Description
Parameters
-
Analog Inputs: 4 channels, 4–20mA (default) or 0–10V DC (jumper-configurable)
-
Analog Outputs: 4 channels, 4–20mA (default) or 0–10V DC (jumper-configurable)
-
Resolution: 12-bit ADC (inputs) / 12-bit DAC (outputs)
-
Accuracy: ±0.1% of full scale (inputs and outputs)
-
Input Impedance: 250Ω (current) / >1MΩ (voltage)
-
Output Drive: 4–20mA into 750Ω max / 0–10V into 5kΩ min
-
Isolation: 1500V RMS optical isolation (channel-to-backplane)
-
Power: +5V DC @ 1.0A, +15V DC @ 0.3A (requires both rails)
-
Scan/Update Rate: 100ms (inputs) / 100ms (outputs)
-
Coating: Basic conformal coating (suffix A) – single-layer acrylic
-
Temp Range: 0°C to +60°C
-
Mounting: 6U VME Eurocard, single-slot
-
Diagnostics: LED status per channel (input over-range/under-range, output fault/open-circuit)
Advantages & Features
-
Hybrid I/O capability – 4 analog inputs + 4 analog outputs on a single board, saving cabinet space and reducing overall board count
-
Versatile signal support – inputs and outputs independently configurable for 4–20mA or 0–10V, compatible with most industrial transmitters and actuators
-
Isolated channels reduce ground loop interference and protect the backplane from field wiring faults
-
Simple configuration – signal type selected via jumpers (no complex software setup)
-
Basic A-grade coating provides light moisture and dust protection for indoor installations
-
Front-panel LEDs for per-channel status (input over-range/under-range, output fault/open-circuit)
-
Compatible with Mark IV backplanes and some VIe systems (with adapter)
Application Cases
-
Turbine inlet guide vane (IGV) position control – reading 4–20mA position feedback and outputting 4–20mA to positioner/actuator
-
Fuel gas pressure control – reading pressure transmitter and outputting to control valve positioner
-
Steam pressure and flow control – reading transmitters and outputting to throttle or extraction valve positioners
-
Lube oil pressure and temperature control – reading sensors and outputting to cooling water or bypass valves
-
Retrofit projects replacing separate input and output boards with a single hybrid solution
Competitor Comparison
-
vs. DS3800HIMA (input-only): HIOA offers outputs in addition to inputs, but fewer total channels (4 in/4 out vs. 8 differential inputs on HIMA)
-
vs. DS3800HOMB (output-only): HIOA offers inputs and outputs in a single board, reducing board count vs. separate HIMA + HOMB
-
vs. DS3800HSCB (high-speed analog): HIOA is standard speed (100ms), HSCB offers faster scanning for dynamic signals
-
vs. ABB TB711 : ABB offers higher resolution (14-bit) and PROFIBUS/Modbus communication, but lacks hybrid I/O on a single board
-
vs. Siemens 7MH410 : Siemens offers HART protocol support on some variants, but GE HIOA offers hybrid I/O in one slot
-
vs. Woodward 8440-2015 : Woodward offers more flexible configuration software, but GE HIOA provides a compact hybrid solution
-
vs. Honeywell 51304638 : Honeywell offers better long-term stability (±0.05%), but GE HIOA combines inputs and outputs
Selection Suggestions
-
Critical: Confirm input and output signal types (4–20mA or 0–10V) before installation – jumpers must match your transmitters and actuators
-
Verify your backplane provides both +5V and +15V – this board requires both rails
-
Assess channel count – 4 inputs and 4 outputs are suitable for small to medium control loops; for larger applications, consider multiple boards or separate HIMA/HOMB boards
-
Determine accuracy requirement – 0.1% is sufficient for most turbine control loops
-
Evaluate environmental conditions – A coating is suitable for clean, dry indoor installations; upgrade to B/C/D/G/H if needed
-
Order mating front connector (p/n may vary – confirm with GE)
-
For critical applications, consider used/refurbished units with 90-day warranty
Precautions
-
Critical: Do not exceed 30mA or ±30V on input channels – overvoltage may damage the ADC and isolation circuits
-
Critical: Do not short-circuit output channels – outputs are protected but prolonged shorts may cause damage
-
Critical: Use shielded twisted-pair cables for all analog inputs and outputs to avoid EMI – especially near VFDs or large transformers
-
Ensure field power supply (+24V DC) for loop-powered transmitters is stable (if used)
-
Basic A coating does not protect against humidity or corrosive gases – upgrade to B/C/D/G/H if your environment has moisture or chemicals
-
Allow 30-minute warm-up before calibration
-
Store in ESD-safe packaging – edge connector is static-sensitive
-
Periodically verify input and output calibration every 2 years against a certified reference
-
Do not hot-swap – Mark IV backplanes require power-off for insertion/removal
-
If replacing separate input and output boards, verify wiring and pinout compatibility – HIOA may differ from HIMA/HOMB series in pin assignments

SIEMENS 6ES7214-2AD23-0XB8
A-B 1756-OW16I
A-B 22B-D010N104
A-B 1746-IM16