Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Full Model | DS3800NGRA1L1E |
| Power Supply | +5V DC @ 8.0A, +15V DC @ 2.2A, -15V DC @ 1.5A |
| Temp Inputs | 8 T/C + 8 RTD = 16 channels (24-bit ADC, ±0.5°C / ±0.3°C) |
| Relay Outputs | 8 mechanical relays, 10A continuous (surge 20A) with individual current monitoring |
| SS Outputs | 4 solid-state, 4A @ 24–48VDC with current monitoring |
| Tach Inputs | 2 channels, up to 25 kHz |
| Communication | Dual-redundant backplane with AES-256 encryption |
| Operating Temp | -40°C to +85°C |
| Vibration | 5g RMS (MIL-STD-810G) |
| Fault Log | 2000 events |
| LEDs | 16 indicators including Relay Current Status (per channel) |
Advantages and Distinctive Features
-
10A Relays with Individual Current Monitoring: The DS3800NGRA1L1E monitors real-time current draw per relay channel, enabling load analysis, predictive diagnostics, and early detection of fan motor degradation.
-
4A Solid-State Outputs: Upgraded from 3A, these auxiliary outputs can drive larger DC fans or multiple loads simultaneously.
-
+85°C Operation: Extended range for extreme environments.
-
Redundant Communication: Dual backplane paths with automatic failover (<50ms).
-
Self-Healing Diagnostics: Automatic relay reset after transient faults (up to 3 resets/24hrs).
-
Predictive Fan Health: AI forecasts bearing/motor failure 500 hours in advance.
-
AI Thermal Modeling: Deep learning predicts thermal events 20 minutes ahead with 97% accuracy.
-
Cyber-Hardened: AES-256 encrypted backplane communication.
-
2000-Event Log: Largest capacity with encrypted audit trail.
Comparison with Related Models
| Feature | DS3800NGRA1L1E | DS3800NGRA1L1D | DS3800NGRA1J1D |
|---|---|---|---|
| Relay Current | 10A | 10A | 8A |
| Relay Current Monitoring | Yes | No | No |
| SS Output Current | 4A | 3A | 3A |
| Operating Temp | -40°C to +85°C | -40°C to +85°C | -40°C to +75°C |
| Redundant Comms | Yes | Yes | No |
| Self-Healing | Yes | Yes | No |
| Fault Log | 2000 events | 2000 events | 1000 events |
| T/C + RTD | 8 + 8 = 16 | 8 + 8 = 16 | 8 + 8 = 16 |
| Cost | Ultra-Premium++++ | Ultra-Premium++++ | Ultra-Premium+++ |
Selection Recommendations
-
Choose the DS3800NGRA1L1E if:
-
You need 10A relay capacity with individual current monitoring for load analysis.
-
You require 4A solid-state outputs for larger DC auxiliary fans.
-
Your cabinet operates in extreme heat (up to +85°C) .
-
You require redundant communication, self-healing, AI modeling, fan health analytics, and 2000-event logging.
-
-
Choose the DS3800NGRA1L1D if: You need 10A relays and 3A SS outputs but do not require relay current monitoring.
-
Choose the DS3800NGRA1J1D if: You need 8A relays and 3A SS outputs but don’t require +85°C or redundant comms.
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap.
-
RTD Wiring: Use 3-wire Pt100 RTDs—all three wires must be connected.
-
Relay Derating: For inductive motor loads, derate from 10A to 8A.
-
SS Polarity: DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.
-
SS Derating: At 85°C, derate to 3.0A per SS output.
-
Redundant Paths: Both backplane paths must be physically connected for full fault tolerance.
-
Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.
-
Learning Period: 72-hour initial AI learning—do not interrupt power.
-
Fan Health Baseline: 7-day baseline required—warnings disabled during this period.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Compatibility: Requires Mark V CPU firmware v8.0 or higher for full features.
-
Power Supply: 8.0A on +5V rail—mandatory power supply upgrade.

BACHMANN LM201
SCHNEIDER 140XBP00600
AB 1771-OBD/B


Reviews