The TRICONEX8310 is a 32-channel triple modular redundancy (TMR) digital input (DI) module from Schneider Electric’s Triconex 8300 series, tailored for Tricon V10/V11 safety controllers in SIL 3 safety instrumented systems (SIS). It supports 24-125 VDC dry/wet contacts with 2oo3 voting for fault tolerance, and optical isolation per channel to shield against surges and noise. The TRICONEX8310 integrates with TriStation 1131 engineering software for channel-level diagnostics (open/short circuits) and real-time monitoring, with <10ms response time for critical safety actions. Its hot-swappable design allows maintenance without system shutdown, and TÜV certification ensures compliance with IEC 61508/IEC 61511. The TRICONEX8310 operates in -40°C to +70°C with 5g vibration resistance, ideal for harsh industrial settings. It delivers 99.99% availability via redundant voting and on-line diagnostics, minimizing unplanned downtime in ESD, BMS, and F&G systems. The TRICONEX8310 is a cost-effective choice for safety-critical DI expansion, combining TMR reliability with seamless Tricon platform integration.
The TRICONEX 9761-210 is a critical digital output module for the Triconex Tricon safety instrumented system (SIS), now part of the Schneider Electric portfolio. This module is designed to provide ultra-reliable, fail-safe output control for critical field devices such as solenoid valves, motor starters, and alarm annunciators in safety applications. Engineered with Triple Modular Redundant (TMR) architecture, the TRICONEX 9761-210 ensures that safety shutdown commands are executed with the highest level of integrity and availability, even in the presence of a hardware fault.
converting plant AC or DC power to the precise, regulated DC voltages required to operate the Tricon main processor, I/O modules, and communication cards within a single chassis. The TRICONEX 8110 is engineered with the same focus on fault tolerance and reliability as the logic solvers it supports, ensuring a clean and continuous power source for mission-critical safety functions. It is a hot-swappable, redundant component, allowing for maintenance or replacement without interrupting the operation of the safety system. The proper functioning of the 8110 is foundational to the availability and integrity of the entire Tricon safety loop.
TRICONEX 3625C1 is a critical communication module manufactured by Triconex, a division of Schneider Electric, specifically for use in their high-integrity, fault-tolerant safety instrumented systems (SIS) and critical control systems, most notably the Tricon and Trident controller platforms. This module serves as a communication interface between the Triple Modular Redundant (TMR) main processors and other subsystems, such as engineering workstations, Human-Machine Interface (HMI) stations, or Distributed Control Systems (DCS). Its primary function is to ensure reliable, deterministic data exchange in environments where system availability and safety are paramount. The TRICONEX 3625C1 module is engineered with the same rigorous reliability standards as the main controllers, featuring diagnostics and fault-tolerance to maintain communication integrity.
The TRICONEX D28799-005 is a specialized safety-certified circuit board, most commonly functioning as a Termination or Barrier Module within the Triconex safety instrumented system (SIS) architecture. It serves as a critical interface point, providing signal conditioning, isolation, and secure termination between field wiring and the system’s central safety controller, ensuring the integrity of signals in high-reliability environments.
The TRICONEX PLM3900N is a critical module within the renowned Triconex family of high-integrity safety instrumented systems (SIS) and critical control systems. Manufactured by Schneider Electric, this module is engineered for applications where maximum reliability, fault tolerance, and safety are non-negotiable. The TRICONEX PLM3900N plays a vital role in systems designed to prevent hazardous events and mitigate their consequences.
The TRICONEX 4000093-145 is a critical analog input module designed for use within the Triple Modular Redundant (TMR) safety instrumented systems (SIS) manufactured by Triconex, a subsidiary of Schneider Electric. This module forms an essential part of the Tricon v9, v10, or Trident controller platforms, which are dedicated to performing high-integrity safety functions such as Emergency Shutdown (ESD) and Fire & Gas (F&G) systems. The primary function of the TRICONEX 4000093-145 is to reliably acquire and condition analog signals from field sensors, such as those measuring pressure, temperature, level, or flow (typically 4-20 mA signals). It features a TMR architecture internally, meaning it processes each input signal through three independent channels, with a two-out-of-three (2oo3) voting mechanism for exceptional fault tolerance. The robust design of the 4000093-145 module ensures continuous and accurate monitoring of critical process variables, enabling the main safety controller to make deterministic decisions to prevent hazardous events in industries like oil & gas, petrochemicals, and power generation.
