Showing 481–492 of 655 results

P0926GH

¥4,152.00
Parameters:
Control type: Process control.
Input/output channel: Multi-channel design, support analog and digital input/output.
Control accuracy: high-precision control algorithm to ensure accurate control effect.
Working environment: adapt to harsh industrial environment, with good anti-interference ability.
Communication interface: supports a variety of industrial communication protocols to facilitate data exchange with other equipment.
Power requirements: Adapt to a wide range of power fluctuations to ensure stable operation.
Rated voltage: 230V.
Output frequency: 150.
Specifications:
Weight: 1.24kg.
Specification: 263525 (may refer to size).
Color: Black.
Features: Modules.
Bom number: 2451856.

FBM01

¥4,152.00
Parameters and specifications:
Input interface: Contains eight 20 mA DC analog input channels, each of which can accept 2-wire analog sensor inputs, such as 4 to 20 mA transmitters or self-powered 20 mA signal sources.
Accuracy: ±0.05 of the range.
Power requirements:
Input voltage range (redundant) : 26 to 42 volts DC.
Power consumption: 14 W (maximum), heat dissipation: 12 W (maximum).
Communication: via redundant fieldbus.
Size and weight:
Weight: Approximately 2KG

P0922YU

¥5,262.00
Parameters and specifications:
Power input:
Input voltage range: 85 to 265 volts AC or 108 to 145 volts DC, nominal 125 volts DC.
Input frequency range: 47 to 63 Hz.
Input current: 5.6A (RMS maximum) for 85 V AC input, 2.5A (RMS maximum) for 230 V AC input.
Power output:
Output voltage: 24.0 V DC, 0.2 V DC nominal factory Settings.
Voltage line adjustment rate: 2.0% of Vout.

FBM217

¥6,025.00
Parameters and specifications:
Input channels: 32 independent channels.
Input range (per channel) : open circuit voltage 15-30V dc, short circuit voltage 0-5V dc.
Input impedance: ON-state 1 kW (Max), at 15 V dc; OFF- Status 100 kW (min) at 30V dc.
Communication: Communicate with FCM and FCP through fieldbus.
Power requirements: 24 V dc +5%, -10%.
Power consumption (Max) : 3W (Max) 24V dc.
Heat dissipation (Max) : 5W (Max) at 24V dc.
Current: 4 mA (typical) at 5 to 60 V dc.
Vibration: 0.75g (5 to 200Hz).
Isolation: Channels are isolated from each other and from the ground.

FBM201

¥5,241.00
Parameters and specifications:
Input channels: The FBM201 provides eight isolated and independent analog input channels for receiving analog sensor signals.
Input range:
FBM201:0 to 20 mA DC
FBM201b: 0 to 100 mV DC
FBM201c: 0 to 5 V DC
FBM201d: 0 to 10 V DC
Power consumption: Maximum 7 W.
Heat dissipation: Maximum value is 3 W.
Communication interface: communicates with its associated FCM or FCP via a redundant 2 Mbps module fieldbus.
Working environment:
Temperature: -40 to +70°C (-40 to +158°F)
Relative humidity: 5 to 95% (non-condensing)
Altitude: -300 to +12,000 m (-1,000 to +40,000 ft)

FBM207C

¥6,235.00
Parameters and specifications:
Control function: The FBM207C has 30+20 program control function, which can realize the rise and cooling control of any slope, with programmable/operable commands such as jump (cycle), run, pause and stop, and allow the program to be modified at any time during the control operation of the program.
Adjustment algorithm: The AI artificial intelligence adjustment algorithm with curve fitting function can obtain smooth and smooth curve control effect.
Input support: Support a variety of thermocouples, thermal resistance, linear voltage, current, resistance and radiation (infrared) thermometers, and has the expansion of input socket installation of special input specifications, and can customize the special input nonlinear correction table, can be connected to the external Cu50 copper resistance as thermocouple cold end compensation.
Measurement accuracy: 0.1 (V8.0 version) measurement accuracy, temperature drift less than 50PPm/℃.
Output support: Modular output support SSR voltage, linear current (voltage), relay contact switch, thyristor contactless switch, single-phase, three-phase thyristor zero-crossing trigger, single-phase thyristor phase-shift trigger output that is, position proportional output (directly drive valve motor positive/reverse).

