531X140CCHATM2 GE

¥999.00

GE 531X140CCHATM2 is a DC link choke/filter board assembly for GE DC-300, AC-300, and AF-300 drive platforms. It smooths DC bus ripple, suppresses harmonics, and protects IGBT modules. The “TM2” suffix indicates a revised thermal management design with upgraded temperature sensing compared to the “SM2” variant.

Category:

Description

Technical Parameters

  • Inductance: 0.8 – 1.8 mH (matched to 200–500 HP drives)

  • Current: 250 – 450 A continuous (forced-air cooled)

  • Capacitance: 1200 – 2400 µF total (900 VDC film caps)

  • Bleeder resistors: Two 15 kΩ / 75 W

  • Thermal switch: 130°C normally-closed (higher trip point than SM2)

  • Connectors: 12-pin ribbon (J1) + DC bus bars

  • Mounting: 4× M6 holes (254 × 178 mm pattern)


Advantages & Features

  • Higher thermal threshold – 130°C trip point on GE 531X140CCHATM2 allows continuous operation in higher ambient temperatures

  • Plug-and-play – No tuning needed; pre-calibrated for GE drive control loops

  • Robust surge handling – Low-ESR film capacitors withstand regenerative braking transients

  • Field-serviceable – Through-hole components enable easy capacitor/resistor replacement

  • Extended IGBT life – Superior ripple attenuation reduces switching stress


Application Cases

  • Steel rolling mills – Used in 400 HP AC-300 drives; TM2 version reduced nuisance overtemperature trips in hot summer conditions

  • Mining hoists – GE 531X140CCHATM2 provided reliable filtering at 55°C ambient where SM2 boards frequently tripped

  • Paper mills – Retrofit from SM2 to TM2 eliminated thermal derating events during continuous heavy-load production runs


Competitive Comparison

Aspect GE 531X140CCHATM2 (OEM) Generic Aftermarket Choke
Thermal trip 130°C with drive logic integration None or external only
Tuning Pre-matched, zero setup Requires manual calculation
Mounting Exact pattern, 15-min install Custom brackets needed
Cost Higher upfront, lower TCO Cheaper but higher downtime risk

Selection Suggestions

  • Confirm your drive’s regulator board supports the TM2 thermal profile (check 531X111PSH or 531X139 firmware)

  • Verify frame size (Frame 6, 7, or 8) before ordering GE 531X140CCHATM2

  • For hot environments, choose TM2 over SM2 for the higher trip point

  • Prefer remanufactured units with new capacitors installed


Precautions

  • Always discharge the DC bus (wait 5+ minutes) before handling GE 531X140CCHATM2

  • Do not operate without forced airflow – the 130°C trip is a safety limit, not a normal operating target

  • Torque bus-bar bolts to 8–10 N·m – over-tightening cracks the PCB

  • Replace all film capacitors if the board has been in storage > 5 years

  • Check IGBT modules for shorts before installing a replacement GE 531X140CCHATM2 – the choke often fails due to downstream faults, not age

  • TM2 is not backward compatible with SM2 in all drives – verify the thermal input configuration in your drive parameters before installation

A-B 1756-A13
HONEYWELL MC-TAIH02
AB 100S-D115ED22C

Reviews

There are no reviews yet.

Be the first to review “531X140CCHATM2 GE”

Your email address will not be published. Required fields are marked *

Post comment