argument
Processor: 2.6GHz or 2.7GHz dual-core or 2.6GHz quad-core Intel Core i7 5700EQ processor
Memory: 4GB single-channel 1600 MHz DDR3L RAM is standard, expandable up to 8GB
Storage: Integrated hard drive, capacity may vary depending on configuration (e.g. 500GB)
System bandwidth: up to 8 GB/s
Slot bandwidth: 4 GB/s
specification
Type: PXI Embedded controller
Manufacturer: National Instruments (NI)
Operating system: Factory installation Win10(64-bit) and drivers
Size and weight
Dimensions: 115mm x 48mm x 150mm
Weight: Approx. 1.2kg (another saying is 2KG, may vary depending on configuration or version)
series
The PXIE-8840 is part of NI’s PXI family of controllers
Parameters and specifications
Data exchange capability: Up to 10,000 16-bit registers can be used to exchange large amounts of data.
Server connection: Supports three types of server connection, the number of which is 5.
Supported PLC types: PLC2, PLC5, SLC, CLX, CMPLX, MICROLX, etc.
Supported message types: PCCC and CIP.
Client connection: Of the three types of client connections, two are connected and one is not connected.
I/O connections: The number is 2 and the I/O connection size is 248/248.
Maximum RPI time: 5 milliseconds per connection.
Supported CIP services: including 0x4C-CIP data table reading.
Power supply: 24 VDC nominal, allowing range 10 to 36 VDC, allowing positive, negative, GND terminals.
Current load: 24 VDC nominal @ 300 mA, 10 to 36 volts DC at 610 mah Max.
Size and weight
Dimensions: 5.38 x 1.99 x 4.38 inches (or 13.67 x 5.05 x 11.13 cm).
Analog input: 8-way differential or 16-way single-ended.
Analog output: 4.
Digital I/O: 48 lines.
Update rate: Up to 1.25 MS/s.
Resolution: 16 bits.
Voltage range: ±10v, ±1v, ±100mv.
specification
Operating temperature: -20 ° C to 55 ° C in some descriptions, while 32 ° C to 90 ° C in others. It depends on the application scenario and product configuration.
Power consumption: 14w Max.
Software support: NI LabVIEW, NI-DAQMX.
Size and weight
Size: 13.4 x 5.0 inches (from search results 3), but there is also information that mentions the outline size of 10.6CM x 9.3CM x 2.3CM (product dimensions may not include frames or connectors, etc.).
argument
Number of channels: Usually 16 differential input channels, but can also support 32 single-ended input channels.
Resolution: There are many terms, including 24-bit analog-to-digital converter, 12-bit and 32-bit. Please note that the specific resolution may vary depending on the product model or configuration.
Sampling rate: The maximum sampling rate is 100 kS/s, but the specific rate may vary according to application requirements.
Input voltage range: ±10 V, suitable for a variety of common signal types and voltage standards.
Input impedance: 1 MΩ || 5 pF to ensure stable signal transmission.
Output voltage: 24VDC in some descriptions, but please note that this may be related to the specific configuration or purpose of the module.
Output points: 8 isolated points, which may refer to the output capability of the module in certain configurations.
specification
Operating temperature range: varies from description to description, such as -40 ° C to 85 ° C or 32 ° C to 90 ° C, depending on the product model and operating environment.
Communication protocols: Support Ethernet /IP and other communication protocols to facilitate data exchange with other devices or systems.
Driver software: Support NI driver software such as DAQmx, which is convenient for users to collect and process data.
argument
Input voltage: 24VDC, but supports a wide range of input voltages, including 85-264V AC, 47-63 Hz or 110-370V DC
Output voltage: 24V DC
Output power: 450 W
Maximum output current: not given directly, but usually related to output power and voltage
Operating temperature range: -40°C to +70°C
specification
Analog input: 4 high-speed analog inputs, each channel 10 MS/s
Analog output: 2-channel 12-bit analog output, 4 MS/s single-channel update rate, 2.5 MS/s dual-channel update rate
Digital I/O: Eight digital I/O lines
Counter/timer: 2 24-bit counters
On-board memory: High capacity on-board memory (32 or 64 MS)
Input range: Extended up to ±42 V
dimension
Physical dimensions: 166mm x 112mm x 36mm
argument
Input voltage: According to the search results, the PCI-7813R supports 24VDC or 125VDC input voltage, but there are also claims that its power supply is 200V, which may refer to the rated voltage range of the power supply system, please refer to the product manual.
Output voltage: 24VDC.
Maximum output current: 10A.
Operating temperature range: -40°C to 70°C, there are also claims that its operating temperature is 32 °C -90 °C, which may be related to different models or configurations.
Sampling period: 100ms.
Number of channels: 32 digital I/O RTSI trigger cables.
specification
Size:
120mm x 60mm x 80mm (one way to say it).
13.4 x 5.0 inches
Weight: 0.5kg
Resolution: 32 bits.
Communication protocol: Support Modbus, Ethernet, OPC, etc.
Support Windows 7, Vista, XP, 2000 and other operating systems
Size and weight
Size: 13.4 x 5.0 inches (based on search results [4])
Weight: approximately 2kg (according to search results [5])
series
The PXIe-6368 belongs to the PXI series of NI data acquisition devices. PCI extensions for Instrumentation (PXI) is a rugged, PC-based measurement and automation system platform designed for industrial automation, test measurement, data acquisition, and more.
argument
Number of channels: Multiple channels are supported, typically 32 single-ended or 16 differential input channels.
Resolution: High-resolution ADCs, capable of providing high-precision data acquisition, are known as 24-bit analog-to-digital converters or 32-bit converters, which may vary by model or version.
Sampling rate: The maximum sampling rate can reach 100 kS/s, but the specific rate may vary according to the application requirements.
Input voltage range: ±10 V, suitable for a variety of common signal types and voltage standards.
Input impedance: 1 MΩ || 5 pF to ensure stable signal transmission.
specification
Brand: NI (National Instruments)
Product type: Data acquisition module
Series: Signal Conditioning eXtensions for Instrumentation (SCXI) series
Parameters and specifications
Voltage: Usually 24Vdc/120Vac, or 24V.
Current: The range may be 100-400A, but please note that this range may vary depending on the specific application scenario.
Output frequency: 50HZ or standard kHz may be supported, depending on the product model and configuration.
I/O connectors: 50-pin connectors may be available.
Resolution: Probably 32 bits.
Size and weight
Weight: 2KG