Showing 169–180 of 247 results

CP451-10

¥5,262.00

argument
Power supply voltage: 24VDC
Power consumption: 1.5W
Communication interface: RS485
Operating temperature: -10℃~ 60℃
Resolution: Analog input resolution is 12 bits
specification
Analog input channels: 8
Digital input channels: 8
Digital output channels: 8
Analog input range: 0-10V, 0-20mA
Digital input voltage range: 0 ~ 24VDC
Relay output voltage range: 0-24VDC
Maximum switching current: 2A per channel
Communication protocol: Modbus RTU

ALR121-S50

¥5,141.00

Parameters and specifications
Communication protocol: RS-422/RS-485
Number of ports: 2 ports
Communication rate: 1200 bps to 115.2 kbps
Input signals: 0-10VDC, 4-20mA DC, 1-5VDC, 2-10VDC
Output signal: 0-10VDC, 4-20mA DC, 1-5VDC, 2-10VDC
Measuring range: 0-9999
Accuracy: ±0.5% F.S.
Power supply: 24VDC±10%
Size and weight
Size: 48mm x 96mm (width x height)
Weight: Not explicitly given, but usually the weight of the communication module is light, perhaps less than 1kg

CP451-10

¥4,150.00

trait
Multi-channel output: provides 8 digital output channels to support simultaneous control of multiple external devices.
High resolution: While the primary focus is on digital outputs, the associated analog input capabilities (where present) provide high-resolution monitoring options.
Communication capability: Equipped with RS485 communication interface and Modbus RTU protocol for easy data communication and integration with other control systems, PLCS, SCADA systems or networks.
Durability: Industrial-grade durability, stable operation in harsh industrial environments, resistance to vibration, humidity and temperature changes and other conditions.
Flexible programming and configuration: allows programming and configuration in the control system to determine the mode of operation and logic of the output channel.

CP451-10

¥4,150.00

argument
Power supply voltage: 24VDC
Power consumption: 1.5W
Analog input channels: 8 (although the main discussion is digital output, but this module also has analog input function)
Digital input channels: 8
Digital output channels: 8
Communication interface: RS485
Operating temperature: -10℃~60℃

ALE111-S50

¥4,850.00

argument
Module type: 4-wire analog output
Number of channels: 4
Voltage range: 0-10 V
Gain range: 0.1-10
Offset range: -5-5
Communication protocol: Modbus
Power supply voltage: 24 VDC, 12 VDC, 220 VAC

ISC40G-TF-T1-05

¥6,235.00
Parameters and specifications
Measuring range:
Conductivity measurement range: 1μS/cm ~ 1999mS/cm
Minimum range: 100μS/cm
Maximum range: 1999mS/cm
Process temperature:
Operating temperature range: -10℃ ~ 130℃
Process pressure:
Depends on installation conditions, but generally less than 2MPa (300psi)
Process flow rate:
Maximum 5m/s
Cable length:
Optional length: 5m, 10m, 15m, 20m

AAI143-H53 S1

¥6,230.00

argument
Model: AAI143-H53 S1
Manufacturer: YOKOGAWA
Signal Type: Analog input (4 to 20 mA)
Number of channels: 16
Communication protocol: Support HART protocol (digital communication type)
specification
Application: Analog input module in industrial automation control system
Isolation performance: Has the isolation function
Explosion-proof features: May or may not have explosion-proof features (depending on the suffix code)
series
Series: YOKOGAWA AAI series analog input module

SAI143-H63

¥5,262.00

argument
Input signal type: analog signal, digital signal, pulse signal.
Sampling rate: 1 Hz to 100 kHz.
Accuracy: ± 0.01%FS.
Reliability MTTF: over 100,000 hours.
Isolation voltage: up to 1500VAC.
Operating temperature range: -10℃ to +55℃.
specification
Use: Automation.
Brand: YOKOGAWA Yokogawa.
Material: EPS.
Supported system: DCS system.
Mounting method: Standard 35mm DIN rail mounting.
Size and weight
Size: 262612cm.

SAI-1620M

¥6,035.00

Number of channels: 4 (however, please note that there is information indicating that the FC-SAI-1620M has 16 channels, which may be a difference between different models or product lines)
Input type: Analog (4-20mA, 0-10V)
Input impedance: 250Ω
Accuracy: ±0.1%
Safety level: SIL 2/3
Operating temperature: -40°C to +85°C
Storage temperature: -55°C to +90°C
Relative humidity: 5% to 95% (non-condensing)

ALP121-S00

¥4,265.00

argument
Input signal type: analog signal, digital signal, pulse signal
Sampling rate: 1 Hz to 100 kHz
Accuracy: ± 0.01%FS
specification
Working voltage: 220V
System environment: normal temperature
Power: 2700
Support system: PLC/DCS system
dimension
Specification: 263337
Net depth/length: 135 mm

NFPW444-50

¥5,623.00
argument
Recording method: thermal printing
Recording width: 50mm
Recording speed: 0.1mm/ S-100mm /s
Measurement accuracy: ±0.2%
Display mode: LCD display
Communication mode: RS-232, RS-485, USB
Power supply voltage: AC 100-240V
Power consumption: 20W
Operating temperature: 0°C-40°C
Storage temperature: -20°C-60°C
Humidity: 20%-80% (non-condensing)
specification
Brand: YOKOGAWA/ Yokogawa
Model: NFPW444-50

AMM42

¥6,205.00
Parameters and specifications:
Make and Model: YOKOGAWA AMM42
Circuit design: 3-wire circuit design
Output signal: The measured current signal can be converted into a standard 4-20mA DC signal output
Protection function: Equipped with overload protection and short circuit protection and other protection functions to ensure the stable and safe operation of the equipment