Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NLIA1F1E |
| Power Supply | +5V DC @ 4.5A, +15V DC @ 1.0A, -15V DC @ 0.8A |
| Temperature Inputs | 4 thermocouple + 8 RTD = 12 total channels (24-bit ADC, ±0.5°C / ±0.3°C) |
| Fan Outputs | 8 solid-state relays, 3A continuous @ 24–48VDC (surge 5A) with self-healing |
| Tachometer Inputs | 2 channels (up to 15 kHz) |
| Communication | Dual-redundant backplane paths |
| Operating Temperature | -40°C to +85°C |
| Vibration Resistance | 5g RMS (MIL-STD-810G) |
| Fault Log | 500 events |
| LED Indicators | Power, Fan Run (8x green), SS Overcurrent (flashing red), Tach Fail, RTD Fault, Predictive Model Active, Self-Heal Active, Redundant Path Active, Over-Temp Alarm, Backplane Active, Bus Fault |
Advantages and Distinctive Features
-
3A Solid-State Outputs: Highest current capacity in the NLIA family with self-healing diagnostics.
-
Dual Temperature Sensor Support (4 T/C + 8 RTD): 12 total channels for flexible monitoring.
-
Redundant Backplane Communication: Dual paths with automatic failover (<50ms).
-
Self-Healing Diagnostics: Automatic output reset after transient faults (up to 3 resets/24hrs).
-
Predictive Thermal Modeling: Learns cabinet thermal response during 24-hour initial period.
-
Tachometer Feedback: Dual-channel speed verification.
-
RTD Fault Detection: Open/short/lead-wire degradation monitoring.
-
24-Bit Ultra-High Precision ADC: ±0.5°C / ±0.3°C accuracy.
-
Silent, Maintenance-Free Operation: Unlimited switching cycles.
-
500-Event Fault Log: Comprehensive diagnostics.
Typical Application Fields
-
Mission-Critical DC Cooling Systems: Where fault tolerance and maximum solid-state current are required.
-
High-Cycle Applications: Unlimited switching life with self-healing.
-
Offshore Oil & Gas Platforms: Extreme environments with redundant communication.
-
Nuclear Auxiliary Turbines: High reliability with self-healing and redundant paths.
-
Extreme Desert & Arctic Installations: -40°C to +85°C range.
Comparison with Related Models
| Feature | DS3800NLIA1F1E | DS3800NLIA (Base) | DS3800NITA1C1D | DS3800NFMC1F1E |
|---|---|---|---|---|
| Output Current | 3A | 2A | 2A | 3A |
| T/C + RTD Inputs | 4 + 8 = 12 | 4 + 0 = 4 | 4 + 0 = 4 | 8 + 0 = 8 |
| Tach Inputs | 2 channels | 2 channels | 2 channels | 2 channels |
| Redundant Comms | Yes | No | No | No |
| Self-Healing | Yes | No | No | No |
| Predictive Modeling | Yes | No | No | Yes |
| Operating Temp | -40°C to +85°C | 0°C to +60°C | -40°C to +75°C | -40°C to +75°C |
| Fault Log | 500 events | Basic | 200 events | 200 events |
| Cost | Ultra-Premium+ | Medium | High | High |
Selection Recommendations
-
Choose the DS3800NLIA1F1E if:
-
You need the highest DC solid-state current (3A) .
-
You require redundant backplane communication for fault tolerance.
-
You want self-healing diagnostics for automatic fault recovery.
-
You require dual-sensor temperature monitoring (4 T/C + 8 RTD).
-
You require tachometer feedback.
-
Your installation operates in extreme heat up to +85°C .
-
-
Choose the DS3800NFMC1F1E if: You need 3A SS outputs, 8 thermocouple inputs, and predictive modeling but do not require redundant comms or self-healing.
-
Choose the DS3800NITA1C1D if: You need 2A SS outputs with tachometer feedback in a moderately harsh environment (-40°C to +75°C).
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.
-
DC Polarity: Solid-state outputs are DC-only and polarity-sensitive. Reverse polarity destroys the output MOSFET.
-
Voltage Limit: Do not exceed 48VDC—AC voltages cause catastrophic failure.
-
Current Derating: At 85°C, derate to 2.2A per output.
-
RTD Wiring: Use 3-wire Pt100 RTDs—all three wires must be connected.
-
Redundant Paths: Both backplane paths must be connected for full fault tolerance.
-
Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.
-
Tachometer Wiring: Use shielded twisted-pair cable.
-
Predictive Model Learning: Requires 24-hour initial learning—do not interrupt power.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Compatibility: Requires Mark V CPU firmware v6.0 or higher for full features.
-
Power Supply: Draws 4.5A on +5V rail—verify sufficient capacity.

OMRON CQM1-PD026
A-B 1746-OW16
A-B 1794-OB16


Reviews