Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200JPDSG1A |
| Pulse Inputs | 4–8 pulse inputs (J-type, speed, flow, position sensors) |
| Data Synchronization | Time alignment, phase synchronization, coordinated data acquisition |
| J-Type Gateway Functions | Data routing, protocol conversion, gateway communication |
| Supported Protocols | Modbus RTU, GE pulse protocols, J-type protocols |
| Communication | J-type serial interfaces, highway integration |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated J-Gateway Pulse Data Synchronization: The IS200JPDSG1A provides specialized pulse data synchronization and J-type gateway communication.
Data Synchronization: The IS200JPDSG1A handles time alignment and phase synchronization.
J-Type Gateway Functions: Enables data routing and protocol conversion.
Application Fields and Case Studies
Used in pulse data synchronization applications, J-type network integration requiring coordinated data acquisition, and gateway communication for synchronized pulse data. In a 600 MW plant, the IS200JPDSG1A provided reliable pulse data synchronization and gateway communication.
Comparison with Competing Products
| Dimension | IS200JPDSG1A | IS200JPDPG1A | IS200JPDMG1ADC |
|---|---|---|---|
| Primary Function | Pulse data synchronization | Pulse data protection | Pulse data management |
| Synchronization | Yes | No | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200JPDSG1A for pulse data synchronization and J-type gateway applications. Verify compatibility with your specific pulse sensors and synchronization requirements. Deploy for time-critical pulse data applications.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and pulse connections. Confirm compatibility with your specific pulse sensors and synchronization requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all synchronization and gateway functions during commissioning. The IS200JPDSG1A is critical for pulse data synchronization – ensure all settings are verified before placing in service. Ensure proper shielding for pulse signals to avoid noise interference. Regular verification of pulse data quality and synchronization accuracy is recommended. Ensure communication cabling does not exceed maximum recommended length.