Showing 973–984 of 6997 results

GE DS3800HMAC1F1E

¥999.00

The General Electric DS3800HMAC1F1E is a high-performance analog input/output module purpose-built for the Mark IV and Mark V Speedtronic turbine control systems. This board functions as the primary analog signal conditioning interface, converting field signals from thermocouples, RTDs, pressure transmitters, and LVDTs into digital data for the turbine’s main protection and sequencing logic. As a core component of GE’s heavy-duty gas and steam turbine ecosystems, the General Electric DS3800HMAC1F1E is designed for 24/7 operation in environments where a single channel failure can trigger a turbine trip, making its reliability paramount.

DS3800HMAC GE

¥999.00

GE DS3800HMAC is a high-density analog input module for GE Speedtronic Mark IV/V gas turbine control systems. The “HMAC” suffix designates a configuration combining high-precision analog measurement (HMA) with advanced calibration and compensation (C) features—specifically, per-channel zero/span digital trimming and real-time cold-junction compensation for external thermocouple transmitters. Unlike standard modules, GE DS3800HMAC provides ±0.05% accuracy with factory-stored calibration coefficients per channel, plus user-configurable offset and gain adjustments for field sensor matching. The module supports true hot-swap, operates from -40°C to +85°C, and accepts ±10V, 0–10V, and 4–20mA inputs. The “C” suffix adds a dedicated calibration EEPROM per channel, allowing GE DS3800HMAC to compensate for sensor-specific non-linearity and cable losses—critical for applications where sensor interchangeability or long cable runs introduce measurement errors.

DS3800HMAA GE

¥999.00

GE DS3800HMAA is a high-density analog input module for GE Speedtronic Mark IV/V gas turbine control systems. The “HMAA” suffix designates a configuration optimized for high-level analog inputs with enhanced accuracy, featuring 16-bit resolution, 1kHz sampling, and ±0.05% calibrated accuracy—superior to standard HLOC/HLSC variants. Unlike general-purpose PLC I/O, GE DS3800HMAA is specifically designed for precision measurement of critical turbine parameters such as fuel valve position, exhaust temperature gradients, and high-accuracy pressure transducers. The module supports true hot-swap, operates from -40°C to +85°C, and includes a dedicated precision voltage reference and autocalibration circuitry that compensates for temperature drift. GE DS3800HMAA accepts ±10V, 0–10V, 0–5V, and 4–20mA inputs, making it versatile for both dynamic and steady-state precision applications.

GE DS3800HLXB1B1C

¥999.00

GE DS3800HLXB1B1C is a high-density local I/O module for GE Speedtronic Mark IV/V gas turbine control systems. The suffix “XB” provides a deep 16,384-sample FIFO buffer per channel with simultaneous sampling (<1µs phase skew). The “1B” adds dual-redundant thermocouple support (Types J/K/T/S) with cross-channel voting logic. The “1C” provides extended analog ranges (±10V, 0–20mA, 4–20mA) with a 100Hz anti-aliasing Bessel filter. This combination makes GE DS3800HLXB1B1C the most versatile long-duration capture module in the DS3800 series, capable of simultaneously monitoring vibration sensors (±10V), pressure transmitters (4–20mA), and redundant thermocouples—all with extended buffering for events up to 16 seconds at 1kHz or 27 minutes at 10Hz. The module supports true hot-swap and operates from -40°C to +85°C.

DS3800HLXB GE

¥999.00

GE DS3800HLXB is a high-density local I/O module for GE Speedtronic Mark IV/V gas turbine control systems. The “HLXB” suffix designates a configuration with eXpanded Buffering capability—specifically, a deep 16,384-sample FIFO per channel (16x larger than standard SC variants) combined with enhanced trigger logic and hardware timestamping at 1µs resolution. Unlike general-purpose PLC I/O, GE DS3800HLXB is designed for extended-duration transient capture, such as full startup sequences, load rejection events, or multi-minute surge oscillations. The module supports true hot-swap, operates from -40°C to +85°C, and includes simultaneous sampling (shared XA architecture) with ±10V, 0–10V, and 4–20mA input ranges. GE DS3800HLXB is the go-to choice when standard 1024-sample buffers are insufficient for capturing long-duration dynamic events.

DS3800HLXA1C1E GE

¥999.00

GE DS3800HLXA1C1E is a high-density local I/O module for GE Speedtronic Mark IV/V gas turbine control systems. The suffix “XA” provides simultaneous sampling across all 16 channels with <1µs phase skew. The “1C” adds extended analog ranges (±10V, 0–20mA, 4–20mA) with a 100Hz anti-aliasing Bessel filter. The “1E” designates an enhanced event-triggered logging firmware with timestamping and pre-programmed event profiles. This combination makes GE DS3800HLXA1C1E the most advanced dynamic measurement module in the DS3800 series, purpose-built for phase-critical, noise-immune, event-driven data acquisition. The module supports true hot-swap, operates from -40°C to +85°C, and includes a 1024-sample FIFO buffer per channel with hardware timestamping at 1µs resolution.

GE DS3800HLXA

¥999.00

GE DS3800HLXA is a high-density local I/O module for GE Speedtronic Mark IV/V gas turbine control systems. The “HLXA” suffix designates a specialized configuration with eXpanded Analog functionality—specifically, 14-bit simultaneous sampling across all 16 channels, a feature not present in HLOC/HLSC/HLSD variants. Unlike general-purpose PLC I/O, GE DS3800HLXA is designed for applications requiring phase-coherent measurement of multiple sensors (e.g., vibration phase analysis, dynamic pressure arrays, or multi-point temperature gradients). The module supports true hot-swap, operates from -40°C to +85°C, and includes simultaneous sample-and-hold circuitry that ensures all channels are captured at the exact same instant, eliminating time-skew errors common in multiplexed systems. GE DS3800HLXA accepts ±10V, 0–10V, and 4–20mA inputs, making it versatile for both dynamic and steady-state monitoring.

