GE IS200EISBH1AAB

¥999.00

The IS200EISBH1AAB is an Enhanced I/O Scanner / Bus Highway Interface (EISBH) Board from General Electric’s Mark VI Speedtronic™ series. This model shares the core I/O scanning and bus highway functionality of the IS200EISBH1AAA but features a distinct suffix configuration (“AAB”), indicating a different firmware preload, I/O scanning protocol variant, or specific configuration tailored for alternative I/O module families, scanning priorities, or bus highway architectures. The IS200EISBH1AAB serves as a dedicated high-speed scanner and bus interface for distributed I/O systems, remote terminal units (RTUs), and highway communication networks, handling large numbers of I/O points across distributed systems. The “EISBH” designation indicates “Enhanced I/O Scanner / Bus Highway.” The “1” series indicates standard processing capability. The “AAB” suffix typically signifies a specific firmware version optimized for different I/O module families, specific bus highway timing requirements, or particular scanning priorities such as higher priority for critical analog loops or faster digital event capture. The board mounts directly into a Mark VI VME backplane and provides high-speed, deterministic data exchange between the main DSP processor and distributed I/O networks.

Category:

Description

Technical Specifications

Parameter Specification
Manufacturer General Electric
Model IS200EISBH1AAB
Series Mark VI / Speedtronic™
Board Type Enhanced I/O Scanner / Bus Highway Interface
I/O Scanning Channels Supports up to 1024 digital I/O points and 256 analog I/O points (depending on configuration)
Communication Interfaces 2× bus highway ports (GE proprietary bus protocol)
Supported Protocols GE proprietary bus highway protocol (variant-specific), Modbus RTU
Data Transfer Rate Up to 10 Mbps (depending on configuration)
Scanning Rate Configurable scan rates (10 ms to 500 ms typical, variant-dependent)
Onboard Processing Standard processor with I/O scanning and bus interface firmware (AAB variant)
I/O Support Digital inputs/outputs, analog inputs/outputs, thermocouple inputs, RTD inputs
Communication Modes Master/Slave, Scanner/Remote I/O
Distributed I/O Support Remote I/O racks, distributed terminal boards, expansion chassis
Backplane Interface VME bus (P1/P2 connectors)
Power Requirements +5V DC / 2.5A, ±15V DC / 0.5A
Operating Temperature -30°C to +65°C
Storage Temperature -40°C to +85°C
MTBF > 110,000 hours
Suffix Meaning “AAB” = specific firmware/application configuration for different I/O module families or scanning priorities

Advantages and Key Features

Dedicated I/O Scanning with Variant-Specific Firmware: The IS200EISBH1AAB provides dedicated, high-speed scanning and data acquisition from distributed I/O systems, with the “AAB” firmware variant specifically configured for compatibility with certain I/O module families, scanning priorities, or bus highway architectures.

Configurable Scanning with Priority Optimization: The “AAB” firmware on the IS200EISBH1AAB includes pre-configured scanning priorities, optimizing for faster critical analog loop scanning or digital event capture, reducing commissioning time.

High I/O Capacity: Supports up to 1024 digital and 256 analog I/O points, making it suitable for complex turbine installations with extensive I/O requirements.

Flexible I/O Module Support: The IS200EISBH1AAB supports different I/O module families than the IS200EISBH1AAA, allowing system designers to select the correct scanner for their specific I/O hardware.

Comprehensive Diagnostics: Onboard diagnostics include bus communication status, I/O point health monitoring, scanning error counting, and fault reporting.

Application Fields and Case Studies

The IS200EISBH1AAB is used in GE gas and steam turbine installations with specific I/O module families requiring variant-specific scanning, combined-cycle plants requiring optimized scanning priorities for critical control loops, and facilities with specific bus highway architectures. In a 500 MW combined-cycle plant, the IS200EISBH1AAB was deployed to scan and manage over 600 I/O points with specific module types that required the “AAB” firmware for correct communication timing and priority. The board’s optimized scanning priorities ensured that critical analog loops were scanned at 10 ms intervals while slower monitoring points were scanned at 100 ms intervals, optimizing system performance. The “AAB” firmware on the IS200EISBH1AAB was pre-configured for the site’s specific I/O module families, reducing commissioning time by 2 days.

Comparison with Competing Products

Dimension IS200EISBH1AAB IS200EISBH1AAA IS200EBRGH2ABA Generic I/O Scanner
Primary Function I/O scanner/bus highway I/O scanner/bus highway Remote I/O gateway Non-native
Firmware Variant AAB (specific modules) AAA (different modules) GE remote I/O Various
I/O Module Support Specific module families Different module families Limited Varies
Scanning Priorities Optimized (specific) Standard Fixed Varies
VME Integration Direct (Mark VI native) Direct (Mark VI native) Direct (Mark VI native) External
Diagnostics Comprehensive + variant-specific Comprehensive + variant-specific Comprehensive + node-specific Basic

The IS200EISBH1AAB offers the same hardware capabilities as the IS200EISBH1AAA but with different firmware optimization for specific I/O module families or scanning priorities. The “AAB” variant is preferred when your I/O hardware requires that specific firmware version.

Selection Recommendations

Choose the IS200EISBH1AAB when your Mark VI installation requires I/O scanning with specific I/O module families that require the “AAB” firmware variant. Select it over the IS200EISBH1AAA when compatibility with specific I/O hardware or optimized scanning priorities is required. Deploy redundant IS200EISBH1AAB boards for critical I/O scanning paths. Verify that your I/O modules are compatible with the “AAB” firmware before commissioning. Consult GE documentation to confirm which suffix variant is recommended for your specific I/O equipment.

Precautions and Important Notes

Always use ESD-safe handling procedures when installing the IS200EISBH1AAB. Verify bus highway cable quality and termination. Configure with correct scanning rates, addressing, and I/O configurations. Verify that the preloaded “AAB” firmware supports your specific I/O modules before commissioning. Never interrupt firmware updates. The IS200EISBH1AAB draws 2.5A (+5V) – verify rack power supply capacity. Document all I/O configurations and scanning settings before board replacement. Store spare boards in anti-static packaging and rotate inventory every 24 months. Do not mix IS200EISBH1AAB with IS200EISBH1AAA in redundant pairs without verifying identical firmware. Consult GE engineering when integrating the IS200EISBH1AAB with non-standard I/O architectures. Allow the IS200EISBH1AAB to complete its boot sequence (approximately 30 seconds) before relying on I/O data. Verify that bus highway cabling does not exceed maximum recommended length. Ensure all remote I/O racks are properly terminated and addressed. If replacing an IS200EISBH1AAA with an IS200EISBH1AAB, verify that all I/O modules are compatible with the new firmware before installation. Thoroughly test all I/O points after replacement to ensure correct scanning and data integrity.

WESTINGHOUSE 1B30035H01
GE 12HFA51A42H
GE IC200ALG326
WESTINGHOUSE 1C31224G01

Reviews

There are no reviews yet.

Be the first to review “GE IS200EISBH1AAB”

Your email address will not be published. Required fields are marked *

Post comment