The IS230TPROH2C is a high-performance communication interface terminal board manufactured by GE Energy (now part of Baker Hughes) as part of the Mark VIe series distributed control system. This termination board serves as the physical interface between field communication networks and the Mark VIe PROFINET communication modules, specifically designed for use with the IS220PPROH1A (PROFINET IO module). The IS230TPROH2C provides screw-clamp terminal connections for PROFINET network cables, integrated signal conditioning, shielding connections, and robust isolation for reliable industrial Ethernet communication. It is designed for PROFINET-based turbine control applications requiring high-speed, deterministic Ethernet communication for distributed control and real-time data exchange, making it an essential component for modern power plants and industrial automation systems.

Category:

Description

Product Parameters

Parameter Specification
Model IS230TPROH2C
Manufacturer GE Energy / Baker Hughes
Platform Mark VIe
Type Communication termination board (PROFINET)
Compatible Modules IS220PPROH1A (PROFINET IO module)
Ethernet Ports 2x (shielded RJ-45 via field wiring)
Terminal Type Screw-clamp (pluggable, 2‑piece)
Number of Positions 16 positions (field wiring side)
Wire Gauge 0.2–2.5 mm² (AWG 24–14)
Cable Type CAT5e or CAT6 shielded twisted pair
Shielding Connection Integrated shield termination points
Signal Conditioning Termination resistors, ESD protection (Level 3)
Isolation 1500 V (field‑to‑backplane via module)
LED Indicators None (status via communication module)
Operating Temperature -30°C to +70°C
Storage Temperature -40°C to +85°C
Humidity 5% to 95% (non‑condensing)
Dimensions Standard Mark VIe terminal board form factor
Weight Approx. 0.4 kg
MTBF > 200,000 hours

Advantages and Key Features

  • Dedicated PROFINET Termination – The IS230TPROH2C is specifically designed for PROFINET communication modules (IS220PPROH1A), providing reliable termination for industrial Ethernet networks used in turbine control applications.

  • Integrated Shield Termination – Provides dedicated shield termination points on the IS230TPROH2C, ensuring proper grounding of cable shields to minimize electromagnetic interference and maintain signal integrity in high‑EMI environments.

  • Pluggable Terminal Design – The IS230TPROH2C features a 2‑piece pluggable terminal block design, allowing field wiring to be disconnected without removing individual wires, simplifying maintenance and module replacement.

  • Dual Ethernet Support – Supports connection of two independent Ethernet cables for redundant network configurations, including Media Redundancy Protocol (MRP) ring topologies.

  • Enhanced ESD Protection – Level 3 ESD protection (IEC 61000‑4‑2) protects the IS230TPROH2C and connected communication modules from electrostatic discharge.

  • Wide Operating Temperature Range – Rated for -30°C to +70°C, suitable for outdoor and harsh turbine environments.

  • Flame‑Retardant Housing – UL 94 V‑0 rated material provides safety in the event of electrical faults.


Application Fields and Use Cases

1. PROFINET Network Termination

The IS230TPROH2C provides field wiring termination for PROFINET cables connecting the IS220PPROH1A to remote I/O stations, VFDs, smart instrumentation, and other PROFINET devices.

2. Redundant Ethernet Networks

Supports dual Ethernet connections for redundant network topologies (active‑active or active‑standby), ensuring uninterrupted communication during network failures.

3. Ring Topology (MRP)

The IS230TPROH2C enables Media Redundancy Protocol (MRP) ring configurations by providing wiring connections for both ring ports.

4. Remote I/O Integration

Provides PROFINET connections to remote I/O stations located near field instruments, reducing cabling costs.

5. VFD and Smart Instrumentation Integration

Connects PROFINET-capable VFDs, smart transmitters, and positioners to the Mark VIe control system.

6. Retrofit Projects

The IS230TPROH2C is used in Mark VIe upgrades from legacy systems to provide modern PROFINET communication capability.


Comparison with Competing Products

Feature IS230TPROH2C (GE) IS230TBTCH1B (GE) IS220PPROH1A (Direct) ABB TU830 Siemens 6ES7 392-1AJ00
Platform Mark VIe Mark VIe Mark VIe AC 800M S7-400
Type PROFINET termination Universal Module (no TB) Terminal unit Terminal block
PROFINET Support Dedicated Via module Direct Via module Direct
Shield Termination Yes No No Yes No
Cable Type CAT5e/CAT6 CAT5e/CAT6 CAT5e/CAT6 CAT5e/CAT6 CAT5e
ESD Protection Level 3 Level 3 Via module Level 3 Level 2
Temp Range -30°C to +70°C -40°C to +85°C -30°C to +65°C -25°C to +60°C 0°C to +60°C
Pluggable Yes Yes N/A Yes No
MTBF > 200,000 hrs > 200,000 hrs > 200,000 hrs > 120,000 hrs > 80,000 hrs

Key Differentiators: The IS230TPROH2C is a dedicated PROFINET termination board providing integrated shield termination and surge protection specifically designed for the IS220PPROH1A communication module. It offers enhanced protection against EMI and ESD in industrial environments. Unlike universal terminal boards (IS230TBTCH1B), the IS230TPROH2C is optimized for PROFINET applications with dedicated shielding connections. Compared to direct connections (without a termination board), the IS230TPROH2C provides significantly better noise immunity and maintenance convenience.


Selection Suggestions and Precautions

Selection Criteria

  • Choose the IS230TPROH2C for Mark VIe PROFINET applications requiring reliable field termination for the IS220PPROH1A communication module.

  • For applications using alternative communication protocols (PROFIBUS, Modbus TCP), use the appropriate termination board (IS230TPRFH2CIS230TMBTH2C).

  • Ensure proper network topology (line or ring) is supported by the IS230TPROH2C.

  • Verify the cable type (CAT5e or CAT6 shielded) is compatible.

Critical Precautions

  1. Shield Termination – Properly connect cable shields to the dedicated shield termination points on the IS230TPROH2C. Ground shields at the terminal board end for PROFINET networks, following GE recommended practices.

  2. Cable Quality – Use CAT5e or CAT6 shielded twisted‑pair cables with the IS230TPROH2C. Shielded cables are strongly recommended to prevent EMI interference in industrial environments.

  3. Cable Length – Maintain Ethernet cable length within PROFINET specifications (maximum 100 meters per segment). Use switches or repeaters for longer distances.

  4. Network Topology – The IS230TPROH2C supports line (daisy‑chain) and ring (MRP) topologies. For ring topology, enable MRP and configure the redundancy manager on one switch.

  5. Terminal Connections – Use proper wire stripping length (approximately 7–8 mm). Recommended torque: 0.5–0.6 N·m. Over‑tightening may damage terminals; under‑tightening may cause intermittent connections.

  6. ESD Handling – Use grounded wrist straps when handling the IS230TPROH2C to prevent static damage.

  7. IP Configuration – The IS230TPROH2C is a passive termination board; IP configuration is performed via the IS220PPROH1A module.

  8. MRP Configuration – For ring topologies, configure MRP properly to ensure fast recovery (< 200 ms) from network breaks.

  9. Obsolescence – The IS230TPROH2C is in active production with long‑term support. For future projects requiring additional features, evaluate the IS230TPROH2D when available. Keep spare boards for critical communication applications.

COMTROL 97590-8
Schneider 140CPS11420
ABB AI801
A-B 1747-SN