Description
Parameters
| Parameter | Specification |
|---|---|
| Input Channels | 16, differential (isolated) |
| Input Ranges | ±10V, 0–20mA, 4–20mA (software selectable per channel) |
| Overload Protection | ±30V continuous (voltage); ±50mA (current) |
| ADC Resolution | 16-bit SAR (successive approximation) |
| Accuracy | ±0.1% FS at 25°C; ±0.25% over -40°C to +70°C |
| Input Impedance | >1MΩ (voltage mode); 250Ω (current mode) |
| Filtering | Programmable low-pass: 10Hz, 50Hz, 100Hz, 500Hz |
| Sample Rate | 10Hz–500Hz (software selectable) |
| CMRR | >90dB at 50/60Hz |
| Diagnostics | Over-range, under-range, open-wire detection, reference voltage monitor |
| Isolation | 1500Vrms (input-to-backplane); 500VDC (channel-to-channel) |
| Power Supply | 5VDC (backplane), 300mA; 24VDC aux, 100mA |
| Operating Temp | -40°C to +70°C |
| Mounting | 6U VME Eurocard, 160mm depth |
| Certifications | UL, CSA, ATEX Zone 2, SIL 1 capable |
Advantages & Features
-
High Channel Density – The GE DS4820A1SA provides 16 analog inputs in a single slot, reducing rack space and simplifying wiring for large I/O count applications.
-
Versatile Input Ranges – Each channel on the GE DS4820A1SA can be independently configured for voltage or current signals, accommodating mixed sensor types without additional modules.
-
Programmable Filtering – Selectable filters (10Hz–500Hz) allow the GE DS4820A1SA to reject noise while maintaining fast response for turbine control loops.
-
Comprehensive Diagnostics – Continuous open-wire, over-range, and under-range detection ensure signal integrity; faults are reported to the controller within one scan cycle.
-
High Common-Mode Rejection – >90dB CMRR ensures the GE DS4820A1SA rejects noise from nearby power cables in electrically noisy environments.
-
Cost-Effective – The GE DS4820A1SA provides standard accuracy (16-bit) at a lower cost than high-precision 24-bit variants, ideal for non-critical monitoring applications.
Application Cases
-
Turbine Pressure Monitoring – The GE DS4820A1SA monitors 16 pressure transmitters (4–20mA) on a gas turbine, providing data for fuel control and performance monitoring.
-
Flow Measurement – In a combined-cycle plant, the GE DS4820A1SA reads 16 flow meter signals (4–20mA) for water, steam, and fuel flow monitoring.
-
Level Monitoring – The GE DS4820A1SA monitors 16 level transmitters in a water treatment system, providing data for pump control and alarm annunciation.
-
Temperature Transmitter Inputs – The GE DS4820A1SA reads 16 temperature transmitter signals (4–20mA) for HRSG and auxiliary system monitoring.
Competitor Comparison
| Feature | GE DS4820A1SA | Siemens 6ES7331-7KF02 | ABB AI810 | Rockwell 1756-IF16 |
|---|---|---|---|---|
| Input Channels | 16 | 8 | 8 | 16 |
| Resolution | 16-bit | 16-bit | 14-bit | 16-bit |
| Input Ranges | ±10V, 0–20mA, 4–20mA | ±10V, 0–20mA, 4–20mA | ±10V, 0–20mA, 4–20mA | ±10V, 0–20mA, 4–20mA |
| Accuracy | ±0.1% | ±0.1% | ±0.15% | ±0.1% |
| Filtering | 10Hz–500Hz | 10Hz–500Hz | 10Hz–100Hz | 10Hz–100Hz |
| Open-wire Detection | Yes | Yes | Yes | Yes |
| SIL Rating | SIL 1 | SIL 1 | SIL 2 | SIL 1 |
| Relative Cost | Low-Med | Med | Med | Med-High |
The GE DS4820A1SA offers the highest channel density (16 channels) at a competitive cost, matching or exceeding the accuracy of Siemens and Rockwell modules.
Selection Suggestions
-
Choose the GE DS4820A1SA for standard accuracy analog input monitoring (pressure, flow, level, temperature via transmitters) requiring 16 channels per slot.
-
If your application requires higher accuracy (±0.05%) or 24-bit resolution, consider the DS3860 series modules.
-
For current loop signals (4–20mA), the GE DS4820A1SA provides a built-in 250Ω shunt resistor. Ensure the transmitter can drive the load (typically 24V DC supply is sufficient).
-
For SIL 2 applications, the GE DS4820A1SA is not rated SIL 2 — use DS3860 series modules instead.
-
Pair with matching terminal block TB500-A1 (with screw-clamp terminations for analog signals).
Precautions
-
Input Selection – Configure each channel for voltage or current mode via software. For current signals, the module automatically connects the 250Ω shunt. For voltage signals, ensure the input impedance remains >1MΩ.
-
Open-Wire Detection – The GE DS4820A1SA detects open-wire by injecting a small test current. For 4–20mA loops, this works reliably. For voltage signals, open-wire detection may cause slight loading — disable it for high-impedance sensors.
-
Grounding – Use differential inputs to reject ground loop noise. Connect signal commons to the module negative input if required. Avoid floating inputs.
-
Cable Shielding – Use shielded twisted-pair cables for analog signals. Connect shields to the GE DS4820A1SA common terminal at the module end only. Avoid routing near high-power cables.
-
Filter Selection – For high-noise environments (VFDs, motor feeders), select the 10Hz or 50Hz filter. For fast-changing signals (pressure transients), use 500Hz filter.
-
Calibration – Factory calibration is valid for 24 months. For ISO 17025 compliance, recalibrate using a precision voltage/current source (0.01% accuracy) following GE service procedure.
-
Power Supply – The GE DS4820A1SA draws 300mA from 5V plus 100mA from 24V aux. Ensure the power supply module has sufficient capacity.
-
ESD Handling – Use ESD-safe practices when handling the GE DS4820A1SA. The front-panel connector and ADC inputs are sensitive to electrostatic discharge.

A-B 1756-BA1
A-B 1747CPUԿ
TRICONEX 8609-396-7113755