Description
Parameters
-
Input Type: 24V DC discrete (sourcing/sinking, configurable)
-
Input Channels: 24 channels (higher density than HLIA’s 16)
-
Input Voltage: 24V DC (nominal), 10–30V DC range
-
Input Current: 5mA per channel (typical)
-
Response Time: <0.4ms (B1 optimized, faster than A1’s <0.5ms)
-
Hardware Latch: Yes – captures short-duration pulses (<1ms) with B1 improved timing accuracy
-
Isolation: 2500V RMS optical isolation (channel-to-backplane)
-
Power: +5V DC @ 0.9A, +24V DC @ 0.3A (field power)
-
Filtering: Programmable input debounce filter with 50Hz/60Hz noise rejection (B1 feature)
-
Coating: Conformal coating (suffix C) – medium-thickness acrylic with improved humidity and mild chemical resistance
-
Temp Range: -10°C to +65°C (extended, enabled by C coating)
-
Mounting: 6U VME Eurocard, single-slot
-
Diagnostics: Enhanced onboard with per-channel LED status, open-wire detection, short-circuit protection, signal noise alert, and latch event logging (B1 feature)
Advantages & Features
-
Higher channel density – 24 high-speed inputs on a single board, more than HLIA’s 16 channels
-
Ultra-fast response (<0.4ms) – the fastest discrete input response, designed for the most critical protection logic
-
Hardware latch capability – captures short-duration pulses with improved timing accuracy from B1 firmware
-
B1 firmware offers improved filtering, 50/60Hz noise rejection, and enhanced diagnostics including latch event logging – a significant upgrade over A1
-
Flexible input configuration – channels can be set as sourcing or sinking via jumpers
-
C-grade coating provides moderate moisture and dust protection compared to B – suitable for indoor environments with occasional humidity
-
Extended temperature range (-10°C to +65°C) offers more flexibility than B variant
-
Front-panel LEDs for per-channel status, fault, open-wire detection, and signal noise alerts
-
Compatible with Mark IV backplanes and some VIe systems (with adapter)
Application Cases
-
Overspeed protection – ultra-fast magnetic pickup sensor inputs for turbine overspeed trip logic with multiple sensors in moderately humid environments
-
Flame detection – high-speed UV/IR flame scanner signals for burner management across multiple zones with latch event logging
-
Emergency trip systems (ETS) – critical discrete inputs for emergency shutdown logic with high channel count
-
Turbine start-up sequencing – fast-response speed and position sensors
-
Retrofit projects upgrading from A1 firmware for faster response, noise rejection, and improved diagnostics
Competitor Comparison
-
vs. DS3800HLIC1A1B (A1/B variant): Faster response (<0.4ms vs. <0.5ms), B1 noise rejection, enhanced diagnostics, and C coating (vs. B) – significant upgrade
-
vs. DS3800HLIA1A1B (A1/B variant): More input channels (24 vs. 16), faster response, B1 diagnostics, and C coating – major upgrade
-
vs. DS3800HLIA1B1D (B1/D variant): HLIC1B1C offers more channels (24 vs. 16) but has C coating (vs. D) – choose based on channel density vs. coating level
-
vs. DS3800HLEA1C1C (input-only high-speed): HLIC1B1C offers faster response (<0.4ms vs. <0.6ms), hardware latch capability, and higher channel density (24 vs. 16) – HLIC is for critical protection applications
-
vs. DS3800HLCA (hybrid I/O): HLIC1B1C is input-only with faster response (<0.4ms vs. <1ms) and hardware latch – better for critical protection
-
vs. DS3800HHRB1D1D (standard discrete I/O): HLIC1B1C offers significantly faster response (<0.4ms vs. 3ms) – critical for high-speed protection
-
vs. ABB DSDI series: Similar high-speed discrete capability, but GE offers faster response, higher density, hardware latch, and C coating
-
vs. Siemens 6ES7 series: Similar functionality, but GE offers faster response, higher channel density, B1 diagnostics, and hardware latch
-
vs. Woodward 5437 modules: GE offers faster response, higher density, hardware latch, and C-grade coating
Selection Suggestions
-
Critical: Confirm input type (sourcing vs. sinking) – jumper settings must match your field devices
-
Critical: Verify response time requirement – HLIC1B1C’s <0.4ms is for the most critical protection
-
Verify your backplane provides both +5V and +24V field power with sufficient current capacity (+24V @ 0.3A)
-
Assess channel count – 24 channels cover larger monitoring applications with multiple high-speed sensors
-
Evaluate if B1’s latch event logging and noise rejection are beneficial – particularly valuable for critical protection applications requiring post-event analysis
-
Evaluate environmental conditions – C coating is suitable for moderate humidity and light chemical exposure; choose D/G/H for more demanding conditions
-
Order mating front connector (p/n may vary – confirm with GE)
-
For critical protection applications, purchase with a calibration certificate and 12-month warranty
Precautions
-
Critical: Do not exceed 30V DC on input channels – overvoltage may damage the isolation circuits
-
Critical: High-speed inputs (<0.4ms) are extremely sensitive to noise – use shielded twisted-pair cables, proper grounding, and dedicated field wiring to avoid false triggers; B1’s noise rejection helps but is not a substitute for good wiring practices
-
Critical: Hardware latch capability requires proper configuration – ensure the latch settings match your application requirements to avoid missing pulses or false captures
-
Ensure field power supply (+24V DC) is stable and within 10–30V DC range
-
B1 firmware offers improved filtering – configure debounce settings correctly for your sensor type; for critical protection, very short debounce delays (or none) may be needed
-
C coating provides moderate protection but is not suitable for direct salt spray, heavy chemical exposure, or continuous condensation – upgrade to D/G/H for those conditions
-
Allow 30–45 minute warm-up before commissioning (C coating affects thermal equilibrium)
-
Store in ESD-safe packaging – edge connector is static-sensitive
-
Periodically verify input operation every 6 months (critical protection circuits require frequent testing)
-
Do not hot-swap – Mark IV backplanes require power-off for insertion/removal
-
If replacing multiple lower-density boards, verify wiring and pinout compatibility – HLIC may differ from HLIA in pin assignments
-
C coating may make component-level repairs difficult – consider board replacement instead of repair

A-B 1756-IB32/B
A-B 1756-IB32/B
SIEMENS 6EP1935-6MD11