The DS3820AISA is an 8-channel analog input with simultaneous sampling capability, designed for applications requiring phase-accurate or time-coherent measurements across multiple channels. It features 16-bit resolution, per-channel software-configurable input ranges (4–20 mA, 0–10 V, ±10 V), 1500 V isolation, and a dedicated sample-and-hold circuit per channel to capture all inputs at the exact same instant. The DS3820AISA is the solution for dynamic process monitoring and power quality analysis.

Category:

Description

Key Parameters

  • Channels: 8 differential, individually configurable

  • Inputs: 4–20 mA, 0–20 mA, 0–5 V, 0–10 V, ±10 V (software-selectable per channel)

  • Sampling Mode: Simultaneous (all channels sampled at same instant)

  • Resolution: 16-bit ADC

  • Sampling Rate: Up to 1 kHz per channel (simultaneous, global)

  • Accuracy: ±0.1% FS (25°C); ±0.3% over –40°C to +70°C

  • Phase Mismatch: < 0.1° at 50/60 Hz (between channels)

  • Isolation: 1500 V RMS field-to-logic (group isolated)

  • Power: 24 V DC, ≤6 W

  • Diagnostics: Open-circuit, over/under-range, watchdog timer

  • CMRR: >100 dB


Advantages

  • Simultaneous sampling – captures all 8 channels at precisely the same moment; eliminates phase errors between signals.

  • Software configurable per channel – each channel independently set for current or voltage.

  • High-speed sampling – up to 1 kHz per channel, suitable for dynamic process monitoring.

  • Hot-swappable – replace without rack power-down.

  • Minimal phase mismatch – < 0.1° at 50/60 Hz ensures accurate power and vector calculations.

  • Built-in diagnostics – alerts for broken wires and out-of-range conditions.


Applications

  • Power monitoring – 3-phase voltage and current measurements for power quality analysis (V, A, W, VAR, PF)

  • Motor control – simultaneous current and voltage monitoring for torque and efficiency calculations

  • Vibration analysis – multi-axis accelerometer data capture for predictive maintenance

  • Hydraulic systems – pressure and flow monitoring requiring time-correlated data

  • Test & measurement – dynamic process characterization and transient recording

  • Renewable energy – solar inverter and wind turbine output monitoring


Competitor Comparison

Feature DS3820AISA Standard Analog AI (Sequential) Competitor Simultaneous AI
Sampling Mode Simultaneous Sequential (per channel) Simultaneous
Phase Mismatch < 0.1° Up to 5° (at 60 Hz) < 0.2°
Max Sampling Rate 1 kHz/ch 250 Hz/ch 1 kHz/ch
Config Software per-channel Software/Jumper Software
Isolation Group Group Per-channel (premium)
Cost Mid-high Mid High

The DS3820AISA provides premium simultaneous sampling performance at a fraction of the cost of per-channel isolated competitors. Compared to standard sequential-scan modules, the DS3820AISA eliminates the phase delay that can cause significant errors in power calculations and dynamic control loops – errors that often go undetected until system instability occurs. For applications requiring precise time-correlation, the DS3820AISA is the clear choice over sequentially scanned alternatives. Against competitor simultaneous modules, the DS3820AISA offers comparable performance at a lower price point, making it the best value for power quality and dynamic monitoring applications.


Selection Tips

  • Choose DS3820AISA when you need time-coherent measurements across multiple channels – essential for power, vibration, and dynamic process control.

  • Ideal for 3-phase power systems (use 3 channels for voltage, 3 for current, 2 spare).

  • Verify your CPU scan rate can handle the 1 kHz data throughput.

  • Not suitable for applications where per-channel isolation is mandatory – consider the DS3820AIQA family instead.

  • If your application only requires static process monitoring (slow temperature/pressure), a standard sequential AI module will be more cost-effective.


Precautions

  • Wiring: Use shielded twisted-pair cables to maintain signal integrity at higher sampling rates.

  • Grounding: Maintain single-point grounding to avoid noise at high frequencies.

  • Power sequencing: Apply backplane power before field power.

  • Cooling: Ensure adequate airflow in dense racks – the DS3820AISA dissipates up to 6 W.

  • Data throughput: High sampling rates generate significant data traffic – ensure your controller and communication bus have sufficient bandwidth.

  • Spare: Keep one spare DS3820AISA for critical monitoring loops to minimize downtime.

  • Configuration: Set all channel input types before enabling simultaneous mode – changing a channel type may disrupt sampling timing.