PROSOFT MVI56-PDPMV1 is a communication interface module for industrial automation. Developed by Prosoft Technology, the product is designed for communication and data exchange with Rockwell Automation’s ControlLogix PLC system. The following is detailed information about the product parameters, specifications and application areas of the PROSOFT MVI56-PDPMV1, together with the corresponding Russian translation:
Product parameters and specifications:
Model: MVI56-PDPMV1
Compatibility: Compatible with the ControlLogix platform, it is a Profibus DP V1 compatible module
Communication interface: Has an optically isolated RS485 port that supports PROFIBUS DP Version 1 protocol
Connection capability: Up to 125 PROFIBUS slave devices can be connected to this port
Configuration capability: Configures up to 1536 cycle bytes and 1536 output bytes
Additional features: including alarm handling, synchronization and freeze commands, support for PROFIDrive version parameter read and write operations, multicast and broadcast telegrams
PROSOFT MVI56-BAS is a BASIC communication module, the following are its parameters, specifications, dimensions, weight, series, features and functions:
Parameters and specifications:
Voltage: 24VDC.
Operating temperature: -40℃ to 85℃.
Storage temperature: -40℃ to 85℃.
Relative humidity: 5% to 95% (no condensation).
Size and weight:
Product size: 117mm x 43mm x 129mm.
Weight: 0.91kg.
Series: This module is manufactured by Prosoft Technology and belongs to the MVI series of communication modules.
Features:
Flexibility: Provides flexible configuration options, compatible with a variety of communication protocols and network interfaces, such as Modbus TCP/IP, Ethernet/IP, etc.
PROSOFT MVI56-PDPMV1 – Description, Parameters, Specifications, Dimensions, Weight, Series, Features, Functions, Applications, and Use Cases
Description:
The PROSOFT MVI56-PDPMV1 is a PROFIBUS DP V1 master communication module designed for seamless communication and data exchange between PROFIBUS devices and processors.
Parameters:
Communication Interface: PROFIBUS DP V1
Module Type: Master Communication Module for PROFIBUS
Protocol Support: IEC 61158
Database: User-defined, stored within the module for preservation of protocol-specific data
Measurement, Resolution, Accuracy: Specified based on specific requirements
Specifications:
Module Type: Input/Output
Processor Memory Access: Enabled for data transfer between the processor and the module
Ethernet Interface: Supports use of Rockwell Automation’s Ethernet interface for communication
PROSOFT MV169-PDPMV1 is a programmable logic controller (PLC) module manufactured by ProSoft Technology. It offers a range of specifications, features, and applications tailored for various industrial automation control tasks. Here is an overview of its parameters, specifications, dimensions, weight, series, features, and functions in English:
Parameters and Specifications:
Communication Protocols: Supports various communication protocols such as Ethernet/IP, Modbus TCP/IP, and DeviceNet, enabling seamless integration with different devices and controllers.
Compatibility: Compatible with multiple PLC brands and models, including Rockwell Automation’s ControlLogix and CompactLogix series controllers.
Data Mapping: Provides data mapping capabilities for fast and accurate data transmission and interpretation between different communication protocols.
Dimensions and Weight:
Exact dimensions (length, width, height) and weight may vary, but typically, PLC modules are designed for compact installation in industrial environments. It is recommended to refer to the official documentation or manufacturer’s website for precise measurements and weight.
Series:
MV169-PDPMV1 belongs to the MVI69 series of communication modules by ProSoft Technology.
Operating voltage: 220V (based on search results)
Output frequency: 350kHz
I/O point: 120 (mentioned in some descriptions)
Supported PLC types: PLC2, PLC5, SLC, CLX, CMPLX, MICROLX
Supported CIP services: 0x4C-CIP data table read, 0x4D-CIP data table write, etc
The software can configure communication parameters, including baud rate, parity check, data size, stop bit, and so on
specification
Type: Modbus TCP/IP controller gateway to PROFINET
Mounting method: Separate DIN rail mounting module
Port: Provides two Ethernet ports for communication, remote configuration, and diagnosis
Onboard SD card slot: Used to store configuration files, support recovery, transfer of configuration files to another gateway, or general configuration backup
Supported protocols: Modbus RTU/ASCII, Modbus TCP/IP, EtherNet/IP, etc.
Configuration capability: Each MVI56E port can be configured as a host or slave.
Storage capacity: User-definable modular data memory mapping of up to 10,000 16-bit registers.
Network configuration: 10/100 MB Ethernet port for network configuration and diagnostics with automatic cable cross detection.
specification
Operating temperature: Designed for standard process applications, the MVI56E-MCMXT is designed for the Logix-XT control platform, allowing operation in extreme environments.
Compatibility: Backward compatible with previous MVI56-MCM versions, replacement can be done without changing existing controller programs.
Display and diagnosis: 4-character, scrolling, alphanumeric LED display displays status and diagnostic data in plain English.
argument
Power Supply:
Some versions support 24VDC.
Some versions support AC 100-240V, 50/60Hz.
Output voltage: DC 12V/3.3V (specific version).
Power: 50W (specific version).
Communication interfaces: RS-232, RS-485, Modbus TCP/IP, and TCP/IP (specific version).
specification
Shell material: metal material.
Size:
120mm x 80mm x 30mm
220mm x 180mm x 50mm
100mm x 80mm x 30mm
1.Parameters:
–Supported Modbus Clients: Up to 3012
–Supported Modbus Servers: Up to 2012
–Ethernet Port: 1 x 10/100 Mbps Ethernet port1
–Power Consumption: 800mA at 5VDC or 3mA at 24VDC1
–Software Requirements: ProSoft Configuration Builder (PCB) for configuration12
2.Specifications:
–Model: MVI56E-MNETC12
–Brand: ProSoft Technology12
–Compatibility: Specifically designed for ControlLogix platforms12
–Memory: 10,000 words, 16-bit integers