FBM242

¥4,152.00
Parameters and specifications:
Signal output: The FBM242 provides 16-channel external source solid-state switching output with channel isolation, provided by the terminating assembly.
Rated voltage and current:
AC load: Inductive load up to 2A or 20mH at 132V AC (without suppressor).
DC load: Inductive load up to 2A or 50mH at 150V DC (no suppressor).
Surge current: 20A peak, duration is 16 milliseconds.
Leakage current: less than 1mA.
On-resistance: less than 100 milliohm at 20°C.
Heat dissipation: Maximum 7.0W.
Fuse: 5 x 20mm, rated 3.15A (temperature reduced to maximum 2A).
End cable connection: 37 pin male head D-subminiature.
End cable Type: Type 4.
Color: Dark blue, representing discrete type.
Power requirements: Input voltage range (redundancy) 24V dc +5%, -10%, 3W (Max.) for 24V dc consumption, 3W (Max.) for 24V dc heat dissipation.
Size and weight:
Dimensions: Length x width x height 10.4 cm x 4.5 cm x 11.4 cm.
Weight: 0.284 kg.

P0922YU

¥6,205.00
Parameters and specifications:
Input voltage range: 85 to 265 volts AC or 108 to 145 volts DC, nominal 125 volts DC.
Input frequency range: 47 to 63 Hz.
Input current:
5.6A (RMS maximum) for 85 V AC input.
2.5A (RMS maximum) for 230 V AC input.
Output voltage: 24.0 V DC, 0.2 V DC nominal factory Settings.
Voltage line adjustment rate: 2.0% of Vout.
Leakage current: When operating at 250 V AC (47 to 63 Hz) or lower, the AC line to chassis grounding is less than 1.6 mA.
Size and weight:
Dimensions: Approximately 17.8 cm x 10.7 cm x 21.5 cm (height x width x depth).
Shipping weight: 6 kg.

P0904HA

¥6,235.00
Parameters and specifications:
Input voltage: 100/120/220/240 VAC Optional input.
Output voltage: 39 VDC output.
Data capacity: 16MB (mentioned in some messages, but not in all results).
Operating voltage: 12.5-42VDC (mentioned in some information, but not in all results).
Size and weight:
Size: The specific size is not directly given, but the general industrial power module size is moderate, easy to install and integrate.
Weight: 5.00lb

FEM100

¥4,152.00

Parameters and specifications
Measurement principle: Based on Faraday’s law of electromagnetic induction. When a liquid flows through a magnetic field perpendicular to the direction of flow, the flow of the conductive liquid induces a voltage proportional to the average velocity (that is, the volume flow).
Electrode materials: such as 316L (stainless steel), Hc (Hastelloy C), Ti (titanium), Ta (tantalum), etc.
Lining material: such as F4 (polytetrafluoroethylene), PUR (polyurethane rubber), etc.
Accuracy: 0.5 or 1.0 (depending on the caliber).
Repeatability: ±0.1% measurement value.
Operating voltage: 220VAC±10% or 24VDC±10%.
Output signal: Current (4… 20mA) and pulses (frequency 0-1KHZ).
Working pressure: DN10-DN65: ≤2.5Mpa, DN80-DN150: ≤1.6Mpa, DN200-DN1200: ≤1.0Mpa.
Medium temperature: Depending on the lining material, the range is roughly -20℃ to 180℃.
Ambient temperature: ≤85%RH (20℃).

FBM216

¥5,268.00
Parameters and specifications
Type: Communication redundant input interface module
Brand: FOXBORO
Origin: Probably from Switzerland or Pudong, Shanghai, China
Voltage: 24Vdc±5%
Current: In the range of 0-20.4mA per channel, but up to 33mA per channel
Accuracy: ±0.075% of the range
Input: 8 independently isolated channels supporting 4-20mA standard signals or HART devices
Communication: FCM is connected via component fieldbus and supports HART V6
Power requirements: Input voltage range 24Vdc±5%, consumption 7W (Max), heat dissipation 4W (Max)
Loop power supply protection: Each channel is completely isolated between channels, current limiting and voltage adjustment
Operating temperature: -20 to +70 degrees Celsius (-4 to +158 degrees Fahrenheit)
Size and weight
Dimensions: 10.4 cm x 4.5 cm x 11.4 cm

FBM201

¥4,151.00

Parameters and specifications
Product type: Analog input interface module.
Input type: General purpose (analog sensor signal).
Number of analog input channels: 8.
Input range:
FBM201:0 to 20 mA DC
FBM201b: 0 to 100 mV DC
FBM201c: 0 to 5 V DC
FBM201d: 0 to 10 V DC.
Power consumption: 7 W (Max).
Heat dissipation: 3 W (Max).
Operating temperature: -40 to +70°C (-40 to +158°F).
Relative humidity: 5 to 95% (non-condensing).
Altitude: -300 to +12,000 m (-1,000 to +40,000 ft).