The DS3800NLCA is a Fan/Exhaust Control board from General Electric’s Mark V Speedtronic™ series, designed for standard-voltage AC/DC applications with mechanical relay outputs and tachometer feedback. The “NLCA” designation indicates a board with:

  • 8 mechanical relays (3A @ 115VAC / 30VDC) for fan control

  • 4 thermocouple input channels for temperature monitoring

  • 2 tachometer input channels for fan speed verification

  • 12-bit ADC (±2°C accuracy)

  • Standard temperature range (0°C to +60°C)

The DS3800NLCA is a cost-effective, relay-based fan control board that adds tachometer feedback to the fan-dense “NLBA” design, allowing the Mark V CPU to verify actual fan rotation for safety-critical applications.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NLCA
Power Supply +5V DC @ 3.2A, +15V DC @ 0.5A, -15V DC @ 0.3A
Temperature Inputs 4 thermocouple channels (12-bit ADC, ±2°C accuracy)
Fan Outputs 8 mechanical relays, 3A continuous @ 115VAC/30VDC (surge 5A)
Tachometer Inputs 2 channels (up to 10 kHz)
Communication Mark V proprietary parallel backplane bus
Operating Temperature 0°C to +60°C
LED Indicators Power, Fan Run (8x amber), Tach Fail (red x2), Over-Temp Alarm, Backplane Active

Advantages and Distinctive Features

  • Tachometer Feedback: Dual tachometer inputs allow the CPU to confirm fan operation—critical for safety-critical cooling systems.

  • AC/DC Output Capability: Switches both AC (115VAC) and DC (30VDC) loads—versatile for mixed cabinet installations.

  • Fan-Dense Design: 8 outputs with only 4 temperature inputs—optimized for single-zone cooling with speed verification.

  • Mechanical Relay Isolation: 2500V galvanic isolation between control logic and fan power.

  • High Surge Handling: 5A surge capacity for fan startup currents.

  • CPU-Dependent Operation: No onboard logic—simple and cost-effective.


Typical Application Fields

  • Safety-Critical AC/DC Cooling Systems: Where fan failure must be detected immediately.

  • Fan-Dense Cabinets: Where 8 fans serve a single zone with 4 sensors.

  • Mixed AC/DC Fan Installations: Where both AC and DC fans are present.

  • Climate-Controlled Indoor Installations: 0°C to +60°C range.


Comparison with Related Models

Feature DS3800NLCA DS3800NLBA DS3800NITA DS3800NFLA
Output Type Mechanical relay Mechanical relay Solid-state Mechanical relay
Output Current 3A 3A 2A 3A
T/C Inputs 4 4 4 8
Tach Inputs 2 channels None 2 channels 2 channels
AC Capability Yes Yes No Yes
ADC 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C)
Operating Temp 0°C to +60°C 0°C to +60°C 0°C to +60°C 0°C to +60°C
Cost Medium Low Medium Medium

Selection Recommendations

  • Choose the DS3800NLCA if:

    • You need 3A mechanical relay outputs (AC or DC).

    • Your cabinet uses 4 temperature sensors for 8 fan outputs.

    • You require tachometer feedback for fan speed verification.

    • You have a climate-controlled environment (0°C to +60°C).

    • The Mark V CPU handles all control logic.

  • Choose the DS3800NLBA if: You need the same design but do not require tachometer feedback.

  • Choose the DS3800NITA if: You prefer solid-state DC outputs with tachometer feedback.

  • Choose the DS3800NFLA if: You need 8 thermocouple inputs with relay outputs and tachometer feedback.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • Relay Contact Wear: Rated for 100,000 operations at 3A.

  • Inductive Load Derating: For inductive fan motors, derate to 2A or use external RC snubbers.

  • Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.

  • Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal—not at the fan end.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—tachometer monitoring disabled in fallback mode.

  • Firmware Compatibility: Compatible with all Mark V CPU firmware versions (v3.x and above).

A-B 1786-TPS
MITSUBISHI Q61P
GE IC200ACC003