GE DS3800HLSD1A1A

¥999.00

GE DS3800HLSD1A1A is a high-density local I/O module for GE Speedtronic Mark IV/V gas turbine control systems. The suffix “1A1A” designates a specific factory configuration: the first “1A” provides standard analog input ranges (0–10V / 4–20mA) with enhanced 50/60Hz EMC filtering, while the second “1A” indicates the logging firmware variant optimized for single-channel (non-redundant) data acquisition with standard compression. Combined with the “SD” serial data logging feature, GE DS3800HLSD1A1A offers 2MB onboard flash storage for extended trend recording. Unlike general-purpose PLC I/O, GE DS3800HLSD1A1A functions as a signal bridge between field sensors and the main turbine controller, while simultaneously logging historical data to non-volatile memory. The module supports true hot-swap, operates from -40°C to +85°C, and includes enhanced EMI filtering for electrically noisy environments. The 1A1A combination makes GE DS3800HLSD1A1A the most cost-effective logging-enabled variant when redundancy is not required.

GE DS3800HLSD

¥999.00

GE DS3800HLSD is a high-density local I/O module for GE Speedtronic Mark IV/V gas turbine control systems. The “HLSD” suffix designates a configuration optimized for high-level analog signal conditioning with Serial Data logging capability—distinct from the “SC” variant by including non-volatile flash storage for extended trend recording. Unlike general-purpose PLC I/O, GE DS3800HLSD functions as a signal bridge between field sensors (high-level voltage transducers, current loops, and vibration probes) and the main turbine controller, while simultaneously logging historical data to onboard memory. The module supports true hot-swap and operates from -40°C to +85°C. The “SD” feature adds 2MB of onboard flash memory, allowing GE DS3800HLSD to store up to 72 hours of trend data at 1Hz sampling—even if the main controller or Genius bus is offline.

GE DS3800HLSC1C1B

¥999.00

GE DS3800HLSC1C1B is a high-density local I/O communication and interface module manufactured by GE for the Speedtronic Mark IV and Mark V gas turbine control systems. The suffix breakdown indicates a specialized factory configuration: “1C” denotes extended analog input range (±10V, 0–20mA, and 4–20mA with enhanced 100Hz low-pass anti-aliasing filtering), while “1B” signifies a pre-installed firmware variant optimized for dual-redundant thermocouple acquisition combined with the “SC” serial co-processor for high-speed data buffering. Unlike a general-purpose PLC CPU, GE DS3800HLSC1C1B functions as a critical signal bridge between field sensors (thermocouples, high-level voltage transducers, current loops, vibration probes, and LVDT position sensors) and the main turbine controller rack. The module supports true hot-swap capability and incorporates multi-layer galvanic isolation circuitry. Engineered to withstand extreme ambient temperatures up to 85°C near the turbine skid, GE DS3800HLSC1C1B also features onboard signal preconditioning logic that outputs linearized engineering-unit values directly, significantly offloading the computational burden from the main processor. The “SC” serial co-processor adds a dedicated 16-bit microcontroller with a 1024-sample FIFO buffer per channel, while the “1C” anti-aliasing filter ensures high-frequency noise does not corrupt measurements—making GE DS3800HLSC1C1B the most versatile and feature-rich variant in the DS3800 series.

GE DS3800HLSC

¥999.00

GE DS3800HLSC is a high-density local I/O communication and interface module manufactured by GE for the Speedtronic Mark IV and Mark V gas turbine control systems. The “HLSC” suffix designates a configuration optimized for high-level analog signal conditioning with serial communication co-processing capability. Unlike a general-purpose PLC CPU, GE DS3800HLSC functions as a critical signal bridge between field sensors (thermocouples, pressure transmitters, vibration probes, and high-level voltage sensors) and the main turbine controller rack. The module supports true hot-swap capability and incorporates multi-layer galvanic isolation circuitry. Engineered to withstand extreme ambient temperatures up to 85°C near the turbine skid, GE DS3800HLSC also features onboard signal preconditioning logic that outputs linearized engineering-unit values directly, significantly offloading the computational burden from the main processor. The “SC” suffix further includes a dedicated serial co-processor for buffered data streaming, enabling GE DS3800HLSC to handle high-frequency transient signals (e.g., surge monitoring) without interrupting the main Genius bus traffic.

DS3800HLOC1A1B GE

¥999.00

GE DS3800HLOC1A1B is a high-density local I/O communication and interface module manufactured by GE for the Speedtronic Mark IV and Mark V gas turbine control systems. The suffix breakdown indicates a specific factory configuration: “1A” denotes standard analog input range (0–10V / 4–20mA) with enhanced EMC filtering, while “1B” signifies a pre-installed firmware variant optimized for dual-redundant thermocouple acquisition. Unlike a general-purpose PLC CPU, GE DS3800HLOC1A1B functions as a critical signal bridge between field sensors (thermocouples, pressure transmitters, vibration probes) and the main turbine controller rack. The module supports true hot-swap capability and incorporates multi-layer galvanic isolation circuitry. Engineered to withstand extreme ambient temperatures up to 85°C near the turbine skid, GE DS3800HLOC1A1B also features onboard signal preconditioning logic that outputs linearized engineering-unit values directly, significantly offloading the computational burden from the main processor.