YNT512D
¥3,526.00Parameters and specifications:
Voltage: Usually 24V.
Current: Support range from 100A to 400A.
Application: It can be applied to DI820, DI821, DI825, DO820, DO821 and AI825 I/O modules.
Size and weight:
Weight: Approximately 2KG.
Voltage: Usually 24V.
Current: Support range from 100A to 400A.
Application: It can be applied to DI820, DI821, DI825, DO820, DO821 and AI825 I/O modules.
Weight: Approximately 2KG.
Input voltage specification: 24V DC.
Load voltage: 24VDC, 50mA.
External voltage range: 20.4~26.4VDC.
Maximum output voltage ON: 2V DC.
Maximum leakage current when output is OFF: 0.1mA.
Maximum load current: 100mA/ channel, 26.4V.
Number of channels: 32 channels (digital output)
Communication protocol: Support RS-422/RS-485 communication protocol, dual port, communication rate range of 1200bps to 115.2kbps.
Input/output signals: 0-10VDC, 4-20mA DC, 1-5VDC, 2-10VDC, etc.
Measuring range: 0-9999.
Accuracy: ±0.5% F.S.
Power supply: 24VDC±10%.
Size: 48mm x 96mm.
Installation mode: wall hanging.
Input voltage: 24v DC.
Communication protocol: Support Modbus TCP/IP.
Operating temperature: 40°C to 85°C.
Data acquisition: reliable and accurate.
Size: 100mm long, 50mm wide, 30mm high.
Power parameters such as input voltage range and output voltage range may vary depending on the specific application, but usually involve current, voltage, power factor, etc.
The operating frequency of the power module is high, generally 300KHz~1MHz.
The power density of the power module is large, generally 5~10W/ cubic centimeter.
Sizes may vary depending on the specific model or configuration. Some say it is 145mm x 220mm x 50mm, and another says it is 7.6cm x 5.3cm
Input voltage: 24VDC
Communication protocol: Modbus TCP/IP
Analog input channels: 8
Analog output channels: 4
Digital input channels: 16
Digital output channels: 8
Operating temperature range: 10°C~60°C
Storage temperature range: -20°C to 70°C
Humidity range: 10% to 90%RH (non-condensing)
Accuracy: ±16 microamps (for input current)
Data refresh period: 10ms
Supply power to the transmitter: 24.0~25.5V (output current 25mA)
– type the signal: analog, digital
– type of output signal: analog, digital
– control scheme: pid control, blurred image control, forecasting control, etc.
– communication interface: rs-485, Ethernet, modbus, etc.
– operating temperature: – 20 PPM
– supply voltage: ac 100-240v
Number of channels: 16.
Input signal type: 0-10V, 4-20mA.
Resolution: 16 bits.
Sampling frequency: 100Hz.
Power supply voltage: 24VDC.
Size: 228mmx133mmx35mm.
Weight: 500g.
– Analog input channels :8 or 16
– Input type: differential or single-ended
– Input voltage range :±10v, ±5v, ±2.5 V, ±1.25 V, ±0.625 V, ±0.3125 V, ±0.15625 V
– Temperature measurement range :-200 ° C to +1800 ° C
– Strain measurement range :-20000µε ~ +20000µε
– Maximum sampling rate: 1ms /s per channel
– Resolution :16 bits
– Input channels :16
– Input type: differential, single-ended
– Input voltage range :±10v
– Input impedance :1 MΩ
– Sampling rate: 100ks /s per channel
– Resolution :16 bits
– Output channels: two
– Output type: Analog voltage or analog current
– Output voltage range :±10v
– Output current range :0 to 20ma
The SAI143-H63 module is ideal for high-precision measurements in a variety of applications, including power generation, chemical processing and environmental monitoring. It offers high accuracy and stability, and is designed to be easy to use and integrate into existing systems.
– Input channel :16 differential channels
– Input type: voltage, thermocouple, RTD
– Sampling rate: 1ms /s per channel
– Resolution :16 bits
– Accuracy: ±0.1% of the range
– Isolation :250vac
– Power supply mode :24vdc
Model : YOKOGAWA PW301
Type : Communication module/power module
main functions : power monitoring, data acquisition and transmission
communication interface : Ethernet interface, Modbus communication protocol, PROFIBUS 2
voltage : 24V
Current range : 100-400A\
weight : 2KG (or about 2284g), the actual use is very light