Description
Product Description
The ALSTOM LE109A-1 is a robust and versatile logic module from the Alstom (now part of GE Vernova) automation portfolio, specifically designed for implementing hardwired safety interlocks, permissive logic, and critical sequencing functions independent of a central PLC. As a Logic Element (LE) module, the ALSTOM LE109A-1 provides a reliable, hardware-based solution for applications where deterministic response, fail-safe operation, and protection against software or communication failures are paramount. It functions by processing discrete input signals from devices like limit switches, pressure transmitters, and emergency stops, and executing predefined logical operations to control output relays that command contactors, solenoid valves, or alarm annunciators.
Product Parameters
-
Model: ALSTOM LE109A-1.
-
Function: Hardwired Logic Element / Safety Interlock Module.
-
Input Channels: Typically features multiple, isolated DC voltage input channels (e.g., 4, 8, or 12 channels) for accepting signals from field devices.
-
Output Channels: Equipped with an equivalent number of relay outputs (normally open/closed contacts) rated for switching AC/DC loads (e.g., 5A at 250V AC).
-
Logic Configuration: Implements fixed or configurable logic gates (AND, OR, NOT) internally. Configuration is often done via internal jumper links or a simple programming interface, not software.
-
Power Supply: Operates on a standard control voltage, commonly 24V DC or 110V DC.
-
Response Time: Provides extremely fast, millisecond-range response time, independent of any network or PLC scan cycle.
-
Isolation: High electrical isolation between input, output, and power supply sections to prevent fault propagation.
-
Fail-Safe State: Typically designed to de-energize outputs upon loss of input power or module failure, driving the controlled process to a predefined safe state.
-
Mounting: Standard DIN-rail mountable design for easy installation in control enclosures.
Advantages and Features
-
Ultra-High Reliability and Determinism: As a dedicated hardware device, the ALSTOM LE109A-1 offers predictable and failsafe operation, completely immune to software bugs, network latency, or PLC processor faults.
-
Fail-Safe Design Philosophy: Engineered so that any internal fault or loss of power results in a de-energized (safe) output state, which is a fundamental principle in safety system design.
-
Excellent Noise Immunity: The hardened design and isolation provide superior resistance to electromagnetic interference (EMI) and voltage transients common in industrial environments, preventing nuisance trips.
-
Ease of Understanding and Maintenance: The logic is implemented in a clear, hardwired manner that is easily understood and verified by electricians and technicians, simplifying troubleshooting and compliance audits.
-
Independent Safety Layer: Can be used to create a safety interlock system that is physically and logically separate from the basic process control system (BPCS), providing a crucial layer of independent protection.
Application Cases in Relevant Fields
-
Turbine and Compressor Safety Sequencing: The ALSTOM LE109A-1 is used to implement hardwired permissive logic for large rotating equipment, such as ensuring lube oil pressure is adequate before allowing a turbine start command to proceed.
-
Machine Guarding and Emergency Stop (E-Stop) Circuits: Forms the core logic for safety relays in industrial machinery, ensuring that opening a safety gate or pressing an E-stop immediately and reliably removes power from dangerous actuators.
-
Burner Management System (BMS) Safety Logic: Used for critical fuel valve sequencing and flame safeguard logic in boiler systems, where a hardware-based solution is often mandated by safety standards.
-
Critical Pump and Fan Interlocks: Provides reliable interlocking between related pieces of equipment, such as preventing a pump from starting if its associated suction valve is not verified as open.
Comparisons with Competing Products
Compared to using a safety-rated PLC (e.g., Siemens F-series, Rockwell GuardLogix) or a generic safety relay (e.g., Pilz, Sick), the ALSTOM LE109A-1 occupies a specific niche.
-
Simplicity vs. Flexibility: The ALSTOM LE109A-1 is simpler and often more cost-effective for a fixed, well-defined interlock function than a configurable safety PLC. However, a safety PLC offers far greater flexibility for complex logic and integration.
-
OEM System Integration: In systems already built around Alstom/GE control components, the ALSTOM LE109A-1 offers a consistent form factor and known performance characteristics that may be preferred for auxiliary safety functions.
-
Verification and Certification: Its fixed logic can be easier to validate for specific safety functions than a programmed PLC, though certified safety relays come with pre-certified function blocks. For a straightforward, hardware-based interlock within a compatible ecosystem, the ALSTOM LE109A-1 is a robust and reliable choice.
Selection Suggestions and Precautions
-
Clearly Define the Safety Function: Document the exact interlock logic (e.g., “Output Y energizes ONLY if Input A AND Input B are active”) before selecting and wiring the ALSTOM LE109A-1.
-
Verify Voltage Ratings Precisely: Match the input signal voltage (e.g., 24V DC from a limit switch) and the output contact rating (voltage and current for the solenoid/contactor) exactly with the module’s specifications.
-
Understand the Internal Logic Diagram: Obtain and follow the manufacturer’s wiring and configuration diagram for the ALSTOM LE109A-1. Incorrect jumpering or wiring will result in improper operation.
-
Source from Authorized Safety Component Suppliers: Purchase from GE Vernova authorized distributors or certified suppliers of industrial safety equipment. The reliability of a safety circuit is paramount.
-
Implement with Redundancy if Required: For higher Safety Integrity Level (SIL) requirements, a single ALSTOM LE109A-1 may not be sufficient. Consult safety standards (e.g., IEC 62061, IEC 61511) to determine if redundant or diverse components are needed.
-
Test the Complete Loop Regularly: After installation, perform rigorous functional testing by simulating all normal and fault conditions to verify the ALSTOM LE109A-1 responds correctly. Establish a periodic test schedule to ensure ongoing reliability. Never bypass a safety interlock for operational convenience.

1747-L553 GE
1746-BAS GE
HIEE300936R0101 GE
3BHB000652R0101 GE
PM511V16 GE DCS
ASFC-01C GE DCS
AO845A GE
MP3-11W GE


Reviews