The PROSOFT MVI56-MNETC module is a general-purpose networking module for industrial applications. It provides seamless connectivity between different devices and networks, allowing efficient data sharing and communication.
** Product parameters: **
– Model: MVI56-MNETC
– Power supply: 5v DC
– Communication protocol: Modbus TCP/IP
– Network interface: Ethernet
– Operating temperature: -40°C to 85°C
– Size: 4.88″ x 3.88 “x 1.38”
Prosoft 5302-mbp-mcm4module is designed to provide reliable and reliable communication between different devices in the industrial control system. It has a compact and durable design, making it suitable for use in harsh industrial conditions.
Product parameters (s)
– operating voltage: 10 to 30 v dc
– power consumption: Max. 4 w
– operating temperature: -40 c to 85 c
– storage temperature: -40 c to 85 c
Interface type: Supports Modbus TCP/IP and Modbus RTU/ASCII protocols
Data rate: The data rate may vary for different protocols or versions. For example, in the PROFIBUS DP version, data rates can reach 9600 to 384000 bps
Voltage: Working voltage is 24VDC, support PLC power supply or external power supply
Power consumption: Power consumption may vary in different configurations, but is usually lower, such as 2 watts or a maximum of 3.5W
specification
Construction form: Designed for the Allen-Bradley ControlLogix series PLC, it can be mounted directly onto the backplane of the ControlLogix controller
Connection type: 9-pin D connector
Overall dimensions: 175 mm x 89 mm x 25 mm
Supported protocols: PROFIBUS DP-V0 and DP-V1
Number of connected devices: up to 125 slave devices (via repeater)
Loop byte input/output: up to 1536 loop bytes input and 1536 bytes output data
Function: Used as an input/output module between the PROFIBUS network and the ControlLogix processor, supporting the full master station specification according to IEC 61158.
Communication: Support PROFIBUS DPV0/V1 protocol, acyclic parameter data can be transmitted through Class 1 or Class 2 DPV1 services.
Data transfer: The processor’s data transfer is asynchronous from the I/O data transfer on the PROFIBUS network.
Database: A user-defined database is stored in the module to hold the data required by the protocol.
Ladder logic: Used for data transfer between modules and processors, including sample ladder diagram files (additional instructions).
Backplane: Single slot – 1756 backplane compatible.
Communication protocol: Support for Modbus serial /ASCII communication protocol, which is a widely used industrial automation communication standard. In addition, it also supports Modbus TCP/IP, EtherNet/IP, DF1 and other communication protocols.
Interface: The module is equipped with dual RS232 serial application ports that support the RS232/RS485 and RS422 electrical standards.
Baud rate: can be configured from 110 baud to 115.2 kbps, according to the actual application requirements.
Serial Settings: Supports a variety of serial Settings, including none, odd or even parity, data bits 5, 6, 7 and 8, and stop bits 1 or 2.
Operating temperature range: -40℃ to +85℃.
Storage temperature range: -40℃ to +85℃.
Power Supply: 24VDC nominal (9-30VDC)
Power consumption: Maximum 2.5W
Operating temperature: -40℃~ +70℃ (-40°F ~ +158°F)
Storage temperature: -40°C ~ +85°C (-40°F ~ +185°F)
Relative humidity: 5% ~ 95% (non-condensing)
Data rate: up to 12mbps
Number of PROFIBUS DP-V1 slaves supported: A maximum of 125
Interface: One or two PROFIBUS DP-V1 interfaces
Supported range data types: 3x, 4x
Type. PROFIBUS master station module.
Function. Used as a PROFIBUS network scanner to transfer input and output data between PROFIBUS devices and processor data.
Identify. It is recognized as an input/output module and has access to processor memory for data transfer between the processor and the module.
Correspondence. Supports the PROFIBUS DPV0/V1 protocol and can be transmitted via Class 1 or Class 2 DPV1 services.
High stability and reliability: The module can perform well in a variety of industrial environments, with a high degree of stability and reliability, ideal for use in complex industrial application scenarios.
Model : PTQ-PDPS
Product type : slave station DP interface module
three, the role
main functions : Provides PROFIBUS DP V0 slave station protocol interface to realize efficient data transmission with master station equipment, and provides reliable solutions for industrial automation
. Parameter
protocol supported: PROFIBUS DP V0 slave protocol
data transmission : powerful data transmission capabilities, support user configurable data mapping and DP port operations
I/O : up to 244 bytes of input and output data, up to 400 bytes in total
Prosoft 5302-mbp-mcm4 is a high-performance modbus plus transducer of modbus protocols. It can connect modbus plus to TCP/IP and modbus rtu, providing flexible integrated solutions. The map is widely used in areas such as control systems, industrial automation and data collection.
Product parameters (s)
– communication interface: modbus plus, modbus TCP/IP, modbus rtu
– operating voltage: 10-30vdc
– working temperatures: – 40 c – 85 c
– maximum number of connections: 32 modbus plus nodes
– transmission speed: 10/100 MBPS Ethernet, 10 MBPS modbus plus
Operating voltage: According to the search results, there are two versions of 220V and 345V, which may vary depending on the module model or application scenario.
Output frequency: There are 3535Hz and 50HZ, depending on the module configuration.
Main processor: 32bit.
Temperature range: -40°C to +85°C.