GE DS200TCCAG1A

¥999.00

The DS200TCCAG1A is a Thermocouple Input Termination Board manufactured by General Electric (GE) as part of the Mark V DS200 series for turbine control systems. This board serves as a specialized termination interface for thermocouple sensors, providing organized, high-density field wiring connections with integrated cold-junction compensation (CJC). The “G1A” suffix denotes a specific revision with 8 thermocouple input channels, integrated CJC, and enhanced labeling for accurate temperature measurement. The DS200TCCAG1A is designed for applications requiring precise temperature monitoring from thermocouple sensors—such as exhaust gas temperature (EGT), bearing temperature, and process temperature measurements—in gas and steam turbine control systems. Unlike general-purpose termination boards (TBS series), the DS200TCCAG1A is specifically optimized for thermocouple signals with onboard CJC for measurement accuracy.

Category:

Description

Technical Parameters

Based on the Mark V DS200 series specifications, the DS200TCCAG1A features the following key parameters:

  • Primary Function: Thermocouple Input Termination Board with Cold-Junction Compensation

  • Input Channels: 8 thermocouple input channels

  • Thermocouple Types Supported: J, K, T, E, S, R (configurable)

  • Cold-Junction Compensation: Onboard high-accuracy thermistor (CJC) with ±0.5°C accuracy typical

  • Input Impedance: >1 MΩ

  • Terminal Type: Screw-type terminal blocks (accepts 0.5-2.5mm² wire, AWG 20-14)

  • Voltage Rating: 300V AC/DC maximum

  • Current Rating: 10A per terminal (maximum)

  • Isolation: No active isolation (passive termination); relies on connected modules for isolation

  • Form Factor: Single-slot 6U Eurocard (160mm), 96-pin DIN connector to backplane

  • Mounting: Direct plug-in to Mark V rack; front-facing screw terminals for thermocouple wiring

  • Operating Environment: 0°C to 60°C ambient temperature, 5% to 95% non-condensing humidity

  • Labels: Enhanced labeling with clearly marked channel designations (CH+, CH-) and type selection guides

  • Compliance: UL recognized, CE marked

Advantages and Features

The DS200TCCAG1A offers several distinctive advantages for Mark V system thermocouple signal termination:

  1. Integrated Cold-Junction Compensation: The onboard CJC thermistor ensures accurate temperature readings by compensating for ambient temperature variations at the DS200TCCAG1A termination point.

  2. Multi-Type Support: Supports thermocouple Types J, K, T, E, S, and R, allowing flexible sensor selection.

  3. High-Density Termination: With 8 dedicated thermocouple channels, the DS200TCCAG1A provides efficient termination for multiple sensors in a single slot.

  4. Enhanced Labeling: The “A” revision features improved labeling for easier identification and reduced wiring errors.

  5. Screw-Type Terminals: Accepts solid or stranded thermocouple wire (0.5-2.5mm²), ensuring secure connections.

  6. Passive Design: Contains no active electronics (other than CJC thermistor), making the DS200TCCAG1A highly reliable.

  7. Direct Rack Integration: Plugs directly into the Mark V backplane.

  8. Hot-Swap Capable: Supports live insertion and removal with proper ESD protocols.

Application Cases in Application Fields

The DS200TCCAG1A is deployed across multiple heavy-industrial sectors:

  • Combined Cycle Power Plants: A 750MW CCPP facility uses multiple DS200TCCAG1A boards to terminate exhaust thermocouple sensors for temperature spread monitoring, with the onboard CJC ensuring accurate readings critical for turbine efficiency and protection.

  • Steam Turbine Retrofits: During a control system refurbishment, a facility installed the DS200TCCAG1A for main steam and reheat temperature monitoring with J and K-type thermocouples.

  • Gas Pipeline Compressor Stations: The DS200TCCAG1A terminates thermocouples for compressor discharge temperature monitoring, providing critical inputs for surge protection.

  • Offshore Oil Platforms: The robust screw-terminal design of the DS200TCCAG1A has proven reliable in high-vibration offshore environments.

Comparison with Competing Products

Aspect DS200TCCAG1A General-Purpose TBSAG1A Third-Party Thermocouple Board
Thermocouple-Specific Yes (with CJC) No Varies
Cold-Junction Compensation Onboard (±0.5°C) None Varies; often requires external
Channel Count 8 channels 16 channels (mixed) Varies; often 4-8 channels
Thermocouple Types J, K, T, E, S, R N/A Varies; often limited
Terminal Type Screw-type Screw-type Varies
Rack Integration Direct plug-in Direct plug-in Requires external mounting
Hot-Swap Capable Yes Yes Usually no
Passive Design Yes (plus CJC) Yes Varies

Selection Suggestions and Precautions

Before purchasing or installing the DS200TCCAG1A:

  • Verify Exact Model: Ensure the board is precisely DS200TCCAG1A, not DS200TCCAG1 or DS200TCCAG1B. The “A” suffix indicates enhanced labeling.

  • Confirm Thermocouple Types: Ensure your thermocouple types (J, K, T, E, S, R) are supported by the DS200TCCAG1A.

  • Thermocouple Wiring: Use correct thermocouple extension wire (same type as sensor). Avoid standard copper wire for extensions.

  • Polarity: Ensure correct polarity (positive and negative leads) when terminating to the DS200TCCAG1A.

  • Shielding: Use shielded thermocouple cables in electrically noisy environments. Connect the shield at the DS200TCCAG1A end only.

  • CJC Stability: The CJC thermistor measures ambient temperature. Ensure adequate airflow around the DS200TCCAG1A and avoid mounting near heat sources to maintain CJC accuracy.

  • ESD Protection: Use grounded wrist straps during handling.

  • Post-Installation Validation:

    • Verify all terminations are mechanically secure.

    • Confirm correct polarity and sensor type for each channel.

    • Check CJC readings against a known ambient temperature reference.

    • Verify temperature readings at the HMI match expected values.

  • Spare Strategy: Maintain at least one spare DS200TCCAG1A on-site.

  • Supplier Qualification: Request visual inspection and CJC accuracy verification before shipment.

Final Recommendation

For GE Mark V turbine systems requiring dedicated thermocouple input termination with integrated cold-junction compensation, the DS200TCCAG1A is the essential solution. Its 8-channel capacity, multi-type support, onboard CJC, and robust screw-terminals provide accurate, reliable thermocouple signal routing for critical temperature monitoring applications. Prioritize reputable aftermarket suppliers offering tested units with CJC accuracy verification. Maintain spares on-site, use correct thermocouple extension wire, and ensure proper polarity to guarantee the long-term reliability of your DS200TCCAG1A and the entire Mark V control system.

BENTLY 330500-02-00
FOXBORO FBM203
FOXBORO FBM215
FOXBORO FBM202

Reviews

There are no reviews yet.

Be the first to review “GE DS200TCCAG1A”

Your email address will not be published. Required fields are marked *

Post comment