Parameters and specifications
Brand: Honeywell/ Honeywell.
Model: 51303940-250.
Usage: Mainly used in distributed control system (DCS), as a digital input module.
Features: All unnecessary protocols and services have been eliminated internally to avoid the exposure of network security vulnerabilities.
Size and weight
Size: There are several different size descriptions, such as 1/16 DIN, 1/32 DIN, 1/8 DIN, 1/4 DIN, etc., but these descriptions may not correspond directly to the specific physical size.
Weight: Approximately 0.78KG.
Parameters and specifications
Support system: PLC (Programmable logic Controller).
Features: Input/output module, support fiber transmission Profibus DP bus.
Power supply: DC9-36V wide redundant dual power supply, DC1500V power isolation, reverse protection.
Communication interface:
Supports logically independent dual Modicon S908 RIO buses.
One or two S908 RIO F-female electrical ports and one or two 155M optical fiber ports.
The fiber link and power supply fault relay generates an alarm.
Protection:
Electrical interface 4000V lightning protection, 1.5A overcurrent, 600W surge protection.
IP30 protection grade, corrugated aluminum reinforced case.
Size and weight
Size: 22cm
Weight: 0.2kg
Current: 100-400A (note, however, that this may not be the same as the operating current of the module itself, but rather refers to the current range of certain systems or devices to which the module may be applied).
Weight: about 2KG.
Delivery time: In stock (meaning available from stock).
Input function: It can receive input signals from field equipment, such as fire alarm signals of smoke detectors, opening and closing state of doors and Windows, etc. These input signals are processed and sent to the main controller of the safety system.
Output function: can receive the output instructions from the autonomous controller, and convert these instructions into appropriate control signals to control the field equipment. For example, when the controller receives a fire alarm signal, it can send instructions through the FC-SCNT01 module to make the door lock automatically open or activate the evacuation alarm.
Communication interface: Use standard communication protocols to communicate with the master controller to ensure reliable transmission of data in the system.
Voltage: The power supply voltage ranges from 12 to 40VDC. 24VDC is recommended.
Power consumption: DC12-35V, HART part less than 2.5mA.
Communication interface: pure hardware conversion, small delay, high efficiency. Support Bell202 standard FSK frequency shift keying signal with 1200Hz and 2200Hz carrier. HART and field device communication interface customization is supported (however, please note that CC-PAOX01 itself does not support HART protocol).
Data communication: magnetic isolation can effectively ensure data accuracy.
Communication mode: Half duplex communication (1200, ODD, 8, 1).
Parameters and specifications
Model: FC-SDO-0824 V1.3
Brand: Honeywell
Input voltage: 24VDC
Output voltage: 24VDC
Output current: 0.5A/ channel
Digitized output: 24 channels (however, please note that this contradicts the 8 channels mentioned in the search results [2] and may require further confirmation)
Communication interface: RS-485
Operating temperature: -20℃~70℃
Storage temperature: -40℃~85℃
Size and weight
Dimensions: 120mm x 75mm x 43mm
Weight: 300g
Digital output: 8 channels (some information says 24 channels, but based on other information, this may be related to a specific application or configuration)