Description
Technical Parameters
Based on the Mark V DS200 series specifications, the DS200TCCAG1A features the following key parameters:
-
Primary Function: Thermocouple Input Termination Board with Cold-Junction Compensation
-
Input Channels: 8 thermocouple input channels
-
Thermocouple Types Supported: J, K, T, E, S, R (configurable)
-
Cold-Junction Compensation: Onboard high-accuracy thermistor (CJC) with ±0.5°C accuracy typical
-
Input Impedance: >1 MΩ
-
Terminal Type: Screw-type terminal blocks (accepts 0.5-2.5mm² wire, AWG 20-14)
-
Voltage Rating: 300V AC/DC maximum
-
Current Rating: 10A per terminal (maximum)
-
Isolation: No active isolation (passive termination); relies on connected modules for isolation
-
Form Factor: Single-slot 6U Eurocard (160mm), 96-pin DIN connector to backplane
-
Mounting: Direct plug-in to Mark V rack; front-facing screw terminals for thermocouple wiring
-
Operating Environment: 0°C to 60°C ambient temperature, 5% to 95% non-condensing humidity
-
Labels: Enhanced labeling with clearly marked channel designations (CH+, CH-) and type selection guides
-
Compliance: UL recognized, CE marked
Advantages and Features
The DS200TCCAG1A offers several distinctive advantages for Mark V system thermocouple signal termination:
-
Integrated Cold-Junction Compensation: The onboard CJC thermistor ensures accurate temperature readings by compensating for ambient temperature variations at the DS200TCCAG1A termination point.
-
Multi-Type Support: Supports thermocouple Types J, K, T, E, S, and R, allowing flexible sensor selection.
-
High-Density Termination: With 8 dedicated thermocouple channels, the DS200TCCAG1A provides efficient termination for multiple sensors in a single slot.
-
Enhanced Labeling: The “A” revision features improved labeling for easier identification and reduced wiring errors.
-
Screw-Type Terminals: Accepts solid or stranded thermocouple wire (0.5-2.5mm²), ensuring secure connections.
-
Passive Design: Contains no active electronics (other than CJC thermistor), making the DS200TCCAG1A highly reliable.
-
Direct Rack Integration: Plugs directly into the Mark V backplane.
-
Hot-Swap Capable: Supports live insertion and removal with proper ESD protocols.
Application Cases in Application Fields
The DS200TCCAG1A is deployed across multiple heavy-industrial sectors:
-
Combined Cycle Power Plants: A 750MW CCPP facility uses multiple DS200TCCAG1A boards to terminate exhaust thermocouple sensors for temperature spread monitoring, with the onboard CJC ensuring accurate readings critical for turbine efficiency and protection.
-
Steam Turbine Retrofits: During a control system refurbishment, a facility installed the DS200TCCAG1A for main steam and reheat temperature monitoring with J and K-type thermocouples.
-
Gas Pipeline Compressor Stations: The DS200TCCAG1A terminates thermocouples for compressor discharge temperature monitoring, providing critical inputs for surge protection.
-
Offshore Oil Platforms: The robust screw-terminal design of the DS200TCCAG1A has proven reliable in high-vibration offshore environments.
Comparison with Competing Products
| Aspect | DS200TCCAG1A | General-Purpose TBSAG1A | Third-Party Thermocouple Board |
|---|---|---|---|
| Thermocouple-Specific | Yes (with CJC) | No | Varies |
| Cold-Junction Compensation | Onboard (±0.5°C) | None | Varies; often requires external |
| Channel Count | 8 channels | 16 channels (mixed) | Varies; often 4-8 channels |
| Thermocouple Types | J, K, T, E, S, R | N/A | Varies; often limited |
| Terminal Type | Screw-type | Screw-type | Varies |
| Rack Integration | Direct plug-in | Direct plug-in | Requires external mounting |
| Hot-Swap Capable | Yes | Yes | Usually no |
| Passive Design | Yes (plus CJC) | Yes | Varies |
Selection Suggestions and Precautions
Before purchasing or installing the DS200TCCAG1A:
-
Verify Exact Model: Ensure the board is precisely DS200TCCAG1A, not DS200TCCAG1 or DS200TCCAG1B. The “A” suffix indicates enhanced labeling.
-
Confirm Thermocouple Types: Ensure your thermocouple types (J, K, T, E, S, R) are supported by the DS200TCCAG1A.
-
Thermocouple Wiring: Use correct thermocouple extension wire (same type as sensor). Avoid standard copper wire for extensions.
-
Polarity: Ensure correct polarity (positive and negative leads) when terminating to the DS200TCCAG1A.
-
Shielding: Use shielded thermocouple cables in electrically noisy environments. Connect the shield at the DS200TCCAG1A end only.
-
CJC Stability: The CJC thermistor measures ambient temperature. Ensure adequate airflow around the DS200TCCAG1A and avoid mounting near heat sources to maintain CJC accuracy.
-
ESD Protection: Use grounded wrist straps during handling.
-
Post-Installation Validation:
-
Verify all terminations are mechanically secure.
-
Confirm correct polarity and sensor type for each channel.
-
Check CJC readings against a known ambient temperature reference.
-
Verify temperature readings at the HMI match expected values.
-
-
Spare Strategy: Maintain at least one spare DS200TCCAG1A on-site.
-
Supplier Qualification: Request visual inspection and CJC accuracy verification before shipment.
Final Recommendation
For GE Mark V turbine systems requiring dedicated thermocouple input termination with integrated cold-junction compensation, the DS200TCCAG1A is the essential solution. Its 8-channel capacity, multi-type support, onboard CJC, and robust screw-terminals provide accurate, reliable thermocouple signal routing for critical temperature monitoring applications. Prioritize reputable aftermarket suppliers offering tested units with CJC accuracy verification. Maintain spares on-site, use correct thermocouple extension wire, and ensure proper polarity to guarantee the long-term reliability of your DS200TCCAG1A and the entire Mark V control system.

BENTLY 330500-02-00
FOXBORO FBM203
FOXBORO FBM215
FOXBORO FBM202


Reviews
There are no reviews yet.