The TRICONEX 2201 is an important industrial control module, the following is a specific description of its parameters, specifications, dimensions, weight, series, characteristics and role:
Parameters and specifications:
Model: TRICONEX 2201.
Operating voltage: Bus voltage range is 16V ~ 28V.
Monitoring current: ≤160μA.
Operating current: ≤200μA.
Indicator: Blinking red during input, blinking during inspection, blinking constantly when input, and blinking rapidly when fault occurs (period: 2s).
Wire system: non-polar two bus.
Encoding mode: electronic encoding, can be arbitrarily set between 1 and 252.
The TRICONEX 2381 is an important automation control module, the following is a specific description of its parameters, specifications, dimensions, weight, series, characteristics and functions:
Parameters and specifications:
Voltage: The usual operating voltage is 24V, but there are also 280V specifications.
Current: Depending on the application and requirements, the current range may vary, for example 100-400A.
Weight: Approximately 2KG.
Series:
The TRICONEX 2381 is part of the TRICONEX family of automation control modules.
The TRICONEX 2301 is a high performance safety instrumentation system (SIS). The following are specific information about its parameters, specifications, dimensions, weight, series, features and role:
Parameters and specifications:
Input voltage: Nominal input voltage is 24 VDC, operating voltage range is 15-30 VDC, maximum input voltage is 33 VDC.
Operating temperature: -40℃ to +70℃ or -40℃ to +85℃.
The input thresholds are 0-5 VDC for the Off zone, 6-14 VDC for the transition zone, and 15-30 VDC for the On zone.
Delay: Input delay <10 ms.
Impedance: Input impedance >30 kΩ (without base plate) ≈3 kΩ (with base plate).
Size and weight:
Weight: 3.5kg (2KG in another version).
Series:
The TRICONEX 2301 is part of the TRICONEX family of instrumentation systems.
The TRICONEX 2841 is an important industrial control module, and the following is a detailed description of its parameters, specifications, dimensions, weight, series, characteristics and functions:
Parameters and specifications:
Operating voltage: 24V DC or 280V.
Current: There are many possible current ranges, such as 100-400A.
Power consumption: 2.6W or 5W.
Speed: up to 150MHZ.
Program capacity: 64MB.
Humidity range: can withstand 0-95% humidity.
Certification: Passed a specific product certification, such as CE certification.
Size and weight:
Weight: There are two possible weights, 1.2KG and 0.13kg.
The TRICONEX 2351 is an automation module, and the following is specific information about its parameters, specifications, dimensions, weight, series, features and functions:
The TRICONEX 2401 is an automated backboard module, and the following are specific information about its parameters, specifications, dimensions, weight, series, features and functions:
Parameters and specifications:
Voltage: 24V or 20V, user-selectable input voltage thresholds range from 1.25 to 66V.
Data transfer: 8-bit, 16-bit or 32-bit data transfer.
Communication module: A communication module that supports specific communication protocols and functions.
Size and weight:
Weight: 2KG or 0.8KG (alternative).
Series:
The TRICONEX 2401 is an automated backboard module in the TRICONEX family.
The TRICONEX 2101 is a high performance industrial controller, the following is a specific description of its parameters, specifications, dimensions, weight, series, features and role:
Parameters and specifications:
Input power: 24V DC.
Number of channels: 16 channels
Interface type: Supports RS-232, RS-485, and Modbus interfaces.
Operating temperature: Suitable for -40°C to 70°C working environment.
The TRICONEX 4351B is a serial communication module manufactured by Triconex for use in the Triconex fault-tolerant security system. The following is specific information about its parameters, specifications, dimensions, weight, series, characteristics and functions:
Parameters and specifications:
Processor: 32-bit, 33 MHz processing power.
Memory: Contains 1MB RAM and 4MB flash memory.
Communication protocol: Support a variety of communication protocols, transmission rate up to 19.2 kbps.
Power supply: Voltage is 24V, current range is 100-400A.
Size and weight:
Weight: Approximately 2KG.
Series:
The TRICONEX 4351B is part of the TRICONEX family and is one of many solutions TRICONEX offers for critical control and safety applications.
The TRICONEX 4119A is a Safety Instrumentation System (SIS) redundant power module that belongs to the Trident family of SIS redundant power modules. The following is specific information about its parameters, specifications, dimensions, weight, series, characteristics and functions:
Parameters and specifications:
Input voltage: Support 120VAC or 240VAC input.
Output voltage: Provides stable 24VDC output.
Output current: The maximum output current is 10A.
Redundancy mode: Supports 1+1 or N+1 redundancy mode.
The TRICONEX 3805E is a module for a wide range of industrial automation control systems. The following is specific information about its parameters, specifications, dimensions, weight, series, characteristics and functions:
Parameters and specifications:
Power supply parameters: The input voltage range is usually 100~240VAC, 50/60Hz, and the output voltage is 24VDC. The maximum output current is 5A.
Operating temperature: Depending on the data, the operating temperature range may be different. One way of saying is -40℃~+85℃, the other way of saying is -20℃~+60℃.
Storage capacity: The memory size is 64MB.
Size and weight:
Size: Different data may give different data on its size. One is 279mm x 127mm x 127mm, another is 130mm x 100mm x 50mm, and another is 140mm x 95mm x 82mm.
Weight: Again, the data given by different sources regarding its weight may vary. One says 2.3kg, another says 1kg, and another says 0.7kg.
The TRICONEX 3700A is a widely used module in industrial control systems, mainly for data communication and system control. The following is specific information about its parameters, specifications, dimensions, weight, series, characteristics and functions:
Parameters and specifications:
Input voltage: The TRICONEX 3700A’s input voltage can be 24VDC or 125VDC, depending on the application scenario and configuration.
Output voltage: The output voltage is usually 24VDC.
Maximum output current: Depending on the configuration, the maximum output current can reach 10A.
Operating temperature range: The TRICONEX 3700A can operate in a temperature range of -40°C to 70°C.
Size and weight:
Size: The TRICONEX 3700A is typically 120mm x 60mm x 80mm, or other similar sizes.
The TRICONEX 3636R is a high-performance safety system designed for critical applications. The following is specific information about its parameters, specifications, dimensions, weight, series, characteristics and functions:
Parameters and specifications:
Input voltage: Usually 24V DC.
Operating temperature range: from -40℃ to +70℃.
Power consumption: Maximum 1.5W.
Communication protocol: Support Modbus RTU/ASCII.
Number of channels: Usually 16.
Input type: Numeric type.
Size and weight:
Size: The exact size may vary depending on the production batch or version, but a common one is 55mm x 105mm x 120mm.