Woodward 9907-1200

¥9,999.00

The 9907-1200 from WOODWARD is a digital governor in the 9907 series of turbine and prime mover controls, designated as the 9907-1200. The 9907-1200 is a microprocessor-based speed and load control unit designed to govern steam turbines, gas turbines, and other prime movers in power generation and industrial drive applications. This 9907-1200 accepts speed signals from magnetic pickups or proximity probes, drives actuator outputs for steam or fuel valves, and supports isochronous and droop control modes for both standalone and paralleled operation. The 9907-1200 includes configurable analog and discrete I/O for auxiliary monitoring, protective trips, and remote control interfaces, making it suitable for a wide range of turbine control architectures. As part of the WOODWARD 9907 family, the 9907-1200 is engineered for continuous duty in power plant and industrial control cabinets, with robust electrical isolation and EMC protection. The 9907-1200 is configured and diagnosed through WOODWARD’s service tools, allowing engineers to tailor governor dynamics, droop settings, and protection setpoints to each prime mover.

Category:

Description

Product Parameters

Parameter Specification
Model 9907-1200
Series 9907
Function Digital governor for turbines and prime movers
Speed Input Magnetic pickup and proximity probe inputs
Control Modes Isochronous and droop control
Actuator Output Configurable current output for steam/fuel valve actuators
Discrete I/O Configurable discrete inputs and relay outputs
Analog I/O Configurable analog inputs for load and auxiliary signals
Communication Serial communication port for configuration and monitoring
Power Supply 24 V DC nominal (per nameplate rating)
Mounting Panel or cabinet mounting
Operating Temperature Industrial range for plant cabinets
Isolation Galvanic isolation on I/O channels
Configuration WOODWARD service tool / PC-based configuration
Diagnostics Status indicators and configurable fault annunciation

Advantages and Features

  • Turbine-specific control: The 9907-1200 is designed specifically for turbine governing, with control algorithms tuned for steam and gas turbine dynamics.

  • Multiple control modes: Isochronous and droop modes allow the 9907-1200 to serve both islanded and paralleled generation applications.

  • Flexible I/O configuration: Configurable analog and discrete channels adapt the 9907-1200 to different turbine and switchgear arrangements.

  • Robust electrical isolation: Galvanically isolated I/O protects the 9907-1200 from ground loops and electrical noise common in power plant environments.

  • Proven WOODWARD platform: The 9907 series builds on WOODWARD’s long experience in turbine governing and power generation control.

  • Comprehensive protection logic: Configurable overspeed, underspeed, and auxiliary trip functions protect the turbine and generator.

Application Cases in Application Fields

  • Steam turbine generators: Speed governing and load control for industrial and utility steam turbine packages using the 9907-1200.

  • Gas turbine packages: Speed control and synchronization for small industrial gas turbine-generator sets with the 9907-1200.

  • Cogeneration plants: Load control between turbines and other prime movers in combined heat and power installations.

  • Industrial drive turbines: Governing of mechanical drive turbines in process plants.

  • Islanded power systems: Frequency and load control for isolated generation systems using the 9907-1200.

Comparison with Competing Products

Feature WOODWARD 9907-1200 Typical Competitor A Typical Competitor B
Turbine-specific algorithms Yes General-purpose governor Yes
Control modes Isochronous, droop Isochronous, droop Isochronous, droop, load share
I/O configurability Flexible analog + discrete Fixed I/O Partially configurable
Galvanic isolation Yes, on I/O channels Partial Yes
Protection logic Configurable trips Basic overspeed Basic overspeed
Configuration tool WOODWARD service tool Vendor-specific Vendor-specific

The 9907-1200 distinguishes itself through turbine-specific control algorithms and a flexible, isolated I/O mix suited to demanding power plant environments.

Selection Suggestions and Precautions

  • Confirm actuator compatibility: Verify that the actuator output of the 9907-1200 matches the current and voltage requirements of your steam or fuel valve actuator.

  • Verify power supply rating: Check the nameplate for the exact supply voltage and tolerance of the 9907-1200 and provide a regulated, filtered supply.

  • Speed signal quality: Ensure the magnetic pickup or proximity probe mounting, tooth count, and cable shielding meet WOODWARD requirements to avoid speed signal noise on the 9907-1200.

  • Configuration backup: Save the configuration file of the 9907-1200 after commissioning so it can be restored after service or replacement.

  • Protection setpoint review: Validate all overspeed, underspeed, and trip setpoints against turbine manufacturer limits during commissioning.

  • Steam valve characterization: Confirm the valve stroke and gain settings match the 9907 configuration for stable control.

  • Spare parts: Given the specialized configuration of the 9907-1200, consider stocking a spare unit or ensuring access to WOODWARD service support for critical installations.

  • Firmware and tool version: Confirm the service tool version is compatible with the firmware revision of the 9907-1200 before deployment.

Reviews

There are no reviews yet.

Be the first to review “Woodward 9907-1200”

Your email address will not be published. Required fields are marked *

Post comment