Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NHVM1C1C |
| Power Supply | +5V DC @ 5.4A, +15V DC @ 1.1A, -15V DC @ 0.9A |
| Temperature Inputs | 4 thermocouple + 8 RTD = 12 total channels (24-bit ADC, ±0.5°C / ±0.3°C) |
| Relay Outputs | 8 mechanical relays, 3A continuous @ 125VDC (surge 6A) with predictive maintenance |
| SS Outputs | 4 solid-state relays, 3A continuous @ 24–48VDC |
| Tachometer Inputs | 2 channels with enhanced filtering (up to 10 kHz) |
| Communication | Mark V proprietary parallel backplane bus |
| Operating Temperature | -40°C to +75°C |
| Vibration Resistance | 5g RMS (MIL-STD-810G) |
| Fault Log | 500 events |
| LED Indicators | Power, Relay Run (8x amber), SS Run (4x green), Tach Fail (red x2), RTD Fault (yellow), Relay Degradation (orange), Over-Temp Alarm, Backplane Active, Bus Fault |
Advantages and Distinctive Features
-
Highest Relay Current (3A @ 125VDC): Delivers 3A continuous (6A surge)—the highest current capacity of any high-voltage DC fan board.
-
RTD-Optimized Temperature Monitoring (4 T/C + 8 RTD): 12 total temperature channels—ideal for applications where RTD sensors are preferred.
-
24-Bit Ultra-High Precision ADC: ±0.5°C for thermocouples, ±0.3°C for RTDs.
-
Predictive Relay Maintenance: Real-time contact resistance monitoring with relay degradation warning.
-
Hybrid Output + Tachometer Feedback: Combines 8 high-voltage DC relay outputs, 4 high-current solid-state outputs, AND 2 tachometer inputs.
-
RTD Fault Detection: Continuous monitoring for open-circuit, short-circuit, or lead-wire degradation.
-
Extended Environmental Tolerance: -40°C to +75°C with 5g vibration resistance.
-
500-Event Fault Log: Comprehensive diagnostics.
Typical Application Fields
-
High-Power 125VDC Cooling Systems: Where 3A @ 125VDC capacity is required for large exhaust fans.
-
RTD-Heavy High-Voltage Cabinets: Where RTD sensors are preferred over thermocouples.
-
Safety-Critical Cooling Systems: With redundant RTD-based temperature monitoring and fan failure detection.
-
Offshore Oil & Gas Platforms: Extreme temperature and vibration environments.
-
Arctic & Desert Installations: -40°C to +75°C range.
-
Nuclear Auxiliary Turbines: High reliability with RTD-based monitoring.
Comparison with Related Models
| Feature | DS3800NHVM1C1C | DS3800NHVM1B1B | DS3800NHVM1B1A | DS3800NHVL1C1C |
|---|---|---|---|---|
| Relay Current | 3A @ 125VDC | 3A @ 125VDC | 3A @ 125VDC | 2A @ 125VDC |
| Relay Surge | 6A | 6A | 6A | 4A |
| SS Outputs | 4 × 3A @ 48VDC | 4 × 3A @ 48VDC | 4 × 3A @ 48VDC | 4 × 3A @ 48VDC |
| T/C + RTD Inputs | 4 + 8 = 12 | 8 + 8 = 16 | 8 + 8 = 16 | 4 + 8 = 12 |
| ADC Resolution | 24-bit | 24-bit | 24-bit | 24-bit |
| Predictive Maintenance | Yes | Yes | Yes | Yes |
| Operating Temp | -40°C to +75°C | -20°C to +65°C | 0°C to +60°C | -40°C to +75°C |
| Vibration | 5g RMS | 2g RMS | 1g RMS | 5g RMS |
| Fault Log | 500 events | 200 events | 200 events | 500 events |
| Firmware | C | B | B | C |
| Cost | Ultra-Premium+ | Ultra-Premium | Ultra-Premium | Ultra-Premium |
Selection Recommendations
-
Choose the DS3800NHVM1C1C if:
-
You need the highest 125VDC relay current (3A) for powerful exhaust fans.
-
You need high-current solid-state outputs (3A @ 48VDC) .
-
You require RTD inputs (8 channels) but only need 4 thermocouple inputs (12 total channels).
-
You require tachometer feedback for fan speed verification.
-
You want predictive relay maintenance.
-
You need 24-bit ADC accuracy.
-
Your installation is in extreme environments (-40°C to +75°C) with high vibration.
-
You need 500-event fault logging.
-
-
Choose the DS3800NHVM1B1B if: You need the same 3A relay current and 16 temperature channels but operate in a moderately harsh environment (-20°C to +65°C).
-
Choose the DS3800NHVL1C1C if: You need 2A relay current with RTD-heavy monitoring and extreme temperature tolerance.
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.
-
High-Voltage Hazard: Relay outputs switch 125VDC—lethal voltage present on terminals. Observe all high-voltage safety procedures. Use wiring rated for ≥125VDC.
-
Missing Thermocouple Channels: The DS3800NHVM1C1C has only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent—do not attempt to connect T/C sensors.
-
RTD Wiring: Use 3-wire Pt100 RTDs. All three wires must be connected. Open/short circuits trigger RTD Fault LED.
-
RTD Lead Resistance: Use wire with resistance ≤10Ω per lead.
-
DC Polarity (Relay): Relay outputs are DC only—observe correct polarity.
-
DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.
-
Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal.
-
Relay Current Limitation: Rated at 3A continuous @ 125VDC. Verify fan current does not exceed this limit.
-
SS Current Limitation: Rated at 3A continuous @ 24–48VDC. At 75°C, derate to 2.2A.
-
Inductive Load Derating (Relay): For inductive fan motors, derate to 2A or use external RC snubbers (rated for 125VDC).
-
No AC Connection: Do not connect AC loads to either output type.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—all advanced features disabled in fallback mode.
-
Firmware Compatibility: The DS3800NHVM1C1C requires Mark V CPU firmware v5.5 or higher for full 24-bit ADC, predictive maintenance, and RTD support. For v5.0–v5.4, predictive maintenance disabled (ADC and RTD still function). For v4.x, reverts to 16-bit mode.
-
Power Supply: Draws 5.4A on +5V rail—a power supply upgrade is mandatory for most installations.

A-B 1746-C16
GE IC200CHS022
A-B 1786-TPS


Reviews
There are no reviews yet.