GE DS3800NGRA1L1E

¥999.00

The DS3800NGRA1L1E is the ultimate, most advanced revision in GE’s Mark V series Fan/Exhaust Control board family, representing the absolute pinnacle of Speedtronic™ turbine cooling management. The suffix “1L1E” signifies Revision L firmware10A mechanical relays4A solid-state auxiliary outputs16 temperature channels (8 T/C + 8 RTD), 2 tachometer inputs-40°C to +85°C operation, dual-redundant backplane communication, and individual relay current monitoring—a feature introduced by the “1E” suffix.

This board builds upon the DS3800NGRA1L1D by upgrading the solid-state auxiliary outputs from 3A to 4A and adding real-time relay contact current measurement, enabling precise load analysis and predictive diagnostics for each relay channel.

Category:

Description

Key Technical Parameters

Parameter Specification
Full Model DS3800NGRA1L1E
Power Supply +5V DC @ 8.0A, +15V DC @ 2.2A, -15V DC @ 1.5A
Temp Inputs 8 T/C + 8 RTD = 16 channels (24-bit ADC, ±0.5°C / ±0.3°C)
Relay Outputs 8 mechanical relays, 10A continuous (surge 20A) with individual current monitoring
SS Outputs 4 solid-state, 4A @ 24–48VDC with current monitoring
Tach Inputs 2 channels, up to 25 kHz
Communication Dual-redundant backplane with AES-256 encryption
Operating Temp -40°C to +85°C
Vibration 5g RMS (MIL-STD-810G)
Fault Log 2000 events
LEDs 16 indicators including Relay Current Status (per channel)

Advantages and Distinctive Features

  • 10A Relays with Individual Current Monitoring: The DS3800NGRA1L1E monitors real-time current draw per relay channel, enabling load analysis, predictive diagnostics, and early detection of fan motor degradation.

  • 4A Solid-State Outputs: Upgraded from 3A, these auxiliary outputs can drive larger DC fans or multiple loads simultaneously.

  • +85°C Operation: Extended range for extreme environments.

  • Redundant Communication: Dual backplane paths with automatic failover (<50ms).

  • Self-Healing Diagnostics: Automatic relay reset after transient faults (up to 3 resets/24hrs).

  • Predictive Fan Health: AI forecasts bearing/motor failure 500 hours in advance.

  • AI Thermal Modeling: Deep learning predicts thermal events 20 minutes ahead with 97% accuracy.

  • Cyber-Hardened: AES-256 encrypted backplane communication.

  • 2000-Event Log: Largest capacity with encrypted audit trail.


Comparison with Related Models

Feature DS3800NGRA1L1E DS3800NGRA1L1D DS3800NGRA1J1D
Relay Current 10A 10A 8A
Relay Current Monitoring Yes No No
SS Output Current 4A 3A 3A
Operating Temp -40°C to +85°C -40°C to +85°C -40°C to +75°C
Redundant Comms Yes Yes No
Self-Healing Yes Yes No
Fault Log 2000 events 2000 events 1000 events
T/C + RTD 8 + 8 = 16 8 + 8 = 16 8 + 8 = 16
Cost Ultra-Premium++++ Ultra-Premium++++ Ultra-Premium+++

Selection Recommendations

  • Choose the DS3800NGRA1L1E if:

    • You need 10A relay capacity with individual current monitoring for load analysis.

    • You require 4A solid-state outputs for larger DC auxiliary fans.

    • Your cabinet operates in extreme heat (up to +85°C) .

    • You require redundant communicationself-healing, AI modeling, fan health analytics, and 2000-event logging.

  • Choose the DS3800NGRA1L1D if: You need 10A relays and 3A SS outputs but do not require relay current monitoring.

  • Choose the DS3800NGRA1J1D if: You need 8A relays and 3A SS outputs but don’t require +85°C or redundant comms.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • RTD Wiring: Use 3-wire Pt100 RTDs—all three wires must be connected.

  • Relay Derating: For inductive motor loads, derate from 10A to 8A.

  • SS Polarity: DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • SS Derating: At 85°C, derate to 3.0A per SS output.

  • Redundant Paths: Both backplane paths must be physically connected for full fault tolerance.

  • Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.

  • Learning Period: 72-hour initial AI learning—do not interrupt power.

  • Fan Health Baseline: 7-day baseline required—warnings disabled during this period.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Compatibility: Requires Mark V CPU firmware v8.0 or higher for full features.

  • Power Supply: 8.0A on +5V rail—mandatory power supply upgrade.

BACHMANN LM201
SCHNEIDER 140XBP00600
AB 1771-OBD/B

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NGRA1L1E”

Your email address will not be published. Required fields are marked *