GE DS3800NLCA1F1F

¥999.00

The DS3800NLCA1F1F is the absolute flagship of General Electric’s Mark V series Fan/Exhaust Control boards for standard-voltage AC/DC applications. The suffix “1F1F” indicates Revision F firmware with 24-bit ADC (±0.5°C / ±0.3°C), extended temperature components (-40°C to +85°C), military-grade vibration tolerance (5g RMS), 8A mechanical relay outputs4 thermocouple input channels8 RTD input channels (12 total temperature channels), 2 tachometer inputspredictive relay maintenance, and predictive thermal modeling.

The “F” suffix also indicates redundant backplane communication paths for fault-tolerant operation and self-healing diagnostics for relay channels—making this board the ultimate solution for mission-critical AC/DC fan control.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NLCA1F1F
Power Supply +5V DC @ 5.0A, +15V DC @ 1.2A, -15V DC @ 1.0A
Temperature Inputs 4 thermocouple + 8 RTD = 12 total channels (24-bit ADC, ±0.5°C / ±0.3°C)
Fan Outputs 8 mechanical relays, 8A continuous @ 115VAC/30VDC (surge 15A) with predictive maintenance
Tachometer Inputs 2 channels (up to 15 kHz)
Communication Dual-redundant backplane paths
Operating Temperature -40°C to +85°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 500 events
LED Indicators Power, Fan Run (8x amber), Tach Fail, RTD Fault, Relay Degradation, Predictive Model Active, Self-Heal Active, Redundant Path Active, Over-Temp Alarm, Backplane Active, Bus Fault

Advantages and Distinctive Features

  • 8A Mechanical Relays: Highest current capacity in the NLCA family—supports 1HP AC fans or heavy DC loads.

  • Dual Temperature Sensor Support (4 T/C + 8 RTD): 12 total channels for flexible or redundant monitoring.

  • Redundant Backplane Communication: Dual paths with automatic failover (<50ms) for fault-tolerant operation.

  • Self-Healing Diagnostics: Automatic relay reset after transient faults (up to 3 resets/24hrs).

  • Predictive Thermal Modeling: Learns cabinet thermal response during 24-hour initial period, reducing temperature overshoot by up to 50%.

  • Predictive Relay Maintenance: Real-time contact resistance monitoring with degradation warning.

  • Tachometer Feedback: Dual-channel speed verification.

  • RTD Fault Detection: Open/short/lead-wire degradation monitoring.

  • 500-Event Fault Log: Comprehensive diagnostics.


Typical Application Fields

  • Mission-Critical AC/DC Cooling Systems: Where fault tolerance and maximum relay current are required.

  • High-Power Fan Applications: 8A capacity for 1HP AC fans or large DC blowers.

  • Offshore Oil & Gas Platforms: Extreme environments with redundant communication.

  • Nuclear Auxiliary Turbines: High reliability with self-healing and redundant paths.

  • Extreme Desert & Arctic Installations: -40°C to +85°C range.


Comparison with Related Models

Feature DS3800NLCA1F1F DS3800NLCA1E1E DS3800NHVP1B1B DS3800NISA1C1C
Relay Current 8A @ 115VAC/30VDC 5A @ 115VAC/30VDC 5A @ 125VDC N/A (SS)
T/C + RTD Inputs 4 + 8 = 12 4 + 8 = 12 8 + 8 = 16 4 + 0 = 4
Tach Inputs 2 channels 2 channels 2 channels None
Redundant Comms Yes No No No
Self-Healing Yes No No No
Predictive Modeling Yes Yes No No
Operating Temp -40°C to +85°C -40°C to +85°C -20°C to +65°C -40°C to +75°C
Fault Log 500 events 500 events 200 events 200 events
Cost Ultra-Premium+ Ultra-Premium Ultra-Premium+++ High

Selection Recommendations

  • Choose the DS3800NLCA1F1F if:

    • You need the highest AC/DC relay current (8A) for 1HP fans.

    • You require redundant backplane communication for fault tolerance.

    • You want self-healing diagnostics for automatic fault recovery.

    • You require dual-sensor temperature monitoring (4 T/C + 8 RTD).

    • You require tachometer feedback.

    • Your installation operates in extreme heat up to +85°C .

  • Choose the DS3800NLCA1E1E if: You need 5A relays, 12 temperature channels, and predictive modeling but do not require redundant comms or self-healing.

  • Choose the DS3800NHVP1B1B if: You need high-voltage DC (125VDC) with 5A relays and 16 temperature channels.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • High-Voltage/Current Hazard: Relay outputs switch up to 115VAC / 8A—lethal voltage/current present. Use proper insulation and safety procedures.

  • RTD Wiring: Use 3-wire Pt100 RTDs—all three wires must be connected.

  • Relay Derating: For inductive fan motors, derate from 8A to 6A or use RC snubbers.

  • Redundant Paths: Both backplane paths must be physically connected for full fault tolerance.

  • Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.

  • Tachometer Wiring: Use shielded twisted-pair cable.

  • Predictive Model Learning: Requires 24-hour initial learning—do not interrupt power.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Compatibility: Requires Mark V CPU firmware v6.0 or higher for full features.

  • Power Supply: Draws 5.0A on +5V rail—verify sufficient capacity.

A-B 1786-TPS
GE IC200PWR102
ABB TU515

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NLCA1F1F”

Your email address will not be published. Required fields are marked *

Post comment