GE DS3800NGTA1E1D

¥999.00

The DS3800NGTA1E1D is a premium revision of General Electric’s Mark V series Fan/Exhaust Control board. The suffix “1E1D” indicates Revision E firmware with 24-bit ADC (±0.5°C accuracy), extended temperature components (-40°C to +75°C), military-grade vibration tolerance (5g RMS), 5A mechanical relay outputs, and 8 thermocouple input channels—with no tachometer feedback.

The Revision E firmware builds upon the “1D1D” variant by adding predictive thermal modeling and enhanced fault logging (500 events vs. 200), making this the most advanced 5A relay-based fan control board without tachometer feedback in the Mark V lineup.

Category:

Description

Key Technical Parameters

Parameter Specification
Full Model DS3800NGTA1E1D
Power Supply +5V DC @ 3.8A, +15V DC @ 0.7A, -15V DC @ 0.5A
Temperature Inputs 8 thermocouple channels (Type J/K/T, 24-bit ADC, ±0.5°C accuracy)
Fan Outputs 8 mechanical relays, 5A continuous @ 250VAC/30VDC (surge 10A)
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature -40°C to +75°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 500 events
LED Indicators Power, Fan Run (8x amber), Over-Temp Alarm, Relay Degradation, Predictive Model Active, Backplane Active, Bus Fault

Advantages and Distinctive Features

  • Predictive Thermal Modeling (Revision E): Learns cabinet thermal response during 24-hour initial period, reducing temperature overshoot by up to 50%.

  • 5A Mechanical Relays with Predictive Maintenance: Real-time contact resistance monitoring with relay degradation warning.

  • 24-Bit Ultra-High Precision ADC: ±0.5°C accuracy for precise thermal management.

  • Extended Environmental Tolerance: -40°C to +75°C with 5g vibration resistance.

  • 500-Event Fault Log: Expanded memory for comprehensive diagnostics.

  • Silver-Alloy Relay Contacts: Superior resistance to welding and pitting.

  • AC/DC Output Capability: Switches both AC and DC loads.


Typical Application Fields

  • Offshore Oil & Gas Platforms: Extreme temperature and vibration environments.

  • Desert Power Plants: 75°C upper limit.

  • Arctic Compressor Stations: -40°C low-temperature tolerance.

  • Safety-Critical Cooling Systems: Where relay health monitoring and predictive modeling are mandatory.

  • Large Fan Applications: 5A capacity for 1/2 HP AC fans.


Comparison with Related Models

Feature DS3800NGTA1E1D DS3800NGTA1D1D DS3800NGTA (Base) DS3800NFEE1E1E
Relay Current 5A 5A 3A 8A
ADC Resolution 24-bit (±0.5°C) 24-bit (±0.5°C) 12-bit (±2°C) 24-bit (±0.5°C)
Predictive Maintenance Yes Yes No Yes
Predictive Thermal Modeling Yes No No No
Tach Inputs None None None None
Fault Log 500 events 200 events Basic 100 events
Operating Temp -40°C to +75°C -40°C to +75°C 0°C to +60°C -40°C to +75°C
Cost High Premium Low Very High

Selection Recommendations

  • Choose the DS3800NGTA1E1D if:

    • You need 5A relay outputs with ultra-precise temperature monitoring (±0.5°C).

    • You want predictive thermal modeling for proactive temperature management.

    • You require predictive relay maintenance.

    • You need 500-event fault logging.

    • Your installation is in extreme environments (-40°C to +75°C).

    • You do not require tachometer feedback.

  • Choose the DS3800NFEE1E1E if: You need 8A relay outputs with 24-bit ADC.

  • Choose the DS3800NGTA1D1D if: You need 5A relays and predictive maintenance but do not require predictive thermal modeling.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • Relay Derating: For inductive motor loads, derate from 5A to 3.5A or use RC snubbers.

  • No Tachometer Inputs: Do not connect speed sensors.

  • Predictive Model Learning: Requires 24-hour initial learning period—do not interrupt power.

  • Model Reset: Reset via Mark V software if cabinet configuration changes.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—all advanced features disabled in fallback mode.

  • Firmware Compatibility: Revision E requires Mark V CPU firmware v5.5 or higher for full predictive modeling, predictive maintenance, and 24-bit ADC. For v5.0–v5.4, predictive modeling disabled (maintenance and ADC still function). For v4.x, reverts to 16-bit mode.

  • Power Supply: Draws 3.8A on +5V rail—verify sufficient capacity.

Siemens 3VT8320-1AA03-0AA0 3P 200A
YASKAWA JZNC-XIU01B
A-B 1746-IV16

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NGTA1E1D”

Your email address will not be published. Required fields are marked *

Post comment