GE DS3800XJBC1A1A

¥999.00

The DS3800XJBC1A1A is a high-reliability, extended serial communication and gateway board for the GE Mark IV turbine control system, featuring the latest firmware revision (1A1A) . It provides 4 independent serial ports with enhanced protocol supporthigher baud rates (up to 921.6 kbps) , improved diagnostics, and a ruggedized design for demanding applications. This board enables the Mark IV turbine controller to interface with multiple external systems such as DCS, SCADA, HMIs, and plant historians, with enhanced features for reliable operation in critical environments. It works alongside boards like the DS3800NVIA1G1CDS3800NVIA1G1DDS3800SCG, and DS3800TIMC.

Category:

Description

Key Parameters

  • Communication Ports: 4 independent serial ports

  • Protocols Supported: Modbus RTU (Master/Slave), GE Mark IV proprietary protocol, DNP3IEC 60870-5-101, ASCII, and user-configurable serial protocols

  • Physical Interfaces: RS-232, RS-422, RS-485 (per-port jumper-selectable)

  • Baud Rates: 300 to 921.6 kbps (software-selectable – enhanced)

  • Data Formats: 7 or 8 data bits, 1 or 2 stop bits, parity (none, even, odd)

  • Network Functionality: Acts as a gateway between the VME backplane and multiple external serial networks

  • Diagnostics: Per-port LED status (TX/RX/error), communication error counters, signal quality monitoringself-test on power-upenhanced fault logging (firmware 1A1A)

  • Isolation: 2500V RMS port-to-backplane

  • Temp Range: –40°C to +85°C (extended)

  • Power Supply: +5V (logic) from backplane (higher current draw due to advanced features)

  • Physical: 6U VME single-slot board

  • Key Features: 4 serial ports, enhanced protocol support (DNP3, IEC 60870-5-101), 921.6 kbps max baud, 2500V isolation, extended temp range, ruggedized design, enhanced diagnostics, firmware rev 1A1A


Advantages

  • High-speed communication – the DS3800XJBC1A1A supports baud rates up to 921.6 kbps, enabling faster data exchange with modern DCS and SCADA systems.

  • Extended protocol support – supports DNP3 and IEC 60870-5-101 in addition to Modbus RTU and GE proprietary protocols, making it ideal for utilities and transmission applications.

  • Ruggedized design – built with higher-grade components and conformal coating for enhanced reliability in harsh industrial environments.

  • Extended communication capacity – 4 serial ports allow connection to multiple external systems simultaneously.

  • Enhanced diagnostics – the 1A1A firmware provides improved fault logging and diagnostic reporting compared to earlier revisions, aiding predictive maintenance.

  • Superior isolation – 2500V RMS isolation protects the backplane from field-side surges and transients.

  • Extended temperature range – operates from –40°C to +85°C for harsh environments.

  • Drop-in compatible – works with all Mark IV backplanes and processor configurations.


Applications

  • Utility and transmission applications – the General Electric DS3800XJBC1A1A supports DNP3 and IEC 60870-5-101 protocols commonly used by electrical utilities for SCADA and grid communication.

  • Large combined-cycle plants – connects the Mark IV turbine controller to DCS, multiple HMIs, plant historians, and remote monitoring systems.

  • High-speed data acquisition – transmits turbine operational data to modern SCADA systems at higher baud rates for real-time monitoring.

  • Multi-vendor environments – interfaces with various third-party devices using different protocols and interfaces.

  • Offshore and harsh environments – ruggedized design and extended temperature range make it suitable for demanding applications.

