GE DS3800NLIA1F1E

¥999.00

The DS3800NLIA1F1E is the absolute flagship of General Electric’s Mark V series Fan/Exhaust Control boards for standard-voltage DC applications. The suffix “1F1E” indicates Revision F firmware with 24-bit ADC (±0.5°C / ±0.3°C), extended temperature components (-40°C to +85°C), military-grade vibration tolerance (5g RMS), 3A solid-state outputs4 thermocouple input channels8 RTD input channels (12 total temperature channels), 2 tachometer inputspredictive thermal modelingredundant backplane communication paths, and self-healing diagnostics for solid-state output channels.

The DS3800NLIA1F1E represents the ultimate solid-state DC fan control solution, combining maximum output current (3A), dual-sensor temperature monitoring, tachometer feedback, predictive modeling, fault-tolerant communication, and self-healing capability.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NLIA1F1E
Power Supply +5V DC @ 4.5A, +15V DC @ 1.0A, -15V DC @ 0.8A
Temperature Inputs 4 thermocouple + 8 RTD = 12 total channels (24-bit ADC, ±0.5°C / ±0.3°C)
Fan Outputs 8 solid-state relays, 3A continuous @ 24–48VDC (surge 5A) with self-healing
Tachometer Inputs 2 channels (up to 15 kHz)
Communication Dual-redundant backplane paths
Operating Temperature -40°C to +85°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 500 events
LED Indicators Power, Fan Run (8x green), SS Overcurrent (flashing red), Tach Fail, RTD Fault, Predictive Model Active, Self-Heal Active, Redundant Path Active, Over-Temp Alarm, Backplane Active, Bus Fault

Advantages and Distinctive Features

  • 3A Solid-State Outputs: Highest current capacity in the NLIA family with self-healing diagnostics.

  • Dual Temperature Sensor Support (4 T/C + 8 RTD): 12 total channels for flexible monitoring.

  • Redundant Backplane Communication: Dual paths with automatic failover (<50ms).

  • Self-Healing Diagnostics: Automatic output reset after transient faults (up to 3 resets/24hrs).

  • Predictive Thermal Modeling: Learns cabinet thermal response during 24-hour initial period.

  • Tachometer Feedback: Dual-channel speed verification.

  • RTD Fault Detection: Open/short/lead-wire degradation monitoring.

  • 24-Bit Ultra-High Precision ADC: ±0.5°C / ±0.3°C accuracy.

  • Silent, Maintenance-Free Operation: Unlimited switching cycles.

  • 500-Event Fault Log: Comprehensive diagnostics.


Typical Application Fields

  • Mission-Critical DC Cooling Systems: Where fault tolerance and maximum solid-state current are required.

  • High-Cycle Applications: Unlimited switching life with self-healing.

  • Offshore Oil & Gas Platforms: Extreme environments with redundant communication.

  • Nuclear Auxiliary Turbines: High reliability with self-healing and redundant paths.

  • Extreme Desert & Arctic Installations: -40°C to +85°C range.


Comparison with Related Models

Feature DS3800NLIA1F1E DS3800NLIA (Base) DS3800NITA1C1D DS3800NFMC1F1E
Output Current 3A 2A 2A 3A
T/C + RTD Inputs 4 + 8 = 12 4 + 0 = 4 4 + 0 = 4 8 + 0 = 8
Tach Inputs 2 channels 2 channels 2 channels 2 channels
Redundant Comms Yes No No No
Self-Healing Yes No No No
Predictive Modeling Yes No No Yes
Operating Temp -40°C to +85°C 0°C to +60°C -40°C to +75°C -40°C to +75°C
Fault Log 500 events Basic 200 events 200 events
Cost Ultra-Premium+ Medium High High

Selection Recommendations

  • Choose the DS3800NLIA1F1E if:

    • You need the highest DC solid-state current (3A) .

    • You require redundant backplane communication for fault tolerance.

    • You want self-healing diagnostics for automatic fault recovery.

    • You require dual-sensor temperature monitoring (4 T/C + 8 RTD).

    • You require tachometer feedback.

    • Your installation operates in extreme heat up to +85°C .

  • Choose the DS3800NFMC1F1E if: You need 3A SS outputs, 8 thermocouple inputs, and predictive modeling but do not require redundant comms or self-healing.

  • Choose the DS3800NITA1C1D if: You need 2A SS outputs with tachometer feedback in a moderately harsh environment (-40°C to +75°C).


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.

  • DC Polarity: Solid-state outputs are DC-only and polarity-sensitive. Reverse polarity destroys the output MOSFET.

  • Voltage Limit: Do not exceed 48VDC—AC voltages cause catastrophic failure.

  • Current Derating: At 85°C, derate to 2.2A per output.

  • RTD Wiring: Use 3-wire Pt100 RTDs—all three wires must be connected.

  • Redundant Paths: Both backplane paths must be connected for full fault tolerance.

  • Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.

  • Tachometer Wiring: Use shielded twisted-pair cable.

  • Predictive Model Learning: Requires 24-hour initial learning—do not interrupt power.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Compatibility: Requires Mark V CPU firmware v6.0 or higher for full features.

  • Power Supply: Draws 4.5A on +5V rail—verify sufficient capacity.

OMRON CQM1-PD026
A-B 1746-OW16
A-B 1794-OB16

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NLIA1F1E”

Your email address will not be published. Required fields are marked *