MB (random access memory or RAM)
Flash memory: 20 MB
I/O operations: Capable of up to 32K I/O operations per second
Number of blocks: A maximum of 512 blocks are supported, and the maximum size of each block is 128 KB
specification
Series: GE Fanuc PACSystems RX3i series
Programming environment: Support a variety of programming languages, such as C language, ladder logic (ladder diagram), structured text, functional block diagram, etc
Communication interface: including Ethernet interface, serial interface (such as RS-232, RS-485), support SNP, serial I/O and Modbus slave and master serial protocols
Receives engineering unit output data (BIU) from the bus interface.
Other parameters:
Parameters such as operating temperature, storage temperature, and ambient humidity may vary depending on the application scenario, but are generally applicable to industrial environments.
Size and weight
Dimensions: 149.2 x 44.45 x 115.6 mm (5.875 x 1.75 x 4.55 inches).
Weight: Not given directly, but based on size and material, it is likely to be around a few hundred grams to a kilogram.
series
Part of GE Fanuc’s (now Emerson) family of Genius field control stations.
Input voltage range: The input voltage range varies depending on the source. One says 18 to 30 VDC, another says 12 to 48VDC, and still another says DC 9 to 36V (probably referring to a wide power input range).
Backplane current: 170 mA per channel
specification
Number of channels: 8 single-ended analog voltage outputs
Anti-noise isolation channel: supported
Field configuration: Flexible Settings
Data types: Use both word and bit data types
Calibration: Can be recalibrated on site or reset to factory calibration
Size and weight
Size: Sizes vary depending on the source. One said it was 149.2 x 44.45 x 115.6 mm (5.875 x 1.75 x 4.55 inches) and another said it was 170mm x 105mm x 32mm
Weight: About 120g
argument
Type: Bus interface module or circuit breaker
Rated voltage: 600V AC (when used as circuit breaker)
Rated current: 50A (as a circuit breaker)
Number of poles: 2 (when used as a circuit breaker), but there is also talk of 3 poles
Interrupt rating: varies according to voltage, e.g. 10kAIC at 240V AC, 5kAIC at 480V AC, 3kAIC at 600V AC (when used as a circuit breaker)
Frequency: 50/60 Hz
specification
Manufacturer: General Electric (GE)
Model: 8502-BI-DP