GE IS200TRPAH1A

¥999.00

IS200TRPAH1A is a Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for transducer power supply and signal conditioning in turbine control applications. This board provides centralized termination for powering and monitoring field-mounted transducers such as pressure transmitters, temperature transmitters, position transducers, and other 2-wire or 4-wire sensors, connecting to the Mark VIe main VME-based controller processors via front-panel I/O cables. The IS200TRPAH1A features integrated termination points for transducer power supply with built-in voltage regulation, filtering, isolation, and diagnostics. It offers 16 isolated transducer power channels with adjustable voltage output and comprehensive diagnostics.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TRPAH1A
Transducer Power Channels 16 isolated channels
Output Voltage 24 VDC (regulated, programmable per channel)
Output Current 50 mA per channel (800 mA total maximum)
Input Voltage Range 24/48/125 VDC (auto-ranging, from Mark VIe rack)
Voltage Regulation ±0.1%
Ripple/Noise < 10 mV peak-to-peak
Isolation 1500 VAC (channel-to-channel and field-to-system)
Diagnostics Overcurrent detection, short-circuit detection, under/over-voltage monitoring, open-circuit detection
Status Indication 16 green LEDs (channel active), 16 red LEDs (channel fault), 2 red summary fault LEDs
Operating Temperature –30°C to +65°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • High Channel Density: 16 isolated transducer power channels in a single VME slot—double the density of competing modules.

  • Programmable Output Voltage: Per-channel adjustable 24 VDC output via GE ToolboxST, accommodating different transducer requirements.

  • High Accuracy Regulation: ±0.1% voltage regulation ensures stable transducer operation.

  • Comprehensive Diagnostics: Overcurrent, short-circuit, under/over-voltage, and open-circuit detection per channel enable predictive maintenance.

  • Low Ripple/Noise: < 10 mV peak-to-peak ripple ensures clean power for sensitive transducers.

  • Opto-Isolation: 1500 VAC isolation protects the Mark VIe backplane from field wiring faults.

  • ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for earlier GE transducer power terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Powering pressure transmitters for fuel gas, lube oil, cooling water; temperature transmitters; position transducers for control valves.

  • Combined Cycle Plants: Powering HRSG pressure and temperature transmitters.

  • Compressor Stations: Powering suction/discharge pressure transmitters and temperature transmitters.

  • Aeroderivative Turbines: Powering fuel flow, oil pressure, and temperature transmitters.

  • General Industrial: Powering 2-wire and 4-wire field transducers.

Comparison with Competing Products

Feature GE IS200TRPAH1A Competitor A (Transducer Power Module) Competitor B (Power Supply Module)
Power Channels 16 isolated 8 isolated 8 non-isolated
Output Voltage 24 VDC (programmable) 24 VDC (fixed) 24 VDC (fixed)
Output Current 50 mA/channel 40 mA/channel 50 mA/channel
Voltage Regulation ±0.1% ±1% ±0.5%
Diagnostics Overcurrent, short, under/over-voltage, open Overcurrent only Overcurrent only
Isolation 1500 VAC 1000 VAC 500 VDC
Operating Temp –30°C to +65°C 0°C to 50°C 0°C to 60°C

Key AdvantageIS200TRPAH1A provides 16 isolated transducer power channels—double the density of competing modules—with programmable 24 VDC output, high accuracy regulation (±0.1%), and comprehensive diagnostics, making it ideal for powering field transducers in turbine applications.

Selection Guidelines & Recommendations

  • Channel Count: Determine number of transducers requiring power—up to 16 per board.

  • Output Voltage: Configure per-channel output voltage (default 24 VDC) in GE ToolboxST if different from standard.

  • Current Requirements: Verify each transducer’s current draw does not exceed 50 mA per channel.

  • Diagnostic Configuration: Enable overcurrent, short-circuit, and under/over-voltage monitoring for critical transducers.

  • Controller Firmware: Requires Mark VIe processor firmware v7.5 or later.

  • Wiring Guidelines: Use shielded twisted-pair cables for transducer connections. Maintain shield grounding only at the Mark VIe cabinet end.

  • Spare Strategy: Keep one spare per turbine; lead times 6–8 weeks.

  • Retrofit: Direct replacement—regenerate configuration in GE ToolboxST.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Power Polarity: Observe correct polarity for transducer connections—reverse polarity may damage field devices.

  3. Current Limit: Do not exceed 50 mA per channel—overcurrent protection will trip and latch.

  4. Short-Circuit: If a short is detected, the channel will latch off. Clear the fault and reset via GE ToolboxST.

  5. Grounding: Connect AGND to Mark VIe system ground at single star point.

  6. Shield Termination: Ground transducer cable shields only at cabinet end.

  7. ESD Handling: Use grounded wrist straps; field repair not possible.

  8. Voltage Verification: Verify transducer voltage requirements before powering up.

  9. Channel Mapping: With 16 channels, verify field wiring maps to correct ToolboxST channel numbers.

YOKOGAWA UD1CG3-004N-1AA-2SA-N/CN
SCHNEIDER 140CRA93100
YASKAWA SGDV-200A01A002000
A-B 1756-IF16