GE IS200TTPWH1A

¥999.00

IS200TTPWH1A is a Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for thermocouple and pressure transducer inputs with enhanced diagnostics and extended temperature range. This board provides centralized termination for thermocouple sensors (J, K, T, E, R, S, B) as well as 4–20 mA or voltage pressure transducer signals, combining temperature and pressure monitoring in a single board. The IS200TTPWH1A features integrated termination points with built-in signal conditioning including cold-junction compensation (CJC) for thermocouples, excitation for transducers, filtering, enhanced isolation, and diagnostics. It offers 16 mixed input channels (configurable as thermocouple or pressure transducer), with enhanced diagnostics and extended temperature range.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TTPWH1A
Total Channels 16 mixed inputs (configurable per channel)
Thermocouple Inputs Up to 16 channels (J, K, T, E, R, S, B)
Pressure Transducer Inputs Up to 16 channels (4–20 mA, 0–10 V, ±10 V selectable)
Thermocouple Range ±100 mV
Transducer Range 0–20 mA, 4–20 mA, 0–5 V, 0–10 V, ±10 V
Cold-Junction Compensation Dual redundant CJC sensors (accuracy ±0.3°C) — upgraded from ±0.5°C
ADC Resolution 24-bit delta-sigma (thermocouple), 16-bit SAR (transducer)
Sampling Rate 2–250 SPS (thermocouple), 10–500 SPS (transducer)
Accuracy (TC) ±0.05% of reading + ±0.5°C — upgraded from ±0.1% + ±1°C
Accuracy (Transducer) ±0.05% FS — upgraded from ±0.1% FS
Transducer Loop Power 24 VDC (externally supplied only)
Isolation 2000 VAC (field-to-system) — upgraded from 1500 VAC
CMRR >110 dB @ 50/60 Hz — upgraded from >100 dB
Diagnostics Open-circuit detection, short-circuit detection, dual CJC fault monitoring and auto-failover, over/under-range detection, loop power fault monitoring, reference validation
Status Indication 16 green LEDs (channel active), 2 red LEDs (diagnostic fault summary), 1 yellow LED (reference/calibration status), 1 blue LED (CJC redundancy active)
Operating Temperature –40°C to +70°C — upgraded from –30°C to +65°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • Mixed Input FlexibilityIS200TTPWH1A combines thermocouple and pressure transducer inputs on a single board, eliminating the need for separate terminal boards for temperature and pressure monitoring.

  • Configurable Channel Allocation: Each channel can be independently configured as thermocouple or pressure transducer via GE ToolboxST.

  • Superior Accuracy: TC: ±0.05% + ±0.5°C; Transducer: ±0.05% FS provides high measurement precision.

  • Dual-Redundant CJC: Two independent cold-junction sensors with automatic cross-validation and failover ensure uninterrupted thermocouple measurement accuracy.

  • Extended Temperature Range: –40°C to +70°C operation makes IS200TTPWH1A suitable for extreme environments.

  • Enhanced Isolation: 2000 VAC isolation and >110 dB CMRR provide superior protection.

  • 24-Bit Thermocouple Conversion: High-resolution ADC delivers stable, noise-free temperature readings.

  • Programmable Transducer Inputs: Supports 4–20 mA, 0–10 V, or ±10 V inputs.

  • Comprehensive Diagnostics: Open-circuit, short-circuit, dual CJC auto-failover, over/under-range, loop power fault, and reference validation per channel.

  • ToolboxST Integration: Full configuration, calibration, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for IS200TTPWG1B and earlier mixed thermocouple/transducer terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Exhaust gas temperature (thermocouple) combined with fuel gas pressure (4–20 mA), steam pressure (4–20 mA), and bearing temperature (thermocouple).

  • Combined Cycle Plants: HRSG superheater temperature (thermocouple) plus steam drum pressure (4–20 mA) and feedwater flow (4–20 mA).

  • Compressor Stations: Discharge temperature (thermocouple) combined with suction/discharge pressure (4–20 mA).

  • Aeroderivative Turbines: Exhaust temperature (thermocouple) plus fuel flow (4–20 mA) and oil pressure (4–20 mA).

  • Arctic & Desert Installations: Extreme-environment monitoring applications.

Comparison with Competing Products

Feature GE IS200TTPWH1A GE IS200TTPWG1B Competitor A (Mixed TC/Transducer) Competitor B (Separate TC + Transducer)
Total Inputs 16 mixed 16 mixed 8 mixed 16 (8 + 8)
CJC Accuracy ±0.3°C (dual redundant) ±0.5°C (single) ±1.2°C ±0.5°C
CJC Redundancy Yes (auto-failover) No No No
TC Accuracy ±0.05% + ±0.5°C ±0.1% + ±1°C ±0.2% + ±2°C ±0.1% + ±1°C
Transducer Accuracy ±0.05% FS ±0.1% FS ±0.2% FS ±0.1% FS
Isolation 2000 VAC 1500 VAC 1000 VAC 1500 VAC
Operating Temp –40°C to +70°C –30°C to +65°C 0°C to 50°C –30°C to +65°C
Reference Validation Yes No No No

Key AdvantageIS200TTPWH1A provides 16 mixed thermocouple/transducer inputs with dual-redundant CJC (±0.3°C), superior accuracy, extended –40°C to +70°C temperature range, 2000 VAC isolation, and comprehensive diagnostics including reference validation—making it ideal for turbine applications requiring both temperature and pressure monitoring in extreme environments.

Selection Guidelines & Recommendations

  • Channel Configuration: Determine required mix—configure each channel in GE ToolboxST.

  • Thermocouple Type: Select J, K, T, E, R, S, or B per channel.

  • Transducer Type: Configure 4–20 mA, 0–10 V, or ±10 V per channel.

  • Dual CJC Sensors: Automatic failover—blue LED indicates redundancy is active.

  • Transducer Loop Power: External 24 VDC supplies required.

  • Controller Firmware: Requires Mark VIe processor firmware v8.5 or later.

  • Wiring Guidelines: Use shielded thermocouple extension-grade leads and twisted-pair cables.

  • Spare Strategy: Keep one spare per turbine; lead times 8–12 weeks.

  • Retrofit: Direct replacement for IS200TTPWG1B—regenerate configuration in GE ToolboxST.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Thermocouple Polarity: Reverse connection produces negative readings.

  3. Transducer Polarity: Observe correct polarity for 4–20 mA loops and voltage inputs.

  4. CJC Protection: Do not apply conformal coating or tape over the terminal block area.

  5. Transducer Loop Power: External 24 VDC required.

  6. Grounding: Connect AGND to Mark VIe system ground at single star point.

  7. Shield Termination: Ground shields only at cabinet end.

  8. ESD Handling: Use grounded wrist straps; field repair not possible.

  9. Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.

  10. Reference Validation: Yellow LED indicates reference drift—schedule factory recalibration if illuminated.

  11. CJC Redundancy Status: Blue LED flashing indicates one CJC sensor failed—schedule service.

  12. Channel Mapping: With 16 mixed channels, verify field wiring maps to correct ToolboxST assignments.

Ӹ NCN25-F35-A2-250-15M-V1
A-B 1756-DNB/D
EPRO UES815S-24A
A-B 1756-A17