-Input Voltage: 24V DC
-Input Current: Maximum 400 mA
-Output Voltage: 24V DC
-Output Current: Maximum 1.6 A
-Operating Temperature: -20°C to +55°C
-Storage Temperature: -40°C to +85°C
Dimensions and Weight:
-Dimensions: 119.5 mm height, 12.5 mm width, 114.5 mm depth
-Weight: Approximately 160 g
-Input Voltage Range: Typically 12-48VDC
-Input Signal Types: Configurable for voltage or current input, such as 0(4)…20mA, 0(1)…5V, but cannot be mixed within the same I/O module
-Input Resistance: Voltage input > 10MΩ, current input 250Ω
-Output: Converts analog signals to digital signals for processing by PLCs or other control systems
-Communication Protocols: Supports standard communication interfaces like Profibus, Modbus, and HART
-Resolution: 12-bit, providing high-precision analog signal measurement
Communication protocols: Support a variety of communication protocols, including TCP/IP, UDP/IP, Modbus TCP/IP, EtherNet/IP, PROFINET, PROFIBUS DP, CANopen, Modbus RTU, etc.
Transmission rate: Depending on the communication protocol, the transmission rate varies, such as PROFIBUS DP can reach 960 kbps to 6 Mbps, CANopen can reach 125 kbps to 1 Mbps, Modbus RTU can reach 9600 bps to 115200 bps.
Number of nodes: The maximum number of nodes supported also varies according to the communication protocol, such as PROFIBUS DP maximum 31 nodes, CANopen maximum 127 nodes, Modbus RTU maximum 255 nodes.
Power supply: Usually 24 VDC.
Power consumption: 2 W.
Number of channels: When used as a digital input module, the number of channels may be 16.
Measuring range: 2.0KN (kN)
Measurement accuracy:
Battery powered: ±0.5%
AC220V power supply: ±0.25%
Supply voltage: 24V (some information may also include other supply options, such as AC220V)
Current: 100-400A (This current range may be suitable for specific application scenarios or device models, further confirmation is required)
Input voltage:
For the DC version, the input voltage is usually 220VAC.
For other types of controllers, there may be different voltage requirements, such as 24VDC.
Output voltage:
The output voltage of the DC supply version is 0-10VDC.
Output power: 800W (DC version).
Current: 100-400A (some information mentioned, but may be specific to specific application scenarios).
specification
Working temperature:
The operating temperature of the DC power supply version is -10℃ to +45℃.
Control mode: PID control, fuzzy control, adaptive control
Input signal: analog (0-10V, 4-20mA), digital (ON/OFF)
Output signal: analog (0-10V, 4-20mA), digital (ON/OFF)
Control accuracy: ±0.1%FS
Communication interface: RS485, Modbus, Profibus
Supply voltage: AC220V/DC24V
Operating temperature: -10℃~+55℃
Type: Communication equipment in industrial automation systems, especially the RTU (Remote Terminal Unit) series.
Communication protocols: Support a variety of communication protocols, such as Modbus, Profibus, etc., to ensure compatibility and efficient communication with different devices.
Processor and Memory: The device is equipped with a high-performance processor and memory capable of processing large amounts of real-time data and performing complex logic and control tasks.
Input voltage: AC 100-240V, indicating that it is suitable for a wide range of AC input voltages, suitable for power supply standards in different regions.
Output voltage: DC 24V, indicating its output stable DC voltage.
Output current: 4.5A.
Power: 105W.
Operating temperature: -25℃~+70℃, indicating that it can work normally in a wide temperature range.
Input voltage: 100-240V AC, 50/60Hz, indicating that it is suitable for a wide range of AC input voltages.
Output voltage: 24V DC, indicating its output stable DC voltage.
Output current: 6.3A, providing enough current output to drive a variety of devices.
Efficiency: 91%, indicating a high energy conversion efficiency.
Power factor: 0.98, indicating a higher utilization of the input power.
specification
Operating temperature: -25℃~+70℃, indicating that it can work normally in a wide temperature range.
Protection category: IP20, provides a certain degree of dust and water resistance.
Certification: CE, RoHS, UL, cUL, indicating that the product has passed a number of international safety and quality certifications.
Quality assurance: 1 year, providing a one-year quality guarantee period.