Description
Technical Specifications
-
Product Type: Digital Voltage Reference & Calibration Board (Revision 1A1A)
-
Part Number: DS3800DVRC1A1A
-
Manufacturer: General Electric (GE)
-
System Compatibility: GE Speedtronic Mark IV Turbine Control Systems
-
Reference Outputs: 4 precision voltage references (±1V, ±5V, ±10V, and 0-10V)
-
Accuracy: ±0.01% of full scale at 25°C; ±0.002% per °C drift
-
Temperature Stability: < 2ppm/°C (hermetically sealed reference)
-
Long-Term Stability: < 20ppm/year
-
Load Regulation: < 0.005% for 0 to 10mA load
-
Line Regulation: < 0.001% for ±10% input variation
-
Protection: Short-circuit protected outputs
-
Isolation: 2500Vrms reinforced isolation (upgraded)
-
Temperature Range: -40°C to +70°C (extended)
-
MTBF: > 300,000 hours (MIL-HDBK-217F)
Key Features & Advantages
-
Highest Stability Revision: The GE DS3800DVRC1A1A uses hermetically sealed reference components, delivering < 2ppm/°C drift – the best in the DVRC series.
-
Superior Long-Term Stability: < 20ppm/year minimizes recalibration frequency and maintains system accuracy over extended periods.
-
Reinforced Isolation: Upgraded to 2500Vrms, providing better protection against ground loops and voltage transients.
-
Extended Temperature Range: -40°C to +70°C, suitable for outdoor or unheated turbine enclosures.
-
High-Precision References: ±0.01% accuracy, essential for calibrating the Mark IV’s analog-to-digital converters.
-
Four Common Reference Values: Offers ±1V, ±5V, ±10V, and 0-10V.
-
Short-Circuit Protection: Protected outputs prevent damage during calibration setup.
-
Diagnostic LEDs: Front-panel LEDs indicate reference output status.
-
External Test Points: Test points for external voltmeter verification.
Typical Application Cases
-
Analog Input Calibration: Calibrates DS3800DVIA, DS3800DVIA1A1B, and other analog input boards.
-
Analog Output Verification: Verifies accuracy of servo driver and output boards.
-
System Diagnostics: Provides known-good signal source for troubleshooting.
-
Preventive Maintenance: Used during annual calibration checks.
-
Commissioning: Essential for initial startup verification.
Competitive Comparison
| Feature | GE DS3800DVRC1A1A | GE DS3800DVRC1A1 | GE DS3800DVRC1A | External Calibrator |
|---|---|---|---|---|
| Temp Stability | < 2ppm/°C | < 3ppm/°C | < 5ppm/°C | < 1ppm/°C |
| Long-Term Stability | < 20ppm/year | < 30ppm/year | < 50ppm/year | < 10ppm/year |
| Isolation | 2500Vrms | 1500Vrms | 1500Vrms | N/A |
| Temp Range | -40°C to +70°C | 0°C to +65°C | 0°C to +60°C | 0°C to +50°C |
| Accuracy | ±0.01% | ±0.01% | ±0.01% | ±0.001%-0.01% |
| Reference Type | Hermetically sealed | Enhanced | Standard | User-selectable |
The GE DS3800DVRC1A1A is the most stable and environmentally robust revision, preferred for critical applications and harsh environments.
Selection Guidelines & Precautions
-
Reference Verification: Verify outputs with a calibrated external voltmeter before use. If drift is observed, factory recalibration is required.
-
Load Conditions: Accurate only when load current is below 10mA. For higher loads, use external buffer amplifier.
-
Warm-Up Time: Allow the GE DS3800DVRC1A1A to stabilize for at least 30 minutes after power-up before performing critical calibrations.
-
Short-Circuit: While protected, prolonged shorting may degrade accuracy.
-
Calibration Interval: GE recommended recalibration every 2-3 years due to improved stability. Send to qualified calibration lab.
-
ESD Handling: Use ESD-safe practices; contains precision reference components.
-
Sourcing: Obsolete. Request functional test report including:
-
All 4 reference outputs verified for accuracy (±0.01%)
-
Temperature drift test (< 2ppm/°C)
-
Load regulation test (< 0.005%)
-
Isolation verification (2500Vrms)
-
Long-term stability test (if available)
-
-
Spare Strategy: Keep one spare GE DS3800DVRC1A1A on-site. For critical sites, consider NIST-traceable external calibrator as backup.