  • Retrofits – the DS3800XJBC1A1A allows legacy Mark IV systems to connect to modern control networks with enhanced protocol support.


vs Competitors & Previous Variants

Feature DS3800XJBC1A1A DS3800XJBC DS3800XJBA1A1A Generic VME Serial Board
Serial ports 4 4 4 2–4
Max baud rate 921.6 kbps 115.2 kbps 921.6 kbps 115.2 kbps
Protocols Modbus, GE, DNP3, IEC 101, ASCII Modbus, GE, DNP3, IEC 101, ASCII Modbus, GE, DNP3, ASCII Varies
Isolation 2500V 2500V 2500V 500–1000V
Ruggedized/conformal coat Yes Yes Yes Rarely
Diagnostic detail Enhanced (1A1A) Standard Enhanced Basic
Fault logging Yes (1A1A) Limited Limited No
Self-test Yes Yes Yes No
Temp range –40°C to +85°C –40°C to +85°C –40°C to +85°C 0°C to +60°C
Firmware revision 1A1A Varies 1A1A N/A

Selection Tips

  • Utility/transmission applications – choose the DS3800XJBC1A1A for substation or transmission applications where DNP3 or IEC 60870-5-101 protocols are required, combined with high-speed communication needs.

  • High-speed communication + ruggedness – this board combines the ruggedized design of the DS3800XJBC with the higher baud rates of the DS3800XJBA1A1A, making it the most capable communication board in the Mark IV lineup.

  • Harsh environments – the ruggedized, conformal-coated design makes this board ideal for offshore, desert, or chemically aggressive sites.

  • Enhanced diagnostics – the 1A1A firmware provides improved fault logging and diagnostic reporting, aiding predictive maintenance and troubleshooting.

  • Firmware compatibility – confirm your Mark IV main processor firmware supports the enhanced diagnostic and protocol features of the General Electric DS3800XJBC1A1A.

  • Power budget verification – the DS3800XJBC1A1A draws more power than standard communication boards due to advanced features; verify your backplane power capacity.

  • Spare strategy – keep one DS3800XJBC1A1A per 5–8 installed units, especially in communication-heavy or critical installations.

  • Configuration documentation – document the protocol, interface, and baud rate settings for each of the 4 ports for easy replacement and troubleshooting.


Critical Precautions

  • Interface selection – ensure each port’s RS-232/422/485 jumpers are correctly set before connecting field devices. Incorrect settings can damage the DS3800XJBC1A1A or connected devices.

  • Cable length limits – RS-232: <15 m; RS-422/485: <1200 m. Higher baud rates may require shorter cable lengths; consult the General Electric DS3800XJBC1A1A technical manual for derating guidelines.

  • Grounding – for RS-485 multi-drop networks, ensure proper termination resistors (120Ω) are installed at each end of the bus to prevent reflections and signal degradation.

  • Shielded cabling – use shielded twisted-pair cables for RS-422/485 connections. Ground the shield only at the DS3800XJBC1A1A end to prevent ground loops.

  • Address configuration – when using Modbus RTU, DNP3, or IEC 60870-5-101, ensure each device has a unique slave address on each network.

  • Data format matching – verify that data bits, stop bits, and parity settings on the DS3800XJBC1A1A match each external device exactly; mismatched settings cause communication failures.

  • Protocol version compatibility – when using DNP3 or IEC 60870-5-101, confirm that the firmware version supports the specific protocol sub-version required by your external devices.

  • Bandwidth management – with 4 ports at higher baud rates, the DS3800XJBC1A1A can generate significant backplane traffic. Ensure your Mark IV processor can handle the data throughput.

  • Self-test – allow the DS3800XJBC1A1A to complete its power-up self-test (~2 seconds) before relying on communications.

  • Heat dissipation – ensure adequate cabinet cooling (>250 CFM) if multiple advanced communication boards are installed.

  • Hot-swap – never insert or remove the DS3800XJBC1A1A while the rack is powered; this can cause communication buffer corruption or damage.

  • ESD handling – always use a grounded wrist strap; serial interface chips are ESD-sensitive.

  • Storage – store spare DS3800XJBC1A1A boards in anti-static bags in a dry, temperature-controlled environment.

A-B 1756-BA2
A-B 1756-BA2
A-B 1756-BA2
ABB 3HAC025466-001

Reviews

There are no reviews yet.

Be the first to review “GE DS3800XJBC1A1A”

Your email address will not be published. Required fields are marked *

Post comment