GE DS3800NHVM1B1A

¥999.00

The DS3800NHVM1B1A is a revision of General Electric’s Mark V series Fan/Exhaust Control board, engineered for high-voltage DC applications with a hybrid output configuration. The suffix “1B1A” indicates Revision B firmware with 24-bit ADC (±0.5°C / ±0.3°C accuracy), standard temperature components (0°C to +60°C), and the hybrid + tachometer + RTD architecture. This board provides:

  • 8 mechanical relays (3A @ 125VDC)—the highest relay current in the high-voltage DC lineup

  • 4 solid-state outputs (3A @ 24–48VDC) for high-current auxiliary fans or alarms

  • 8 thermocouple input channels for temperature monitoring

  • 8 RTD input channels (Pt100, 3-wire) for high-precision temperature monitoring—adding 16 total temperature channels

  • 2 tachometer input channels for fan speed verification

The DS3800NHVM1B1A combines the highest relay current (3A @ 125VDC) with dual-sensor temperature monitoring, high-current solid-state outputs, tachometer feedback, and 24-bit ADC accuracy—all in a climate-controlled package.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NHVM1B1A
Power Supply +5V DC @ 5.5A, +15V DC @ 1.2A, -15V DC @ 1.0A
Temperature Inputs 8 thermocouple + 8 RTD = 16 total channels (24-bit ADC, ±0.5°C / ±0.3°C)
Relay Outputs 8 mechanical relays, 3A continuous @ 125VDC (surge 6A) with predictive maintenance
SS Outputs 4 solid-state relays, 3A continuous @ 24–48VDC
Tachometer Inputs 2 channels with enhanced filtering (up to 10 kHz)
Communication Mark V proprietary parallel backplane bus
Operating Temperature 0°C to +60°C
Fault Log 200 events
LED Indicators Power, Relay Run (8x amber), SS Run (4x green), Tach Fail (red x2), RTD Fault (yellow), Relay Degradation Warning (orange), Over-Temp Alarm, Backplane Active, Bus Fault

Advantages and Distinctive Features

  • Highest Relay Current (3A @ 125VDC): Delivers 3A continuous (6A surge)—the highest current capacity of any high-voltage DC fan board in the Mark V lineup.

  • Dual Temperature Sensor Support (T/C + RTD): 8 thermocouple + 8 RTD inputs (16 total channels).

  • 24-Bit Ultra-High Precision ADC: ±0.5°C for thermocouples, ±0.3°C for RTDs.

  • Predictive Relay Maintenance: Real-time contact resistance monitoring with relay degradation warning.

  • Hybrid Output + Tachometer Feedback: Combines 8 high-voltage DC relay outputs, 4 high-current solid-state outputs, AND 2 tachometer inputs.

  • RTD Fault Detection: Continuous monitoring for open-circuit, short-circuit, or lead-wire degradation.

  • 200-Event Fault Log: Comprehensive diagnostics.


Typical Application Fields

  • High-Power 125VDC Cooling Systems: Where 3A @ 125VDC capacity is required for large exhaust fans.

  • Safety-Critical Cooling Systems: With redundant temperature sensing and fan failure detection.

  • Climate-Controlled Indoor Installations: 0°C to +60°C range.

  • Legacy Turbine Installations: Older systems requiring both T/C and RTD monitoring.


Comparison with Related Models

Feature DS3800NHVM1B1A DS3800NHVM (Base) DS3800NHVL1C1C DS3800NHVK1A1A
Relay Current 3A @ 125VDC 3A @ 125VDC 2A @ 125VDC 2A @ 125VDC
Relay Surge 6A 6A 4A 4A
SS Outputs 4 × 3A @ 48VDC 4 × 3A @ 48VDC 4 × 3A @ 48VDC 4 × 3A @ 48VDC
T/C + RTD Inputs 8 + 8 = 16 8 + 8 = 16 4 + 8 = 12 8 + 8 = 16
ADC Resolution 24-bit 24-bit 24-bit 16-bit
Predictive Maintenance Yes Yes Yes No
RTD Fault Detection Yes Yes Yes Yes
Operating Temp 0°C to +60°C -40°C to +75°C -40°C to +75°C 0°C to +60°C
Fault Log 200 events 500 events 500 events Basic
Firmware B A/B C A
Cost Ultra-Premium Ultra-Premium+ Ultra-Premium Very High

Selection Recommendations

  • Choose the DS3800NHVM1B1A if:

    • You need the highest 125VDC relay current (3A) for powerful exhaust fans.

    • You need high-current solid-state outputs (3A @ 48VDC) .

    • You require both thermocouple and RTD inputs (16 total channels).

    • You require tachometer feedback for fan speed verification.

    • You want predictive relay maintenance.

    • You need 24-bit ADC accuracy.

    • You have a climate-controlled environment (0°C to +60°C).

  • Choose the full DS3800NHVM if: You need the same features but with extreme temperature tolerance (-40°C to +75°C) and 500-event logging.

  • Choose the DS3800NHVL1C1C if: You only need 4 thermocouple + 8 RTD inputs (12 channels) with extreme temperature tolerance.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.

  • High-Voltage Hazard: Relay outputs switch 125VDC—lethal voltage present on terminals. Observe all high-voltage safety procedures. Use wiring rated for ≥125VDC.

  • RTD Wiring: Use 3-wire Pt100 RTDs. All three wires must be connected. Open/short circuits trigger RTD Fault LED.

  • RTD Lead Resistance: Use wire with resistance ≤10Ω per lead.

  • DC Polarity (Relay): Relay outputs are DC only—observe correct polarity.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal.

  • Relay Current Limitation: Rated at 3A continuous @ 125VDC. Verify fan current does not exceed this limit.

  • SS Current Limitation: Rated at 3A continuous @ 24–48VDC.

  • Inductive Load Derating (Relay): For inductive fan motors, derate to 2A or use external RC snubbers (rated for 125VDC).

  • No AC Connection: Do not connect AC loads to either output type.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—all advanced features disabled in fallback mode.

  • Firmware Compatibility: The DS3800NHVM1B1A requires Mark V CPU firmware v5.0 or higher for full 24-bit ADC, predictive maintenance, and RTD support. For v4.x, the board reverts to 16-bit mode with no predictive maintenance.

  • Power Supply: Draws 5.5A on +5V rail—a power supply upgrade is mandatory for most installations.

AB 1734-EP24DC
SIEMENS 6ES7195-7HB00-0XA0
EATON PKZM0-1