Description
Product Description
Product Parameters
| Parameter | Specification |
|---|---|
| Model | TRICONEX 8310 |
| Type | 32-channel TMR Digital Input (DI) Module |
| Platform | Tricon V10 / V11 Safety Controllers |
| Input Channels | 32 channels (24-125 VDC, dry/wet contacts) |
| Input Voltage | 24–125 VDC (nominal) |
| Safety Certification | IEC 61508 SIL 3, IEC 61511, TÜV-certified |
| Voting Logic | 2oo3 (2 out of 3) redundancy |
| Response Time | <10 ms per channel |
| Isolation | Optical isolation (field-to-internal) |
| Diagnostics | On-line channel fault detection (open/short) |
| Redundancy | Hot-swappable in redundant chassis |
| Operating Temp | -40°C to +70°C |
| Vibration | 5g peak (20-500 Hz) |
| Dimensions | 102×356×229 mm |
| Weight | 1.1 kg |
| Certifications | CE, UL, RoHS |
Advantages and Features
- TMR Redundancy: The TRICONEX 8310 uses 2oo3 voting for fault tolerance, ensuring safe operation even with single-channel failures.
- Rapid Response: <10ms channel response time enables quick safety actions in emergency shutdown scenarios.
- Hot-Swappable Design: Allows module replacement without system shutdown, reducing maintenance downtime.
- Comprehensive Diagnostics: On-line monitoring detects open/short circuits and channel faults for proactive maintenance.
- Harsh-Environment Reliability: Operates in -40°C to +70°C with 5g vibration resistance for industrial durability.
Application Cases in Application Fields
- Oil & Gas ESD: The TRICONEX 8310 monitors 32 emergency shutdown contacts in a 200k barrel/day refinery, using 2oo3 voting to avoid false trips and cutting unplanned downtime by 30%.
- Chemical Plant BMS: It connects flame detectors and gas sensors to Tricon V11, enabling <10ms response to combustion anomalies and meeting SIL 3 safety requirements.
- Power Generation F&G: The TRICONEX 8310 integrates fire alarm contacts with turbine control systems, supporting hot-swappable maintenance to prevent forced outages.
- Mining HIPPS: It monitors high-integrity pressure protection sensors, with optical isolation shielding against electrical noise in underground environments.
Comparisons with Competing Products
| Feature | TRICONEX 8310 | Competitor A (Honeywell FSC DI Module) | Competitor B (Emerson DeltaV SIS DI Module) |
|---|---|---|---|
| Redundancy | 2oo3 TMR voting | 1oo2 | 2oo3 (optional) |
| Response Time | <10 ms | 15–20 ms | 10–15 ms |
| Hot-Swap | Yes | No | Yes (partial) |
| Channel Count | 32 | 16 | 32 |
| Safety Certification | IEC 61508 SIL 3 | IEC 61508 SIL 3 | IEC 61508 SIL 3 |
| Tricon Integration | Native (TriStation 1131) | Manual mapping | Gateway required |
Selection Suggestions and Precautions
- Selection Suggestions
- Choose the TRICONEX 8310 for Tricon V10/V11 SIS needing 32-channel DI with 2oo3 redundancy and SIL 3 compliance.
- Pair with redundant Tricon controllers for ESD/BMS/F&G systems requiring hot-swappable maintenance.
- Prioritize for applications needing <10ms response and on-line diagnostics to enhance safety and reduce downtime.
- Precautions
- Use 24-125 VDC input to avoid damaging the TRICONEX 8310 or causing voting errors.
- Calibrate channels quarterly to maintain <10ms response and 2oo3 voting integrity.
- Follow ESD protocols during hot-swap to protect TMR circuitry and communication ports.
- For new projects, ensure compatibility with Tricon V10/V11 firmware; the TRICONEX 8310 is not compatible with Trident controllers.
![]()
1756-L71/A PLC
1756-L74/A PLC
TCM4351B PLC
3805E PLC

Reviews
There are no reviews yet.