Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 125 VDC nominal (range 100–150 VDC); 24 VDC compatible with external adapter |
| Output Rails | +5 VDC / 20A, ±15 VDC / 4A (each rail), +24 VDC / 1.5A (auxiliary field power) |
| Isolation | Partial isolation – opto-isolated analog feedback channels (3 channels); main power path remains non-isolated |
| Analog Feedback | 3 differential analog inputs (0–10V / 4–20mA configurable) for triple-redundant power health monitoring |
| Digital Interface | 1 digital output (open-collector, 24V/100mA) for external alarm/fan control |
| Operating Temperature | –30°C to +65°C |
| Form Factor | 6U × 8HP (40mm) – requires 2 slots |
| Backplane Connector | Standard VME 96-pin P1 + reinforced 60-pin P2 (high-current) |
| Status LEDs | 5 indicators: PWR OK (green), OVP (red), TEMP (yellow), ISO OK (blue), AUX OK (purple – +24V rail) |
| Certifications | CE, UL 508 (non-hazardous locations only) |
| Efficiency | ~85% at full load |
Critical note: The DS3800NPSJ1A1A is physically wider (8HP) than all NPSE boards. It does not fit in standard 4HP slots. Installation requires two adjacent empty slots in the Mark IV/V rack. Hot-swapping is not supported. This is the base revision—later versions offer improved isolation, diagnostics, and thermal performance.
Key Features & Advantages
-
High Capacity for Main Racks – With +5V at 20A and ±15V at 4A, the DS3800NPSJ1A1A delivers substantial power (~200W) to support densely populated main control cabinets with CPU, communications, and multiple servo driver cards.
-
Triple-Redundant Health Monitoring – Three isolated analog feedback channels provide redundancy for power quality reporting. If one channel drifts, the CPU can flag a warning while continuing to rely on the other two.
-
Auxiliary +24V Field Power – A dedicated 24V/1.5A output provides power for external field devices (e.g., proximity sensors, pressure switches), reducing the need for separate field power supplies.
-
Direct Drop-In for Legacy Systems – The DS3800NPSJ1A1A is pin-compatible with all Mark IV backplanes that support 8HP boards, making it a straightforward replacement for failed NPSJ units in older installations.
-
Proven Reliability – As the original NPSJ design, this board benefits from extensive field data and well-documented maintenance procedures.
-
Digital Alarm Output – The open-collector digital output can be configured (via onboard jumpers) to trigger external alarms for OVP, OCP, or overtemperature conditions.
Typical Application Cases
-
Main Mark IV Control Cabinets – Installed in the first slot of the main rack to power the CPU board (e.g., DS3800NMP), communications modules, and I/O cards in legacy installations commissioned before 2005.
-
Frame 6B/7E Gas Turbine Main Racks – Powers servo valve driver cards and vibration monitoring interfaces in older Frame 6B and 7E turbines.
-
Steam Turbine Main Control Cabinets – Supplies power to high-density racks with LVDT drivers, thermocouple amplifiers, and speed detection circuits.
-
Legacy Fleet Replacement – When an NPSJ board fails, the DS3800NPSJ1A1A is the baseline replacement for plants that do not require the enhanced features of later revisions.
-
Test Benches and Simulators – Used in laboratory environments to emulate field power supply characteristics for control algorithm validation.
Competitive Comparison
| Aspect | DS3800NPSJ1A1A (GE) | DS3800NPSJ (later revision) | DS3800NPSE1E1G (GE) |
|---|---|---|---|
| +5V Output | 20A | 25A | 16A |
| ±15V Output | 4A each | 5A each | 2.5A each |
| Auxiliary Output | +24V / 1.5A | +24V / 2A | None |
| Isolation | Partial (feedback only) | Full (2.0kV) | Partial (feedback only) |
| Feedback Channels | 3 (isolated) | 4 (isolated) | 3 (isolated) |
| Form Factor | 8HP (2 slots) | 8HP (2 slots) | 4HP (1 slot) |
| Relay Outputs | None (open-collector only) | 2 relay (form-C, 1A) | None |
| Operating Temp | –30°C to +65°C | –40°C to +70°C | –40°C to +70°C |
| Efficiency | ~85% | ~88% | ~87% |
| Diagnostics | LEDs only | Ethernet + logging | LEDs only |
| CSA Div 2 | No | Yes | Yes |
| Capacitor Lifetime | 10,000h @65°C | 18,000h @65°C | 20,000h @65°C |
| Price (refurb) | ~$4,500–$6,500 | ~$6,000–$9,000 | ~$3,800–$5,000 |
The DS3800NPSJ1A1A is a capable but aging design—it provides high power and partial isolation but lacks the full isolation, Ethernet diagnostics, and extended temperature range of later NPSJ revisions.
Selection Guidelines & Precautions
-
Physical Compatibility – Critical Check – The DS3800NPSJ1A1A is 8HP wide, requiring two adjacent empty slots in your Mark IV/V rack. Verify your main rack has sufficient space. This board will not fit in standard 4HP slots.
-
Backplane Compatibility – This board uses both the standard 96-pin P1 connector and a reinforced 60-pin P2 high-current connector. If your backplane lacks P2 (most pre-2005 racks), the +24V auxiliary rail will be unavailable. The board will still function for +5V and ±15V outputs.
-
Partial Isolation Limitations – The isolation only applies to feedback channels, not main power outputs. Maintain a single-point ground (< 1Ω) for the entire cabinet. If you have severe grounding issues affecting actual loads, consider upgrading to a fully isolated later revision.
-
No Ethernet Diagnostics – The DS3800NPSJ1A1A lacks predictive failure analytics. Perform manual ESR checks on primary capacitors every 6 months. Replace the board if ESR exceeds 2× initial value.
-
Thermal Derating – Full 20A output available up to 55°C:
-
55°C – 60°C: derate +5V to 18A, ±15V to 3.5A, +24V to 1.3A
-
60°C – 65°C: derate +5V to 15A, ±15V to 3.0A, +24V to 1.0A
-
Above 65°C: do not operate
-
-
Digital Output Configuration – Onboard jumper JP1 configures the open-collector output:
-
JP1-1/2: Alarm on OVP
-
JP1-3/4: Alarm on OCP
-
JP1-5/6: Alarm on overtemperature
Set jumpers as needed. The output is active-low (sinks to ground), rated for 24V/100mA.
-
-
Input Power Sizing – At 20A +5V output, maximum input current at 100VDC is approximately 5.0A. Use a 10A slow-blow circuit breaker and cable gauge ≥ 4.0mm².
-
Spare Sourcing – Production ended in 2010. When purchasing refurbished units, require:
-
Load test report (20A +5V, 4A ±15V, 1.5A +24V) at 25°C and 55°C
-
Ripple measurements: < 25mVpp (+5V), < 15mVpp (±15V), < 30mVpp (+24V)
-
P2 connector inspection (no bent or corroded pins)
-
Visual inspection for capacitor bulging, transformer discoloration, or PCB stress cracks
-
Warranty covering at least 6 months
-

SIEMENS 6ES7972-0BB50-0XA0 Ϊ6ES7972-0BB52-0XA0
YASKAWA JVOP-160


Reviews