The TRICONEX 9566-810 is a critical communication and main processor module for the Tricon v9/v10 series, a high-integrity safety instrumented system (SIS) and critical control platform from TRICONEX (now part of Schneider Electric). This module acts as the central nervous system of a Triple Modular Redundant (TMR) controller, executing the safety logic program and managing communication between the three redundant chassis. The 9566-810 is engineered for maximum fault tolerance and reliability in the most demanding safety applications. Implementing the TRICONEX 9566-810 ensures the controller can perform its vital protective functions without compromise.
The TRICONEX AI6700 is a specialized 16-Channel Analog Input Module designed for the Triconex Tricon safety instrumented system (SIS). This module, the TRICONEX AI6700, is engineered to acquire critical process analog signals—such as 4-20 mA, 0-5 VDC, or 0-10 VDC—in a high-integrity, fault-tolerant architecture. Its primary function is to convert these field sensor signals into digital data for the Triple Modular Redundant (TMR) safety controller, enabling continuous monitoring of process variables like pressure, level, flow, and temperature for safety-related functions. The design of the TRICONEX AI6700 emphasizes high accuracy, comprehensive diagnostics, and robust isolation to meet the stringent requirements of Safety Integrity Level (SIL) 3 applications.
The TRICONEX 1600071-001 is a specialized digital output module from the Triconex (a Schneider Electric brand) range of safety instrumented systems, specifically designed for their TMR (Triple Modular Redundant) Tricon or Trident controller platforms. This module serves as a critical safety-rated interface between the fault-tolerant logic solver and field actuation devices such as solenoid valves, motor starters, and alarm annunciators in safety shutdown systems. The primary function of the TRICONEX 1600071-001 is to receive processed, voted commands from the triple-redundant main processors and convert them into robust, isolated, and high-integrity output signals to drive final elements. Its design embodies the TMR principle, where three independent output channels are used to control a single field device, and a 2-out-of-3 voting logic is performed either internally or externally to ensure a single point of failure does not prevent a safe shutdown. The integration of this module into a safety loop is governed by rigorous safety lifecycle standards to ensure it meets the required Safety Integrity Level (SIL).
The TRICONEX 9662-610 is a critical power supply module for the Triconex Tricon v9 (or later) series, a leading Triple Modular Redundant (TMR) safety instrumented system (SIS) from Schneider Electric. This module is not a standard power supply but a specialized, fault-tolerant component designed to deliver clean, reliable, and redundant power to the entire Tricon controller chassis. The primary function of the TRICONEX 9662-610 is to convert the plant’s main AC or DC supply into the isolated and regulated DC voltages required by the system’s triple-redundant main processors, I/O modules, and communication cards. Its design is integral to the overall high availability and safety integrity of the Tricon system, as any power disturbance can compromise the controller’s ability to execute safety logic. The integration of a TRICONEX 9662-610, often in a redundant (N+1) configuration, ensures that the safety system remains operational even in the event of a single power supply failure, maintaining protection for the hazardous process.
The TRICONEX 4329 is a critical 32-Channel Digital Output Module designed for the Triconex Tricon v9, v10, or v11 safety instrumented system (SIS). This module, the TRICONEX 4329, is engineered to provide highly reliable, fault-tolerant output commands from the Triple Modular Redundant (TMR) safety controller to final elements in the field, such as solenoid valves, shutdown valves (SDV), and alarm annunciators. Its primary function is to translate the safety logic’s voted digital decisions into physical, isolated output signals to actuate critical safety devices. The TRICONEX 4329 implements TMR architecture internally, with three independent output circuits per channel that are voted upon at the module’s output terminals, ensuring that no single point of failure can prevent a safe shutdown command. The design of the TRICONEX 4329 is focused on achieving the highest Safety Integrity Level (SIL 3) for emergency shutdown (ESD) and fire and gas (F&G) systems.