TRICONEX 8310

¥999.00

The TRICONEX 8310 is a 32-channel triple modular redundancy (TMR) digital input (DI) module from Schneider Electric’s Triconex 8300 series, tailored for Tricon V10/V11 safety controllers in SIL 3 safety instrumented systems (SIS). It supports 24-125 VDC dry/wet contacts with 2oo3 voting for fault tolerance, and optical isolation per channel to shield against surges and noise. The TRICONEX 8310 integrates with TriStation 1131 engineering software for channel-level diagnostics (open/short circuits) and real-time monitoring, with <10ms response time for critical safety actions. Its hot-swappable design allows maintenance without system shutdown, and TÜV certification ensures compliance with IEC 61508/IEC 61511. The TRICONEX 8310 operates in -40°C to +70°C with 5g vibration resistance, ideal for harsh industrial settings. It delivers 99.99% availability via redundant voting and on-line diagnostics, minimizing unplanned downtime in ESD, BMS, and F&G systems. The TRICONEX 8310 is a cost-effective choice for safety-critical DI expansion, combining TMR reliability with seamless Tricon platform integration.

Category:

Description

Product Description

The TRICONEX 8310 is a 32-channel triple modular redundancy (TMR) digital input (DI) module from Schneider Electric’s Triconex 8300 series, tailored for Tricon V10/V11 safety controllers in SIL 3 safety instrumented systems (SIS). It supports 24-125 VDC dry/wet contacts with 2oo3 voting for fault tolerance, and optical isolation per channel to shield against surges and noise. The TRICONEX 8310 integrates with TriStation 1131 engineering software for channel-level diagnostics (open/short circuits) and real-time monitoring, with <10ms response time for critical safety actions. Its hot-swappable design allows maintenance without system shutdown, and TÜV certification ensures compliance with IEC 61508/IEC 61511. The TRICONEX 8310 operates in -40°C to +70°C with 5g vibration resistance, ideal for harsh industrial settings. It delivers 99.99% availability via redundant voting and on-line diagnostics, minimizing unplanned downtime in ESD, BMS, and F&G systems. The TRICONEX 8310 is a cost-effective choice for safety-critical DI expansion, combining TMR reliability with seamless Tricon platform integration.

Product Parameters

Parameter Specification
Model TRICONEX 8310
Type 32-channel TMR Digital Input (DI) Module
Platform Tricon V10 / V11 Safety Controllers
Input Channels 32 channels (24-125 VDC, dry/wet contacts)
Input Voltage 24–125 VDC (nominal)
Safety Certification IEC 61508 SIL 3, IEC 61511, TÜV-certified
Voting Logic 2oo3 (2 out of 3) redundancy
Response Time <10 ms per channel
Isolation Optical isolation (field-to-internal)
Diagnostics On-line channel fault detection (open/short)
Redundancy Hot-swappable in redundant chassis
Operating Temp -40°C to +70°C
Vibration 5g peak (20-500 Hz)
Dimensions 102×356×229 mm
Weight 1.1 kg
Certifications CE, UL, RoHS

Advantages and Features

  1. TMR Redundancy: The TRICONEX 8310 uses 2oo3 voting for fault tolerance, ensuring safe operation even with single-channel failures.
  2. Rapid Response: <10ms channel response time enables quick safety actions in emergency shutdown scenarios.
  3. Hot-Swappable Design: Allows module replacement without system shutdown, reducing maintenance downtime.
  4. Comprehensive Diagnostics: On-line monitoring detects open/short circuits and channel faults for proactive maintenance.
  5. Harsh-Environment Reliability: Operates in -40°C to +70°C with 5g vibration resistance for industrial durability.

Application Cases in Application Fields

  • Oil & Gas ESD: The TRICONEX 8310 monitors 32 emergency shutdown contacts in a 200k barrel/day refinery, using 2oo3 voting to avoid false trips and cutting unplanned downtime by 30%.
  • Chemical Plant BMS: It connects flame detectors and gas sensors to Tricon V11, enabling <10ms response to combustion anomalies and meeting SIL 3 safety requirements.
  • Power Generation F&G: The TRICONEX 8310 integrates fire alarm contacts with turbine control systems, supporting hot-swappable maintenance to prevent forced outages.
  • Mining HIPPS: It monitors high-integrity pressure protection sensors, with optical isolation shielding against electrical noise in underground environments.

Comparisons with Competing Products

Feature TRICONEX 8310 Competitor A (Honeywell FSC DI Module) Competitor B (Emerson DeltaV SIS DI Module)
Redundancy 2oo3 TMR voting 1oo2 2oo3 (optional)
Response Time <10 ms 15–20 ms 10–15 ms
Hot-Swap Yes No Yes (partial)
Channel Count 32 16 32
Safety Certification IEC 61508 SIL 3 IEC 61508 SIL 3 IEC 61508 SIL 3
Tricon Integration Native (TriStation 1131) Manual mapping Gateway required

Selection Suggestions and Precautions

  • Selection Suggestions
    1. Choose the TRICONEX 8310 for Tricon V10/V11 SIS needing 32-channel DI with 2oo3 redundancy and SIL 3 compliance.
    2. Pair with redundant Tricon controllers for ESD/BMS/F&G systems requiring hot-swappable maintenance.
    3. Prioritize for applications needing <10ms response and on-line diagnostics to enhance safety and reduce downtime.
  • Precautions
    1. Use 24-125 VDC input to avoid damaging the TRICONEX 8310 or causing voting errors.
    2. Calibrate channels quarterly to maintain <10ms response and 2oo3 voting integrity.
    3. Follow ESD protocols during hot-swap to protect TMR circuitry and communication ports.
    4. For new projects, ensure compatibility with Tricon V10/V11 firmware; the TRICONEX 8310 is not compatible with Trident controllers.