Communication interface: Supports point-to-point, master/slave, asynchronous, half-duplex, and 1200baud communication with field devices.
Error checking: Parity check for each byte and CRC check for one byte.
Speed: Can request and receive two digital messages per second from field devices.
Signal support: Support for standard 4 to 20mA analog sensor signals and digital HART frequency shift keying (FSK) signals superposed on 4 to 20mA analog signals.
Supported HART meter types: HART meters that comply with version 5, 6 or 7 of the HART specification can be used.
Size and weight:
Size: Specific size information is not explicitly given in the search results, but similar Foxboro modules are likely to be around 140mm x 80mm x 60mm.
Weight: The exact weight information is not explicitly given in the search results, but a similar Foxboro module may weigh about 0.5kg or 0.21kg.
Data transfer rate: The FBM232 supports Ethernet transfer rates of 10 Mbps/100 Mbps.
Communication capability: Can communicate with up to 64 field devices.
Data integration capability: Each card can provide data integration capability of up to 2000 DCI (Distributed Control Interface) modules.
Protocol support: FBM232 has standard data communication drivers (Modbus, ModbusTCP/IP, OPC, etc.), and can also be developed and loaded according to customer needs for specific communication protocols.
Environment adaptability: The FBM232 and its wiring terminals are suitable for installation in Class1Division2 and Zone2 environments and comply with G3 (harsh) environment standards.
Power and Signal: The FOXBORO FBM232 P0926GW controller (PWM and fault) signal is compatible with 5 V CMOS logic and can also be adjusted to 15 V level using an external resistor divider.
Analog input/output channels: The FBM204 has four 20 mA DC analog input channels and four 20 mA DC analog output channels.
Communication: The FBM204 communicates with the main control station via an optional redundant 10Mbps Ethernet-based fieldbus. The fieldbus communication component FCM is used for the conversion between the 2Mbps communication protocol adopted by FBM and the 10Mbps communication protocol adopted by the Ethernet fieldbus.
Accuracy: The accuracy of the input channel is ±0.03 of the range, and the accuracy temperature coefficient is ±50 ppm/ºC.
Conversion time: High precision through Sigma-Delta data conversion, providing a new analog input reading every 25 milliseconds.
Fail-safe configuration: Provides configurable options for fail-safe configuration
Input interface: Contains eight 20 mA DC analog input channels, each of which can accept 2-wire analog sensor inputs, such as 4 to 20 mA transmitters or self-powered 20 mA signal sources.
Accuracy: ±0.05 of the range.
Power requirements:
Input voltage range (redundant) : 26 to 42 volts DC.
Power consumption: 14 W (maximum), heat dissipation: 12 W (maximum).