Showing 5293–5304 of 7129 results
¥ 4,526.00
Parameters and Specifications :
Input Voltage : 24 V DC ± 20%1
Input Current : Max 5 mA / Max 0.5 A1
Number of Channels (Input/Output) : 16 each1 2
Resolution : 12-bit1 2
Output Type : Relay1
Output Range : 4 – 20 mA1 2
Operating Voltage : 220VAC3
Operating Temperature : -10…60℃3
Relative Humidity : <90%3
¥ 6,032.00
Parameters and specifications:
Input voltage: 90-264VAC.
Input current: 11.5A.
Output voltage: 24VDC.
Output current: 32A.
Power: 768W.
Operating temperature: -20℃~+70℃.
Output voltage accuracy: ±0.5% to ensure the stable operation of DCS system.
Efficiency: up to 90%, reducing energy consumption and heat production.
¥ 5,482.00
Parameters and specifications:
Power Supply and Protection:
Power supply: Dual power supply redundant input, DC(9-36)V, typical DC24V, power consumption less than 4W.
Relay alarm output: fiber link fault and power supply fault alarm output, contact capacity: DC48V/1A.
Vibration: 0.05g RMS (20 Hz to 2,000 Hz).
Shock: 5 g (half sine wave, duration 11 ms).
Mechanical characteristics:
Dimensions: Based on the search results, there are two possible sizes. One is 132mm×105mm×52mm, and the other is 224 mm× 168 mm× 64 mm.
Case: IP30 protection grade, corrugated aluminum reinforced case.
Mounting method: 35mm DIN rail mounting.
Net weight: Depending on the search results, there are two possible weights. One is 800g and the other is 2.3kg.
¥ 4,029.00
Parameters and Specifications :
Protection Functions : Includes motor overheat protection, motor start monitoring, rotor stall, phase-to-phase overcurrent, undercurrent, negative sequence protection, zero-sequence current, and circuit breaker failure protection1 .
Communication Interfaces : REF610 has two independent communication interfaces, RS-485 or fiber optic interface. Supports protocols such as MODBUS RTU/ASCII, IEC60870-5-103, DNP3.0, and SPA1 .
Fault Recording : REF610 has an integrated fault recorder module with four analog input channels and up to eight user-selectable switch channels for complete fault status recording1 .
Self-Diagnosis : The self-diagnosis function can determine the relay’s condition and issue warning signals before failure1 .
¥ 3,652.00
Parameters and specifications:
Power supply: 24V DC.
Number of inputs: Typically includes 8 digital inputs, 8 digital outputs, and 4 analog inputs, but the exact number may vary by model or application.
Input voltage range: 0-250V AC/DC.
Input type: Can be current or voltage.
Input resistance: 1MΩ.
Output type: relay or transistor.
Communication: Supports communication protocols such as Modbus, Profibus and Ethernet.
Temperature range: It can operate in the temperature range from -40°C to 70°C.
Certification: Certified for use in hazardous areas and in accordance with ATEX, IECEx and UL standards.
¥ 6,255.00
Parameters and specifications:
Function: Control industrial processes and machines.
Processor: 16-bit ARM processor with high performance and low power consumption.
Storage: 256 KB RAM for storing programs, data, and configurations; 16 MB Flash for storing programs and configurations.
Communication interface: Supports a variety of communication interfaces, such as Ethernet (10/100 Mbps), serial communication, Modbus RTU, etc.
I/O points: The number of words input 16, the number of words output 16.
Power supply: The operating voltage is 220V (but the input voltage is 24 V DC ± 20%).
¥ 4,150.00
ABB REX521GHHPSH06G is a high-performance component/device with specific technical specifications that include, but are not limited to:
Operating Voltage Range
Maximum Current Rating
Thermal Resistance
Frequency Response
Specifications :
The detailed specifications of the ABB REX521GHHPSH06G are tailored to meet specific industrial or automation needs. Some key specifications may include:
Input/Output Configurations
Protection Classes
Environmental Operating Range
Connectivity Options
¥ 5,410.00
Parameters and Specifications :
Model : UPC090AE01
Manufacturer : ABB
Type : PLC Module
Input/Output : 32 digital I/O, 8 analog I/O, 2 high-speed pulse output1
Communication Protocol : Supports Modbus RTU1
Voltage : Supports 24VDC and 230VAC2
Power Consumption : <50W1
Operating Temperature : -40°C to +70°C1
Humidity : 5% to 95% (non-condensing)1
Protection Level : IP67
¥ 6,205.00
Parameters and Specifications :
Control Modes : PID control, fuzzy control, adaptive control1 .
Input Signals : Analog (0-10V, 4-20mA), digital (ON/OFF)1 .
Output Signals : Analog (0-10V, 4-20mA), digital (ON/OFF)1 .
Control Accuracy : ±0.1%FS5 .
Communication Interfaces : RS485, Modbus, Profibus1 .
Operating Temperature : -10℃~+55℃1 .
Power Supply Voltage : AC220V/DC24V1 .
¥ 4,150.00
Parameters and specifications:
Working power supply: 220V/380V ±10% 50HZ.
Ambient temperature: -10℃~40℃ (instrument characteristics), 0 ~ +55℃ (climatic operating conditions).
Communication port: MODBUS TCP port, transmission speed: 10/100 Mbit/s (Ch1), 10 Mbit/s (Ch2).
Control principle: Other.
Size and weight:
Net depth/length: 185mm.
Product height: 127.5mm.
Product width: 59 mm.
Net weight: 0.621 kg.
¥ 5,262.00
Parameters and Specifications :
Number of Inputs and Outputs : 2 digital outputs.
Measurement Range : 0…600 bar; 0…8700 psi; 0…60 MPa.
System Connection : Threaded connection G 1/4 female.
Operating Voltage : 18…30 DC.
Current Consumption : < 35 mA.
Number of Outputs : 2.
Output Signal : Switching signal; IO-Link (configurable).
Electrical Design : PNP/NPN.
Short-Circuit Protection : Yes, pulse type.
Overload Protection : Yes.
Response Time : < 3 ms.
Ambient Temperature : -25…80 °C.
Storage Temperature : -40…100 °C.
Enclosure Protection Class : IP 65; IP 67.
¥ 4,521.00
Parameters and Specifications :
Operating Frequency : 60HZ
Output Modes : Automatic Calculation, Output PPM and %
Measurement Range : 1ug~100mg
Resolution : 0.1ug
Titration Speed : 2.1mg/min
Sensitivity : Not greater than 2% for 0.1ug~100g, converts to 0 above 1mg
Voltage : 24V
Maximum Output Current : 15A
Operating Temperature Range : -25~70℃
Current : 100~400A
Weight : 2KG